Impact of Baydur Ratio Correction on the Reliability of Esophageal Pressure Measurement
Authors:
- Andrea RestivoARAndrea Restivo
- Michele Delle VerginiMVMichele Delle Vergini
- Timothy G. GaultonTGTimothy G. Gaulton
- Glasiele AlcalaGAGlasiele Alcala
- Davide Raimondi CominesiDCDavide Raimondi Cominesi
- Sarah E. GerardSGSarah E. Gerard
- Rehab KhalidRKRehab Khalid
- Rajiv GuptaRGRajiv Gupta
- Lorenzo BerraLBLorenzo Berra
Open Access
- 7 July 2026
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 141 (2) , 423-432
Abstract
Tidal changes in esophageal pressure (ΔPes) are used as a surrogate for pleural pressure changes (ΔPpl) to assess chest wall mechanics. The Baydur ratio evaluates pressure transmission and guides catheter positioning. The effects of correcting ΔPes using the Baydur ratio on the accuracy of ΔPpl estimation and its dependence on ventilation mode, spontaneous inspiratory effort, and body position, remain unclear. In ten pigs, ΔPpl was measured using intrapleural balloon catheters, while Pes was recorded at three esophageal locations in supine and prone positions. Animals underwent controlled and assisted ventilation. Baydur ratios were derived during assisted ventilation and from external chest compressions during controlled ventilation. ΔPes before and after correction was compared with ΔPpl using mixed-effects models and Bland–Altman analysis. Additionally, we quantified the proportion of values with (ΔPes−ΔPpl) ≤ 1 cmH₂O. During assisted ventilation, ΔPes showed good agreement with posterior ΔPpl. Baydur correction improved scaling and association (slope 0.76 vs 0.50; r 0.81 vs 0.79, p<0.01) and increased values within ±1 cmH₂O from 29% to 45% when the Baydur ratio fell outside the accepted range. During controlled ventilation, ΔPes showed weaker association and wider limits of agreement, without improvement after correction. Similar patterns were observed in prone position. ΔPes more accurately reflected posterior ΔPpl during assisted ventilation. Baydur correction improves scaling and association, particularly when the Baydur ratio falls outside the accepted range, but does not improve and may worsen agreement during controlled ventilation.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01HL177025)
- National Heart, Lung, and Blood Institute (R01HL171199)
This publication has 32 references indexed in Scilit:
- Esophageal balloon catheter system identification to improve respiratory effort time features and amplitude determinationPhysiological Measurement, 2024
- Monitoring Lung Injury Severity and Ventilation Intensity during Mechanical VentilationSeminars in Respiratory and Critical Care Medicine, 2022
- Oesophageal balloon positioning by echocardiography to guide positive pressure ventilationJournal of Clinical Monitoring and Computing, 2021
- Esophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectivesIntensive Care Medicine, 2016
- Ventilator-Induced Lung InjuryNew England Journal of Medicine, 2013
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- Validation of esophageal pressure occlusion test after paralysisPediatric Pulmonology, 1994
- Measurement of Pleural Pressure with Esophageal Balloon in Anesthetized HumansAnesthesiology, 1983
- Effects of Anesthesia and Paralysis on Diaphragmatic Mechanics in ManAnesthesiology, 1974
- A METHOD OF ASSESSING THE MECHANICAL PROPERTIES OF LUNGS AND AIR-PASSAGESThe Lancet, 1952