Suna Guo
Suna Guo has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Fan Wang
Hebei Univ, Coll Qual & Tech Supervis, Baoding 071002, Hebei, Peoples R China
2 shared publications Baonan Li
College of Quality and Technical Supervision, Hebei University, Baoding, Hebei 071002, People’s Republic of China
1 shared publicationFan Wang
College of Quality and Technical Supervision, Hebei University 1 , Baoding, Hebei 071002
1 shared publicationHaojie Wang
1 shared publicationHongyang Ren
1 shared publication- Hongyang Ren
College of Quality and Technical Supervision, Hebei University 1 , Baoding, Hebei 071002
1 shared publication
Latest Publications
- Open Access
- 12 November 2026
- Published by AIP Publishing in International Journal of Fluid Engineering
- Vol. 4 (1)
CFD-based dynamic performance investigation of a cylindrical gear flowmeter under step and pulsating flow
Cylindrical gear flowmeters are high-precision positive-displacement instruments widely used in aerospace, chemical engineering, and other fields requiring strict dynamic metering. However, research on their dynamic characteristics under fluctuating flow conditions remains insufficient, and conventional static calibration cannot reflect real operating performance. To address these gaps, this paper takes a DN16 cylindrical gear flowmeter as the research object and proposes a computational fluid dynamics simulation method integrated with a rotation (one degree of freedom) model. The time-varying inlet velocity is controlled by function expressions defined in the built-in C-Expression. Simulations are conducted under step flow and pulsating flow conditions, and the method is validated via real-flow experiments. Results indicate that the flowmeter behaves as a first-order inertial system under step flow. The time constant decreases with increasing step amplitude, and the response lag is more pronounced under negative step excitation. Under pulsating flow, the measured amplitude decays significantly with rising frequency; the maximum attenuation exceeds 70% within 10–50 Hz, and attenuation is more severe at low flow rates. The phase difference increases, up to 140°, with increasing frequency. This study provides a technical foundation for dynamic calibration and error compensation of cylindrical gear flowmeters.
- 12 November 2026
- Published by AIP Publishing in International Journal of Fluid Engineering
- Vol. 4 (1)
Open AccessCFD-based dynamic performance investigation of a cylindrical gear flowmeter under step and pulsating flow
Cylindrical gear flowmeters are high-precision positive-displacement instruments widely used in aerospace, chemical engineering, and other fields requiring strict dynamic metering. However, research on their dynamic characteristics under fluctuating flow conditions remains insufficient, and conventional static calibration cannot reflect real operating performance. To address these gaps, this paper takes a DN16 cylindrical gear flowmeter as the research object and proposes a computational fluid dynamics simulation method integrated with a rotation (one degree of freedom) model. The time-varying inlet velocity is controlled by function expressions defined in the built-in C-Expression. Simulations are conducted under step flow and pulsating flow conditions, and the method is validated via real-flow experiments. Results indicate that the flowmeter behaves as a first-order inertial system under step flow. The time constant decreases with increasing step amplitude, and the response lag is more pronounced under negative step excitation. Under pulsating flow, the measured amplitude decays significantly with rising frequency; the maximum attenuation exceeds 70% within 10–50 Hz, and attenuation is more severe at low flow rates. The phase difference increases, up to 140°, with increasing frequency. This study provides a technical foundation for dynamic calibration and error compensation of cylindrical gear flowmeters.
- 29 July 2026
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 112
Design of a crescent orifice plate flowmeter with erosion resistance and low pressure loss
- 29 July 2026
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 112
Design of a crescent orifice plate flowmeter with erosion resistance and low pressure loss
- 13 March 2026
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 110
Design of turbine flowmeter for non-fully developed flow fields
- 13 March 2026
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 110
Design of turbine flowmeter for non-fully developed flow fields
- 5 August 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (11) , 115303
An adaptive weighted integration method for multipath ultrasonic flowmeter
The error introduced by the integration method is an important factor affecting the measurement accuracy of the multipath ultrasonic flowmeter. An adaptive weighted integration method (adaptive weighted integration method for velocity profile of circular section) is proposed to reduce the integration error, taking a DN400 double-side eight-path ultrasonic flowmeter as an example. This method is based on the velocity distribution information in the full flow range and the integration weights are determined by the principle of minimum error. The applicability of this method is verified by numerical simulation and actual fluid flow experiments. The results show that the integration error of the proposed method is superior to the Gauss–Jacobi and optimized weighted integration method for circular section integration methods, and the maximum integration error is reduced from 0.0877% and −0.0355% to 0.0220% in the flow range of 125–2500 t h−1.
- 5 August 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (11) , 115303
An adaptive weighted integration method for multipath ultrasonic flowmeter
The error introduced by the integration method is an important factor affecting the measurement accuracy of the multipath ultrasonic flowmeter. An adaptive weighted integration method (adaptive weighted integration method for velocity profile of circular section) is proposed to reduce the integration error, taking a DN400 double-side eight-path ultrasonic flowmeter as an example. This method is based on the velocity distribution information in the full flow range and the integration weights are determined by the principle of minimum error. The applicability of this method is verified by numerical simulation and actual fluid flow experiments. The results show that the integration error of the proposed method is superior to the Gauss–Jacobi and optimized weighted integration method for circular section integration methods, and the maximum integration error is reduced from 0.0877% and −0.0355% to 0.0220% in the flow range of 125–2500 t h−1.