Lauren Kline Lovejoy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lauren Kline Lovejoy has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Joe Preston Foley
Department of Chemistry, Drexel University, Philadelphia, USA
2 shared publications
Latest Publications
- 10 March 2026
- Published by Drexel University Libraries
Sequential elution liquid chromatography using ion exchange stationary phases
Sequential Elution Liquid Chromatography (SE-LC) using ion exchange phases is a powerful technique for the separation of complex samples. SE-LC separates analytes by class with multiple elution modes, offering higher peak capacity and reduced separation disorder compared to conventional HPLC, while utilizing standard HPLC instrumentation. An SE-LC method was developed for the separation of permanently charged ions, weak acids, and neutral compounds by employing anion exchange and reversed-phase columns in tandem. Optimization of mobile phase composition, pH, and gradients was critical for effective class-based separation. The finalized method incorporated isocratic elution at low pH to elute the weak acids, followed by an acetonitrile gradient to elute the neutral compounds, and last a sodium methanesulfonate gradient to elute the anionic compounds using a superficially porous C18 column coupled with a strong anion exchange column. High repeatability (RSD < 0.25% for retention time and < 1.5% for peak area) was demonstrated. The above method was validated for quantitative analysis. The validation confirmed its specificity, linearity, accuracy, precision (repeatability), and the flow rate, starting mobile phase organic content, column temperature, mobile phase composition, and gradient start time. The method was demonstrated to be robust, specific, linear, accurate, and precise (repeatable) over the range of 6%-120% of the target analyte range. A second quantitative SE-LC method was developed to separate six pharmaceutical drug product excipients by their classes--amino acids (methionine, arginine, and histidine) and antimicrobial preservatives (sodium benzoate, methylparaben, and propylparaben). This method employed a tandem column setup with a cation exchange column and reversed-phase column (C18) in tandem and utilized a pH gradient to elute the amino acids followed by an acetonitrile gradient to elute the antimicrobial preservatives within 18 minutes. The method was also validated and demonstrated to be specific, linear, accurate, and precise (repeatable) over the range of 50%-150% of the target analyte concentrations. Method robustness was also assessed using a full factorial design of experiments for which the factors investigated were mobile phase concentration, acetonitrile gradient start time and starting percentage of acetonitrile. Based on the factorial results for the experiments, with respect to the relative retention time of the critical pair (sodium benzoate: arginine), the mobile phase concentration and acetonitrile were significant factors that affected the separation. This method could be applied in pharmaceutical laboratories to measure amounts of methionine, arginine, histidine, sodium benzoate, methylparaben, and propylparaben in drug products.
- 10 March 2026
- Published by Drexel University Libraries
Sequential elution liquid chromatography using ion exchange stationary phases
Sequential Elution Liquid Chromatography (SE-LC) using ion exchange phases is a powerful technique for the separation of complex samples. SE-LC separates analytes by class with multiple elution modes, offering higher peak capacity and reduced separation disorder compared to conventional HPLC, while utilizing standard HPLC instrumentation. An SE-LC method was developed for the separation of permanently charged ions, weak acids, and neutral compounds by employing anion exchange and reversed-phase columns in tandem. Optimization of mobile phase composition, pH, and gradients was critical for effective class-based separation. The finalized method incorporated isocratic elution at low pH to elute the weak acids, followed by an acetonitrile gradient to elute the neutral compounds, and last a sodium methanesulfonate gradient to elute the anionic compounds using a superficially porous C18 column coupled with a strong anion exchange column. High repeatability (RSD < 0.25% for retention time and < 1.5% for peak area) was demonstrated. The above method was validated for quantitative analysis. The validation confirmed its specificity, linearity, accuracy, precision (repeatability), and the flow rate, starting mobile phase organic content, column temperature, mobile phase composition, and gradient start time. The method was demonstrated to be robust, specific, linear, accurate, and precise (repeatable) over the range of 6%-120% of the target analyte range. A second quantitative SE-LC method was developed to separate six pharmaceutical drug product excipients by their classes--amino acids (methionine, arginine, and histidine) and antimicrobial preservatives (sodium benzoate, methylparaben, and propylparaben). This method employed a tandem column setup with a cation exchange column and reversed-phase column (C18) in tandem and utilized a pH gradient to elute the amino acids followed by an acetonitrile gradient to elute the antimicrobial preservatives within 18 minutes. The method was also validated and demonstrated to be specific, linear, accurate, and precise (repeatable) over the range of 50%-150% of the target analyte concentrations. Method robustness was also assessed using a full factorial design of experiments for which the factors investigated were mobile phase concentration, acetonitrile gradient start time and starting percentage of acetonitrile. Based on the factorial results for the experiments, with respect to the relative retention time of the critical pair (sodium benzoate: arginine), the mobile phase concentration and acetonitrile were significant factors that affected the separation. This method could be applied in pharmaceutical laboratories to measure amounts of methionine, arginine, histidine, sodium benzoate, methylparaben, and propylparaben in drug products.
- Open Access
- 20 July 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1731, 465178
Separation of weak acids, neutral compounds, and permanent anions using sequential elution liquid chromatography with tandem columns
- 20 July 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1731, 465178
Open AccessSeparation of weak acids, neutral compounds, and permanent anions using sequential elution liquid chromatography with tandem columns