Maggie Reed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maggie Reed has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
M. Platt
Texas A&M University
4 shared publications- Pratyush K. Patel
Northwestern University
4 shared publications - Roger K. Romani
Department of Physics, University of California Berkeley 4 , 366 LeConte Hall 7300, Berkeley, California 94720
4 shared publications - Rupak Mahapatra
Texas A & M Univ., College Station, TX (United States)
4 shared publications - Vetri Velan
Lawrence Berkeley National Laboratory
4 shared publications - Wei Guo
Florida State University
4 shared publications
Latest Publications
- 28 October 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (7)
Design studies of a pulsed quasimonoenergetic 2-keV neutron source for calibration of low threshold dark matter detectors
- 28 October 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (7)
Design studies of a pulsed quasimonoenergetic 2-keV neutron source for calibration of low threshold dark matter detectors
- 29 December 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (26)
Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events, and quasiparticle poisoning in superconducting sensors
Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE ν NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. In this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68±0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.
- 29 December 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (26)
Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events, and quasiparticle poisoning in superconducting sensors
Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE ν NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. In this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68±0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.
- 1 March 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (10)
Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter
We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.
- 1 March 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (10)
Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter
We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.
- 2 December 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (23)
A transition edge sensor operated in coincidence with a high sensitivity athermal phonon sensor for photon coupled rare event searches
Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a small photon sensor, in our case a transition edge sensor (TES) with a photon energy resolution σγ=368.4±0.4 meV, is colocated on the same substrate as a large high sensitivity athermal phonon sensor (APS) with a phonon energy resolution σphonon=701±2 meV. We show that single 3.061 eV photons absorbed in the photon-sensing TES deposit ∼35% of their energy in the electronic system of the TES, while ∼26% of the photon energy leaks out of the photon-sensing TES during the downconversion process and becomes absorbed by the APS. Backgrounds, which we associate with the broadly observed “low energy excess” (LEE), are observed to be largely coupled to either the TES (“singles” LEE), or phonon system, (“shared” LEE). At high energies, these backgrounds can be efficiently discriminated from TES photon absorption events, while at low energies, their misidentification as photon events is well modeled. With significant sensitivity improvements to both the TES and APS, this coincidence technique could be used to suppress backgrounds in bosonic dark matter searches down to energies near the superconducting bandgap of the sensor.
- 2 December 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (23)
A transition edge sensor operated in coincidence with a high sensitivity athermal phonon sensor for photon coupled rare event searches
Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a small photon sensor, in our case a transition edge sensor (TES) with a photon energy resolution σγ=368.4±0.4 meV, is colocated on the same substrate as a large high sensitivity athermal phonon sensor (APS) with a phonon energy resolution σphonon=701±2 meV. We show that single 3.061 eV photons absorbed in the photon-sensing TES deposit ∼35% of their energy in the electronic system of the TES, while ∼26% of the photon energy leaks out of the photon-sensing TES during the downconversion process and becomes absorbed by the APS. Backgrounds, which we associate with the broadly observed “low energy excess” (LEE), are observed to be largely coupled to either the TES (“singles” LEE), or phonon system, (“shared” LEE). At high energies, these backgrounds can be efficiently discriminated from TES photon absorption events, while at low energies, their misidentification as photon events is well modeled. With significant sensitivity improvements to both the TES and APS, this coincidence technique could be used to suppress backgrounds in bosonic dark matter searches down to energies near the superconducting bandgap of the sensor.
- Open Access
- 31 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-8
A stress-induced source of phonon bursts and quasiparticle poisoning
The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called “quasiparticle poisoning”. Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.
- 31 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-8
Open AccessA stress-induced source of phonon bursts and quasiparticle poisoning
The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called “quasiparticle poisoning”. Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.