VRVinícius D'ALmeida Rodrigues Ramos

Vinícius D'ALmeida Rodrigues Ramos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vinícius D'ALmeida Rodrigues Ramos has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Numerical analysis of the effects of corrosion on the punching shear capacity of reinforced concrete flat slabs with openings

    by Vinícius D'ALmeida Rodrigues Ramos, Leandro Mouta Trautwein, António Pinho Ramos, Elyson Andrew Pozo Liberati

    The reinforcement corrosion is one of the main degradation mechanisms in reinforced concrete structures. Its effects can harm structural elements by reducing mechanical capacity, mainly due to diminished reinforcement properties and expansive reactions within the concrete. In addition, the effects of punching shear on flat slabs can be detrimental, as failure of the slab‐column connection can trigger a progressive collapse of the entire structure. This study focused on investigating three reinforced concrete flat slabs, based on experimental results concerning punching shear capacity when subject to reinforcement corrosion. The slabs, without shear reinforcement and including openings adjacent to the slab‐column connection, were subjected to a corrosion degree of 20%. Finite element models were developed using ABAQUS software. Modeling methods were applied to analyze the effects of corrosion on the geometric and mechanical properties of reinforcement, concrete, and steel‐concrete adhesion. The results showed that, as corrosion increased, the ultimate load of the slabs decreased. Specifically, there was an average reduction of 23.4% for 20% corrosion. The stiffness and ductility of the slabs were affected, especially those with openings adjacent to the column. Following load–displacement analyses of the slabs, the punching load capacity results were compared to the estimates from Eurocode 2, NBR 6118, ACI 318, fib Model Code, and FprEN 1992 1‐1 codes. The normative codes underestimated the strength capacity of corroded slabs, proving conservative, with Eurocode 2, NBR 6118, and FprEN 1992 1‐1 providing the most precise and least dispersed results.

  • Numerical analysis of the corrosion impact on the punching shear capacity of flat slabs with openings

    by Vinícius D' Almeida R. Ramos, Elyson A. P. Liberati, Leandro M. Trautwein

    The effects generated by punching shear failure in flat slabs are catastrophic, as the failure of the slab‐column joint can cause a progressive collapse of the building. Furthermore, when exposed to aggressive environments, reinforced concrete structures can be degraded due to the penalization of the mechanical and geometric properties of the reinforcement and concrete. Therefore, this study intends to investigate the behavior of corroded reinforced concrete flat slabs with adjacent openings to the column. Three nonlinear finite element models of flat slabs based on experimental results were constructed and validated in the ABAQUS software and subsequently subjected to a parametric analysis to investigate the effects of different corrosion degrees on their punching shear capacity. The results demonstrated that corrosion of the reinforcement significantly affected the load capacity of the numerical models, reducing the ultimate load by up to 30%. Furthermore, the increase in corrosion caused an intensification of the cracking of the slabs, indicating that the cracking patterns increased as the degree of corrosion increased. The results obtained by experimental tests and numerical simulations were compared with predictions by the codes Eurocode, fib Model Code, American Concrete Institute 318, FprEN 1992 1‐1, and The Brazilian Association of Technical Standards Brazilian Regulatory Standard 6118. The results showed that most codes generate very conservative results.


  • Open Access

    CALIBRAÇÃO DOS PARÂMETROS DE PLASTICIDADE DANIFICADA DO CONCRETO PARA LAJES LISAS NO ABAQUS

    by Vinícius D´aLmeida Rodrigues Ramos, Elyson Andrew Pozo Liberati, Leandro Mouta Trautwein

    Nesse trabalho foram realizadas análises não lineares em elementos finitos para investigar o comportamento de lajes lisas submetidas à punção. As análises foram conduzidas por meio da calibração dos parâmetros de plasticidade do modelo Concrete Damaged Plasticity (CDP), presente no software ABAQUS, e então comparadas aos resultados experimentais ligações laje-pilar com aberturas circulares adjacentes ao pilar interno. A calibração indicou a dependência dos modelos quanto à alguns parâmetros, e ainda, que os modelos propostos podem prever adequadamente a capacidade resistente à punção das lajes.