Xin Zhong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Xin Zhong has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Agnibh Dasgupta
Department of Computer Science University of Nebraska Omaha Omaha NE USA
1 shared publication - Bruno Reynard
Laboratoire de Géologie de Lyon, Univ Lyon, ENS de Lyon, Univ Lyon1, CNRS, France
1 shared publication - Chao Li
School of Material Science and Engineering, University of Jinan, Jinan, 250022, P. R. China
1 shared publication - Frank Y. Shih
Department of Computer Science, New Jersey Institute of Technology, Newark, NJ 07102, USA
1 shared publication - Geng Wang
Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China
1 shared publication Jing Zhang
Joint Shantou International Eye Center of Shantou University and the Chinese University of Hong Kong, Shantou, Guangdong, China
1 shared publication
Latest Publications
- 7 October 2025
- Published by BMJ in British Journal of Ophthalmology
- Vol. 110 (3) , 268-274
Comparative efficacy of fundus photography, optical coherence tomography and multifocal electroretinography in predicting postoperative visual acuity in highly myopic cataract patients
Aims To compare the predictive efficacy of precataract extraction fundus photography, optical coherence tomography (OCT) and multifocal electroretinogram (mfERG) in determining 3-month postcataract extraction best-corrected visual acuity (BCVA) in patients with high myopia complicated by cataracts. Methods This retrospective cohort study included 58 highly myopic eyes that underwent cataract surgery. Preoperative assessments included macular lesion grading from fundus photography based on the META-pathologic myopia classification; assessment of outer retinal structural integrity, specifically ellipsoid zone (EZ) status, via OCT and mfERG parameters, including P1 response density and implicit time from five concentric rings. Postoperative BCVA was recorded at 3 months. Statistical analyses included Pearson correlation, multiple linear regression and receiver operating characteristic curve analysis to evaluate the relationship and predictive power of each modality and a combined model. Results The study included 58 eyes with a mean age of 62.7±10.0 years. Preoperative BCVA, myopic maculopathy grading, EZ status and central mfERG parameters all showed strong correlations with postoperative BCVA (all pConclusion Preoperative assessments of fundus morphology, OCT-derived microstructures and retinal function are all valuable, independent predictors of visual outcomes after cataract surgery in highly myopic eyes.
- 7 October 2025
- Published by BMJ in British Journal of Ophthalmology
- Vol. 110 (3) , 268-274
Comparative efficacy of fundus photography, optical coherence tomography and multifocal electroretinography in predicting postoperative visual acuity in highly myopic cataract patients
Aims To compare the predictive efficacy of precataract extraction fundus photography, optical coherence tomography (OCT) and multifocal electroretinogram (mfERG) in determining 3-month postcataract extraction best-corrected visual acuity (BCVA) in patients with high myopia complicated by cataracts. Methods This retrospective cohort study included 58 highly myopic eyes that underwent cataract surgery. Preoperative assessments included macular lesion grading from fundus photography based on the META-pathologic myopia classification; assessment of outer retinal structural integrity, specifically ellipsoid zone (EZ) status, via OCT and mfERG parameters, including P1 response density and implicit time from five concentric rings. Postoperative BCVA was recorded at 3 months. Statistical analyses included Pearson correlation, multiple linear regression and receiver operating characteristic curve analysis to evaluate the relationship and predictive power of each modality and a combined model. Results The study included 58 eyes with a mean age of 62.7±10.0 years. Preoperative BCVA, myopic maculopathy grading, EZ status and central mfERG parameters all showed strong correlations with postoperative BCVA (all pConclusion Preoperative assessments of fundus morphology, OCT-derived microstructures and retinal function are all valuable, independent predictors of visual outcomes after cataract surgery in highly myopic eyes.
- 6 February 2024
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 12 (2) , 112155
Bio-oil as a filler for enhancing development of micropores in activation of chicken bone
- 6 February 2024
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 12 (2) , 112155
Bio-oil as a filler for enhancing development of micropores in activation of chicken bone
- Open Access
- 1 January 2024
- Published by Wiley in Journal of Ophthalmology
- Vol. 2024 (1) , 4256371
Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery
Background. This study aims to investigate the agreement between the NK and KS formulas in predicting the vault after implantation of an EVO‐implantable collamer lens (ICL). Methods. This retrospective study included 106 eyes of 57 patients who underwent ICL‐V4c implantation. Preoperative vault prediction was conducted by utilizing the NK and KS formulas, with postoperative measurements by anterior segment optical coherence tomography (AS‐OCT) at one month. The analysis focused on the consistency between predicted and achieved vaults, as well as the correlation between the achieved vault and various biometric parameters. Results. The mean achieved vault was 605.25 ± 212.72 µm, which was significantly smaller than the predicted vaults of 710.08 ± 195.08 and 673.80 ± 212.76 µm, using the NK and KS formulas, respectively (P < 0.05). The mean differences between the achieved vault and the predicted vault using the NK formula and KS formula were −104.82 μm (95% LoA: −600.38–391.19 μm) and −68.55 μm (95% LoA: −628.91–491.82 μm), respectively. Anterior chamber depth (ACD), vertical sulcus‐to‐sulcus (V‐STS) diameter, and crystalline lens rise (CLR) were independent factors associated with the achieved vault (P < 0.05). The two formulas showed no statistically significant difference in absolute prediction error (APE). Conclusion. The NK formula exhibited superior consistency and low predictive error compared to the KS formula in the 12.6 mm ICL group. AS‐OCT measurements overestimated the predicted ICL vault, especially in the 13.2 mm ICL size selection. Relying solely on the NK or KS formulas for predicting vaults before ICL surgery is not recommended.
- 1 January 2024
- Published by Wiley in Journal of Ophthalmology
- Vol. 2024 (1) , 4256371
Open AccessComparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery
Background. This study aims to investigate the agreement between the NK and KS formulas in predicting the vault after implantation of an EVO‐implantable collamer lens (ICL). Methods. This retrospective study included 106 eyes of 57 patients who underwent ICL‐V4c implantation. Preoperative vault prediction was conducted by utilizing the NK and KS formulas, with postoperative measurements by anterior segment optical coherence tomography (AS‐OCT) at one month. The analysis focused on the consistency between predicted and achieved vaults, as well as the correlation between the achieved vault and various biometric parameters. Results. The mean achieved vault was 605.25 ± 212.72 µm, which was significantly smaller than the predicted vaults of 710.08 ± 195.08 and 673.80 ± 212.76 µm, using the NK and KS formulas, respectively (P < 0.05). The mean differences between the achieved vault and the predicted vault using the NK formula and KS formula were −104.82 μm (95% LoA: −600.38–391.19 μm) and −68.55 μm (95% LoA: −628.91–491.82 μm), respectively. Anterior chamber depth (ACD), vertical sulcus‐to‐sulcus (V‐STS) diameter, and crystalline lens rise (CLR) were independent factors associated with the achieved vault (P < 0.05). The two formulas showed no statistically significant difference in absolute prediction error (APE). Conclusion. The NK formula exhibited superior consistency and low predictive error compared to the KS formula in the 12.6 mm ICL group. AS‐OCT measurements overestimated the predicted ICL vault, especially in the 13.2 mm ICL size selection. Relying solely on the NK or KS formulas for predicting vaults before ICL surgery is not recommended.
- Open Access
- 8 February 2023
- Published by Copernicus GmbH
Supplementary material to "Quartz under stress: Raman calibration and applications to geobarometry of metamorphic inclusions"
- 8 February 2023
- Published by Copernicus GmbH
Open AccessSupplementary material to "Quartz under stress: Raman calibration and applications to geobarometry of metamorphic inclusions"
- Open Access
Perspective Transformation Layer
Incorporating geometric transformations that reflect the relative position changes between an observer and an object into computer vision and deep learning models has attracted much attention in recent years. However, the existing proposals mainly focus on the affine transformation that is insufficient to reflect such geometric position changes. Furthermore, current solutions often apply a neural network module to learn a single transformation matrix, which not only ignores the importance of multi-view analysis but also includes extra training parameters from the module apart from the transformation matrix parameters that increase the model complexity. In this paper, a perspective transformation layer is proposed in the context of deep learning. The proposed layer can learn homography, therefore reflecting the geometric positions between observers and objects. In addition, by directly training its transformation matrices, a single proposed layer can learn an adjustable number of multiple viewpoints without considering module parameters. The experiments and evaluations confirm the superiority of the proposed layer.
Open AccessPerspective Transformation Layer
Incorporating geometric transformations that reflect the relative position changes between an observer and an object into computer vision and deep learning models has attracted much attention in recent years. However, the existing proposals mainly focus on the affine transformation that is insufficient to reflect such geometric position changes. Furthermore, current solutions often apply a neural network module to learn a single transformation matrix, which not only ignores the importance of multi-view analysis but also includes extra training parameters from the module apart from the transformation matrix parameters that increase the model complexity. In this paper, a perspective transformation layer is proposed in the context of deep learning. The proposed layer can learn homography, therefore reflecting the geometric positions between observers and objects. In addition, by directly training its transformation matrices, a single proposed layer can learn an adjustable number of multiple viewpoints without considering module parameters. The experiments and evaluations confirm the superiority of the proposed layer.