XZXin Zhong

Xin Zhong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xin Zhong has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparative efficacy of fundus photography, optical coherence tomography and multifocal electroretinography in predicting postoperative visual acuity in highly myopic cataract patients

    by Tingkun Shi, Jing Zhang, Limei Weng, Xin Zhong, Yuqiang Huang

    Aims To compare the predictive efficacy of precataract extraction fundus photography, optical coherence tomography (OCT) and multifocal electroretinogram (mfERG) in determining 3-month postcataract extraction best-corrected visual acuity (BCVA) in patients with high myopia complicated by cataracts. Methods This retrospective cohort study included 58 highly myopic eyes that underwent cataract surgery. Preoperative assessments included macular lesion grading from fundus photography based on the META-pathologic myopia classification; assessment of outer retinal structural integrity, specifically ellipsoid zone (EZ) status, via OCT and mfERG parameters, including P1 response density and implicit time from five concentric rings. Postoperative BCVA was recorded at 3 months. Statistical analyses included Pearson correlation, multiple linear regression and receiver operating characteristic curve analysis to evaluate the relationship and predictive power of each modality and a combined model. Results The study included 58 eyes with a mean age of 62.7±10.0 years. Preoperative BCVA, myopic maculopathy grading, EZ status and central mfERG parameters all showed strong correlations with postoperative BCVA (all pConclusion Preoperative assessments of fundus morphology, OCT-derived microstructures and retinal function are all valuable, independent predictors of visual outcomes after cataract surgery in highly myopic eyes.


  • Bio-oil as a filler for enhancing development of micropores in activation of chicken bone

    by Xin Zhong, Chao Li, Lijun Zhang, Shu Zhang, Yi Wang, Song Hu, Jun Xiang, Xun Hu


  • Open Access

    Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery

    by Xin Zhong, Yan Li, Yuancun Li, Geng Wang, Yali Du, Mingzhi Zhang

    Background. This study aims to investigate the agreement between the NK and KS formulas in predicting the vault after implantation of an EVO‐implantable collamer lens (ICL). Methods. This retrospective study included 106 eyes of 57 patients who underwent ICL‐V4c implantation. Preoperative vault prediction was conducted by utilizing the NK and KS formulas, with postoperative measurements by anterior segment optical coherence tomography (AS‐OCT) at one month. The analysis focused on the consistency between predicted and achieved vaults, as well as the correlation between the achieved vault and various biometric parameters. Results. The mean achieved vault was 605.25 ± 212.72 µm, which was significantly smaller than the predicted vaults of 710.08 ± 195.08 and 673.80 ± 212.76 µm, using the NK and KS formulas, respectively (P < 0.05). The mean differences between the achieved vault and the predicted vault using the NK formula and KS formula were −104.82 μm (95% LoA: −600.38–391.19 μm) and −68.55 μm (95% LoA: −628.91–491.82 μm), respectively. Anterior chamber depth (ACD), vertical sulcus‐to‐sulcus (V‐STS) diameter, and crystalline lens rise (CLR) were independent factors associated with the achieved vault (P < 0.05). The two formulas showed no statistically significant difference in absolute prediction error (APE). Conclusion. The NK formula exhibited superior consistency and low predictive error compared to the KS formula in the 12.6 mm ICL group. AS‐OCT measurements overestimated the predicted ICL vault, especially in the 13.2 mm ICL size selection. Relying solely on the NK or KS formulas for predicting vaults before ICL surgery is not recommended.


  • Open Access

    Perspective Transformation Layer

    by Nishan Khatri, Agnibh Dasgupta, Yucong Shen, Xin Zhong, Frank Y. Shih

    Incorporating geometric transformations that reflect the relative position changes between an observer and an object into computer vision and deep learning models has attracted much attention in recent years. However, the existing proposals mainly focus on the affine transformation that is insufficient to reflect such geometric position changes. Furthermore, current solutions often apply a neural network module to learn a single transformation matrix, which not only ignores the importance of multi-view analysis but also includes extra training parameters from the module apart from the transformation matrix parameters that increase the model complexity. In this paper, a perspective transformation layer is proposed in the context of deep learning. The proposed layer can learn homography, therefore reflecting the geometric positions between observers and objects. In addition, by directly training its transformation matrices, a single proposed layer can learn an adjustable number of multiple viewpoints without considering module parameters. The experiments and evaluations confirm the superiority of the proposed layer.