Muhammad Iqbal Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muhammad Iqbal Khan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bruno da Silva
Department of Electronics and Informatics, Vrije Universiteit Brussel, 1050 Brussels, Belgium
3 shared publications - Abdessamad Nassihi
Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium
1 shared publication - Ahmed Sadaqa
Department of Electronic and Information, Vrije Universiteit Brussel, Brussels, Belgium
1 shared publication - Johan Stiens
Department of Electronics and Informatics, Vrije Universiteit Brussel, Brussels, Belgium
1 shared publication - Nicolas Roberto Becerra Machado
Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium
1 shared publication - Workineh Tesema
Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussel, Belgium
1 shared publication
Latest Publications
- Open Access
- 10 March 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (6) , 2648
Exploiting Low-Power Techniques of a Flash-Based SoC FPGA for Energy-Efficient Edge Processing
Battery-powered edge systems must operate under tight energy budgets while facing growing computational demand from rapidly evolving edge workloads. Field-programmable gate arrays (FPGAs) offer middle ground when optimized for energy, especially flash-based FPGAs due to inherent low-power characteristics. Microchip flash-based SoC FPGAs further expose ultra-low-power (LP) modes including fabric Flash*Freeze (F*F), processor sleep and selectable standby clocks. Combining these modes with HW/SW partitioning and clock-frequency scaling can reduce energy for low-duty-cycle workloads; however, selecting an energy-efficient operating point in this multidimensional design space is non-trivial. This work explores the design space by measuring and analyzing LP modes across three architectural approaches (SW, co-design, and HW) under frequency scaling on a Microchip Smartfusion2 platform, using a low-duty-cycle heart-rate monitoring workload. Measurements indicate that, for low-duty-cycle workloads, total energy is dominated by the idle phase and is minimized by combining fabric-F*F with processor sleep. The results further show that main-clock downscaling reduces active-phase current but has limited impact on idle consumption once F*F and sleep are applied, while standby-clock selection trades idle current against LP entry/exit latency. Event-rate scaling further shows that the energy-optimal operating point can shift with duty cycle. We provide measurement-based guidelines for duty-cycle-aware energy-efficient operating point selection in similar flash-based SoC platforms.
- 10 March 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (6) , 2648
Open AccessExploiting Low-Power Techniques of a Flash-Based SoC FPGA for Energy-Efficient Edge Processing
Battery-powered edge systems must operate under tight energy budgets while facing growing computational demand from rapidly evolving edge workloads. Field-programmable gate arrays (FPGAs) offer middle ground when optimized for energy, especially flash-based FPGAs due to inherent low-power characteristics. Microchip flash-based SoC FPGAs further expose ultra-low-power (LP) modes including fabric Flash*Freeze (F*F), processor sleep and selectable standby clocks. Combining these modes with HW/SW partitioning and clock-frequency scaling can reduce energy for low-duty-cycle workloads; however, selecting an energy-efficient operating point in this multidimensional design space is non-trivial. This work explores the design space by measuring and analyzing LP modes across three architectural approaches (SW, co-design, and HW) under frequency scaling on a Microchip Smartfusion2 platform, using a low-duty-cycle heart-rate monitoring workload. Measurements indicate that, for low-duty-cycle workloads, total energy is dominated by the idle phase and is minimized by combining fabric-F*F with processor sleep. The results further show that main-clock downscaling reduces active-phase current but has limited impact on idle consumption once F*F and sleep are applied, while standby-clock selection trades idle current against LP entry/exit latency. Event-rate scaling further shows that the energy-optimal operating point can shift with duty cycle. We provide measurement-based guidelines for duty-cycle-aware energy-efficient operating point selection in similar flash-based SoC platforms.
- Open Access
- 17 October 2024
- Published by MDPI AG in Electronics
- Vol. 13 (20) , 4094
Harnessing FPGA Technology for Energy-Efficient Wearable Medical Devices
Over the past decade, wearable medical devices (WMDs) have become the norm for continuous health monitoring, enabling real-time vital sign analysis and preventive healthcare. These battery-powered devices face computational power, size, and energy resource constraints. Traditionally, low-power microcontrollers (MCUs) and application-specific integrated circuits (ASICs) have been used for their energy efficiency. However, the increasing demand for multi-modal sensors and artificial intelligence (AI) requires more computational power than MCUs, and rapidly evolving AI asks for more flexibility, which ASICs lack. Field-programmable gate arrays (FPGAs), which are more efficient than MCUs and more flexible than ASICs, offer a potential solution when optimized for energy consumption. By combining real-time reconfigurability with intelligent energy optimization strategies, FPGAs can provide energy-efficient solutions for handling multimodal sensors and evolving AI requirements. This paper reviews low-power strategies toward FPGA-based WMD for physiological monitoring. It examines low-power FPGA families, highlighting their potential in power-sensitive applications. Future research directions are suggested, including exploring underutilized optimizations like sleep mode, voltage scaling, partial reconfiguration, and compressed learning and investigating underexplored flash and hybrid-based FPGAs. Overall, it provides guidelines for designing energy-efficient FPGA-based WMDs.
- 17 October 2024
- Published by MDPI AG in Electronics
- Vol. 13 (20) , 4094
Open AccessHarnessing FPGA Technology for Energy-Efficient Wearable Medical Devices
Over the past decade, wearable medical devices (WMDs) have become the norm for continuous health monitoring, enabling real-time vital sign analysis and preventive healthcare. These battery-powered devices face computational power, size, and energy resource constraints. Traditionally, low-power microcontrollers (MCUs) and application-specific integrated circuits (ASICs) have been used for their energy efficiency. However, the increasing demand for multi-modal sensors and artificial intelligence (AI) requires more computational power than MCUs, and rapidly evolving AI asks for more flexibility, which ASICs lack. Field-programmable gate arrays (FPGAs), which are more efficient than MCUs and more flexible than ASICs, offer a potential solution when optimized for energy consumption. By combining real-time reconfigurability with intelligent energy optimization strategies, FPGAs can provide energy-efficient solutions for handling multimodal sensors and evolving AI requirements. This paper reviews low-power strategies toward FPGA-based WMD for physiological monitoring. It examines low-power FPGA families, highlighting their potential in power-sensitive applications. Future research directions are suggested, including exploring underutilized optimizations like sleep mode, voltage scaling, partial reconfiguration, and compressed learning and investigating underexplored flash and hybrid-based FPGAs. Overall, it provides guidelines for designing energy-efficient FPGA-based WMDs.
- Open Access
- 5 August 2024
- Published by MDPI AG in Electronics
- Vol. 13 (15) , 3097
A Taxonomy of Low-Power Techniques in Wearable Medical Devices for Healthcare Applications
Chronic diseases are the most prevalent and non-communicable health crisis globally. Most chronic disease patients require continuous physiological monitoring, using wearable technology for timely treatment, precise illness detection, and preventive healthcare. Nonetheless, efficient power management is required for such resource-constrained wearable devices. This work aims to analyze low-power techniques (LPTs) in wearable medical devices using a data-driven approach and identify novel approaches promising higher power savings. Through an intensive literature analysis, we identify the most relevant LPTs for minimizing power consumption in wearable devices for physiological monitoring while recognizing the barriers to adopting these techniques. As a result, a novel taxonomy based on the common characteristics of the LPTs is proposed, along with strategies for the combination of LPTs. Through our analysis, we propose possible enhancements in using LPTs and suggest mechanisms for the medical device industry to facilitate their adoption. Overall, our proposed strategies guide the use of LPTs on wearable medical devices toward continuous physiological monitoring.
- 5 August 2024
- Published by MDPI AG in Electronics
- Vol. 13 (15) , 3097
Open AccessA Taxonomy of Low-Power Techniques in Wearable Medical Devices for Healthcare Applications
Chronic diseases are the most prevalent and non-communicable health crisis globally. Most chronic disease patients require continuous physiological monitoring, using wearable technology for timely treatment, precise illness detection, and preventive healthcare. Nonetheless, efficient power management is required for such resource-constrained wearable devices. This work aims to analyze low-power techniques (LPTs) in wearable medical devices using a data-driven approach and identify novel approaches promising higher power savings. Through an intensive literature analysis, we identify the most relevant LPTs for minimizing power consumption in wearable devices for physiological monitoring while recognizing the barriers to adopting these techniques. As a result, a novel taxonomy based on the common characteristics of the LPTs is proposed, along with strategies for the combination of LPTs. Through our analysis, we propose possible enhancements in using LPTs and suggest mechanisms for the medical device industry to facilitate their adoption. Overall, our proposed strategies guide the use of LPTs on wearable medical devices toward continuous physiological monitoring.