Hanlei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hanlei Wang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Kai Wu
University of South Florida
6 shared publications - Rui He
Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA
6 shared publications - Ebrahim Azizi
Texas Tech University, Lubbock, TX 79409, United States, Lubbock, Texas, 79409, United States
5 shared publications - Hansong Zuo
Lubbock High School, 2004 19th St, Lubbock, Texas, 79401-4606, United States
4 shared publications - Vinit Kumar Chugh
Department of Electrical and Computer Engineering, University of Minnesota, 200 Union St. SE Kenneth H. Keller Hall, Room 3-147D, University of Minnesota, Minneapolis, Minnesota, 55455, UNITED STATES
4 shared publications - Niranjan A. Natekar
Western Digital Corporation, San Jose, San Jose, California, 95119-1003, UNITED STATES
2 shared publications
Latest Publications
- 9 October 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (42) , 19570-19606
Magnetic Nanoparticle Transducers for Magnetogenetics: Materials Design, Biointerfaces, and Transduction Mechanisms
Over the years, magnetic nanoparticles (MNPs) have evolved from passive imaging and delivery agents into active transducers that convert externally applied magnetic fields into localized biological stimuli. This transition has created opportunities for magnetogenetics, in which MNPs serve as remotely controlled biointerfaces for regulating cellular activity, tissue function, and therapeutic responses. In this review, we discuss MNP transducers for magnetogenetics from the perspective of materials design, biointerface engineering, and transduction mechanisms. We start with magnetothermal transduction, where nanoparticles dissipate heat under alternating magnetic fields (AMFs) to activate thermosensitive ion channels such as TRPV1, enabling wireless neuronal activation, deep brain stimulation (DBS), regenerative signaling, and disease therapy. We then discuss magnetomechanical transduction, where nanoparticles, nano/micro-discs, nanochains, etc., generate forces, torques, oscillations, or matrix deformation to activate mechanosensitive channels, integrin-mediated pathways, stem cell differentiation, immune modulation, and tumor inhibition. Next, we examine magnetoelectric transduction, where magnetostrictive-piezoelectric materials convert magnetic inputs into local electric fields or surface potentials for neural stimulation, DBS, nerve regeneration, and wound healing. Across these modalities, biological outcomes are governed by intrinsic magnetic properties and several other factors, including particle geometry, anisotropy, surface chemistry, protein corona formation, tissue retention, field waveform, and proximity to the biological target. We further comment on key design principles, including mechanism-specific dosimetry, geometry-field co-design, biointerface localization, targeting specificity, clearance, and chronic safety. Finally, we highlight opportunities for purpose-built, programmable, and closed-loop magnetic biointerfaces that integrate material architecture, magnetic-field input, and biological target selection for precise control of cellular and tissue function.
- 9 October 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (42) , 19570-19606
Magnetic Nanoparticle Transducers for Magnetogenetics: Materials Design, Biointerfaces, and Transduction Mechanisms
Over the years, magnetic nanoparticles (MNPs) have evolved from passive imaging and delivery agents into active transducers that convert externally applied magnetic fields into localized biological stimuli. This transition has created opportunities for magnetogenetics, in which MNPs serve as remotely controlled biointerfaces for regulating cellular activity, tissue function, and therapeutic responses. In this review, we discuss MNP transducers for magnetogenetics from the perspective of materials design, biointerface engineering, and transduction mechanisms. We start with magnetothermal transduction, where nanoparticles dissipate heat under alternating magnetic fields (AMFs) to activate thermosensitive ion channels such as TRPV1, enabling wireless neuronal activation, deep brain stimulation (DBS), regenerative signaling, and disease therapy. We then discuss magnetomechanical transduction, where nanoparticles, nano/micro-discs, nanochains, etc., generate forces, torques, oscillations, or matrix deformation to activate mechanosensitive channels, integrin-mediated pathways, stem cell differentiation, immune modulation, and tumor inhibition. Next, we examine magnetoelectric transduction, where magnetostrictive-piezoelectric materials convert magnetic inputs into local electric fields or surface potentials for neural stimulation, DBS, nerve regeneration, and wound healing. Across these modalities, biological outcomes are governed by intrinsic magnetic properties and several other factors, including particle geometry, anisotropy, surface chemistry, protein corona formation, tissue retention, field waveform, and proximity to the biological target. We further comment on key design principles, including mechanism-specific dosimetry, geometry-field co-design, biointerface localization, targeting specificity, clearance, and chronic safety. Finally, we highlight opportunities for purpose-built, programmable, and closed-loop magnetic biointerfaces that integrate material architecture, magnetic-field input, and biological target selection for precise control of cellular and tissue function.
- Open Access
- 28 August 2026
- Published by IOP Publishing in Nano Futures
- Vol. 10 (3) , 032503
Perspective: magnetic tunnel junctions for in-sensor computing
Large-area sensing systems, such as biomedical imaging, nondestructive evaluation, current mapping, soft robotics, and distributed internet-of-things monitoring, generate massive spatial and temporal data streams that are costly to digitize, transfer, and process using conventional sensor-processor architectures. In-sensor computing offers a promising route to overcome this bottleneck by moving early-stage computation directly to the sensing front end, thereby reducing data movement, latency, and power consumption. Magnetic tunnel junctions (MTJs) are uniquely positioned for this emerging paradigm because they combine magnetic field sensitivity, nonvolatile resistance states, CMOS compatibility, fast spintronic dynamics, stochastic switching, and low-standby-power operation. These properties allow MTJs to function not only as magnetic sensors or memory cells, but also as stateful computing elements. This perspective discusses recent progress in MTJ-based computing and outlines how these advances can guide the development of next-generation MTJ-based in-sensor computing. We first review the working principles of MTJs and their use in basic logic functions, including reconfigurable Boolean logic, logic-in-memory, and reliability considerations. We then discuss MTJ implementations of neural network primitives, including feedforward neural networks, convolutional neural networks, recurrent neural networks, and spiking neural networks, highlighting how nonlinear magnetization dynamics, oscillatory behavior, and probabilistic switching can support neuromorphic computation. Finally, we examine emerging magnetic near-sensor, multifunctional MTJ, and VC-MTJ processing-in-pixel concepts and identify key challenges for future MTJ sensor-computing arrays. We argue that the next major opportunity is to engineer large-area MTJ sensor arrays that perform local thresholding, event detection, feature extraction, and compressed readout directly at the magnetic sensing interface.
- 28 August 2026
- Published by IOP Publishing in Nano Futures
- Vol. 10 (3) , 032503
Open AccessPerspective: magnetic tunnel junctions for in-sensor computing
Large-area sensing systems, such as biomedical imaging, nondestructive evaluation, current mapping, soft robotics, and distributed internet-of-things monitoring, generate massive spatial and temporal data streams that are costly to digitize, transfer, and process using conventional sensor-processor architectures. In-sensor computing offers a promising route to overcome this bottleneck by moving early-stage computation directly to the sensing front end, thereby reducing data movement, latency, and power consumption. Magnetic tunnel junctions (MTJs) are uniquely positioned for this emerging paradigm because they combine magnetic field sensitivity, nonvolatile resistance states, CMOS compatibility, fast spintronic dynamics, stochastic switching, and low-standby-power operation. These properties allow MTJs to function not only as magnetic sensors or memory cells, but also as stateful computing elements. This perspective discusses recent progress in MTJ-based computing and outlines how these advances can guide the development of next-generation MTJ-based in-sensor computing. We first review the working principles of MTJs and their use in basic logic functions, including reconfigurable Boolean logic, logic-in-memory, and reliability considerations. We then discuss MTJ implementations of neural network primitives, including feedforward neural networks, convolutional neural networks, recurrent neural networks, and spiking neural networks, highlighting how nonlinear magnetization dynamics, oscillatory behavior, and probabilistic switching can support neuromorphic computation. Finally, we examine emerging magnetic near-sensor, multifunctional MTJ, and VC-MTJ processing-in-pixel concepts and identify key challenges for future MTJ sensor-computing arrays. We argue that the next major opportunity is to engineer large-area MTJ sensor arrays that perform local thresholding, event detection, feature extraction, and compressed readout directly at the magnetic sensing interface.
- 27 August 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (8) , 084427
Dual-functional magnetic nanoparticles: A stochastic Langevin study of imaging-heating trade-offs
Magnetic nanoparticles (MNPs) are central to magnetic particle imaging (MPI) and magnetic hyperthermia. The intrinsic properties of MNPs critically determine the performance of each modality individually. The integration of imaging and therapy within a single MPI-hyperthermia platform is especially attractive, as it enables mapping of MNP tracer distribution using MPI prior to thermal treatment, thereby guiding the subsequent delivery of localized hyperthermia. In such dual-functional systems, however, nanoparticle properties play a more complex and potentially different role than in standalone applications. Understanding how these intrinsic characteristics govern the sequential imaging and heating performance within a unified platform is therefore essential for the rational design of effective theranostic systems. Nevertheless, the impact of the nanoparticles' inherent characteristics on achieving optimal imaging and heating performance across both imaging and therapeutic stages has not yet been thoroughly investigated. In this work, we present a comprehensive modeling-based framework to optimize dual-functional MPI-hyperthermia performance by systematically investigating three MNP core sizes (20, 25, and 30 nm) over broad ranges of anisotropy constants and saturation magnetizations using a stochastic Langevin model. Magnetization dynamics are evaluated at 25 kHz (for MPI use) and 350 kHz (for hyperthermia use) alternating magnetic fields. Performance is quantified using the full width at half-maximum and signal-to-noise ratio to assess MPI spatial resolution and signal quality, respectively, and the specific absorption rate to evaluate hyperthermia efficiency. The competing behavior of these performance metrics is first analyzed through direct visualization of the simulated data, revealing clear trade-offs between spatial resolution, signal quality, and heating efficiency. To capture the underlying nonlinear relationships more rigorously, Gaussian process surrogate models are constructed for each metric and validated for predictive accuracy. Building on these models, a multiobjective optimization framework is employed to identify optimal combinations of anisotropy constant and saturation magnetization for each core size that balance MPI and hyperthermia performance. The results demonstrate a strong dependence of the optimal parameter regions on MNP core size, with distinct trade-offs emerging between imaging and therapeutic objectives. This study provides a systematic and extensible framework for the rational design of dual-functional MNPs and offers quantitative guidance for optimizing particle properties in combined MPI-guided magnetic hyperthermia applications.
- 27 August 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (8) , 084427
Dual-functional magnetic nanoparticles: A stochastic Langevin study of imaging-heating trade-offs
Magnetic nanoparticles (MNPs) are central to magnetic particle imaging (MPI) and magnetic hyperthermia. The intrinsic properties of MNPs critically determine the performance of each modality individually. The integration of imaging and therapy within a single MPI-hyperthermia platform is especially attractive, as it enables mapping of MNP tracer distribution using MPI prior to thermal treatment, thereby guiding the subsequent delivery of localized hyperthermia. In such dual-functional systems, however, nanoparticle properties play a more complex and potentially different role than in standalone applications. Understanding how these intrinsic characteristics govern the sequential imaging and heating performance within a unified platform is therefore essential for the rational design of effective theranostic systems. Nevertheless, the impact of the nanoparticles' inherent characteristics on achieving optimal imaging and heating performance across both imaging and therapeutic stages has not yet been thoroughly investigated. In this work, we present a comprehensive modeling-based framework to optimize dual-functional MPI-hyperthermia performance by systematically investigating three MNP core sizes (20, 25, and 30 nm) over broad ranges of anisotropy constants and saturation magnetizations using a stochastic Langevin model. Magnetization dynamics are evaluated at 25 kHz (for MPI use) and 350 kHz (for hyperthermia use) alternating magnetic fields. Performance is quantified using the full width at half-maximum and signal-to-noise ratio to assess MPI spatial resolution and signal quality, respectively, and the specific absorption rate to evaluate hyperthermia efficiency. The competing behavior of these performance metrics is first analyzed through direct visualization of the simulated data, revealing clear trade-offs between spatial resolution, signal quality, and heating efficiency. To capture the underlying nonlinear relationships more rigorously, Gaussian process surrogate models are constructed for each metric and validated for predictive accuracy. Building on these models, a multiobjective optimization framework is employed to identify optimal combinations of anisotropy constant and saturation magnetization for each core size that balance MPI and hyperthermia performance. The results demonstrate a strong dependence of the optimal parameter regions on MNP core size, with distinct trade-offs emerging between imaging and therapeutic objectives. This study provides a systematic and extensible framework for the rational design of dual-functional MNPs and offers quantitative guidance for optimizing particle properties in combined MPI-guided magnetic hyperthermia applications.
- Open Access
- 22 May 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (20) , 205001
A systematic framework for harmonic set selection in multiplexed magnetic particle spectroscopy
Magnetic particle spectroscopy (MPS) has emerged as a powerful biosensing modality due to its high sensitivity, matrix-free detection, and compatibility with point-of-care diagnostics. However, the lack of robust multiplexing capability remains a major bottleneck that limits its broader application in complex bioassays. To address this challenge, spatial and spectral separation strategies have been explored in recent years. While spatial separation approaches enable multiplexing without sacrificing sensitivity, they require physically distinct assay regions and substantially increase assay complexity, cost, and reagent consumption. In contrast, spectral separation offers a more resource-efficient solution by decoding multiple analyte signals from a single MPS measurement, but its performance critically depends on the choice of harmonic components used for decoding. In practical multiplexed MPS bioassays, numerical instability in solving harmonic equations directly translates into analyte misquantification and degrades assay performance. Despite significant progress, there is currently no systematic framework to guide the selection of harmonic sets that maximize spectral separation accuracy across different mixture complexities. Herein, we systematically investigate truncated spectral separation across binary, ternary, and quaternary mixtures of distinct magnetic nanoparticle labels by evaluating a wide range of harmonic component combinations under identical experimental conditions. We demonstrate that the absolute determinant of the truncated reference matrix serves as a robust and effective criterion for identifying harmonic sets that yield the lowest decoding error under the evaluated experimental conditions. The proposed harmonic selection framework is demonstrated to be effective across multiple decoding strategies and provides practical design guidance for robust and scalable multiplexed MPS bioassays.
- 22 May 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (20) , 205001
Open AccessA systematic framework for harmonic set selection in multiplexed magnetic particle spectroscopy
Magnetic particle spectroscopy (MPS) has emerged as a powerful biosensing modality due to its high sensitivity, matrix-free detection, and compatibility with point-of-care diagnostics. However, the lack of robust multiplexing capability remains a major bottleneck that limits its broader application in complex bioassays. To address this challenge, spatial and spectral separation strategies have been explored in recent years. While spatial separation approaches enable multiplexing without sacrificing sensitivity, they require physically distinct assay regions and substantially increase assay complexity, cost, and reagent consumption. In contrast, spectral separation offers a more resource-efficient solution by decoding multiple analyte signals from a single MPS measurement, but its performance critically depends on the choice of harmonic components used for decoding. In practical multiplexed MPS bioassays, numerical instability in solving harmonic equations directly translates into analyte misquantification and degrades assay performance. Despite significant progress, there is currently no systematic framework to guide the selection of harmonic sets that maximize spectral separation accuracy across different mixture complexities. Herein, we systematically investigate truncated spectral separation across binary, ternary, and quaternary mixtures of distinct magnetic nanoparticle labels by evaluating a wide range of harmonic component combinations under identical experimental conditions. We demonstrate that the absolute determinant of the truncated reference matrix serves as a robust and effective criterion for identifying harmonic sets that yield the lowest decoding error under the evaluated experimental conditions. The proposed harmonic selection framework is demonstrated to be effective across multiple decoding strategies and provides practical design guidance for robust and scalable multiplexed MPS bioassays.
- Open Access
- 16 March 2026
- Published by IOP Publishing in Nanotechnology
- Vol. 37 (11) , 115701
Data-driven and physics-informed estimation of magnetic nanoparticle properties via stochastic Langevin model
The dynamic magnetization of magnetic nanoparticles (MNPs) arises from coupled Néel and Brownian relaxations, which are influenced by intrinsic particle properties such as size, saturation magnetization, magnetic anisotropy, and damping. While experimental AC magnetization measurements can reveal the collective dynamic behavior of MNP ensembles, extracting accurate nanoparticle-specific parameters from such data remains a challenge due to experimental limitations and model oversimplifications. To address this, we apply a stochastic Langevin model that explicitly captures the time-dependent magnetization response of MNPs under alternating magnetic fields by incorporating both thermal fluctuations and stochastic relaxation processes. This model provides a physically grounded framework for simulating magnetization hysteresis under experimental conditions, enabling parameter estimation through direct data fitting. In this work, we fit the stochastic Langevin model to experimentally measured hysteresis loops of different MNPs collected under a 20 mT, 5 kHz AC field. By coupling the model with Bayesian optimization and Gaussian process regression, we identify optimal values of key magnetic parameters: saturation magnetization ( M s ), effective anisotropy ( K a ), and Gilbert damping parameter ( α ). Furthermore, the M s is experimentally measured and employed as a validation parameter. Accordingly, the determination of the α and the K a is based on two complementary criteria: (1) the best agreement between the simulated and experimental AC response magnetization hysteresis loops, quantified by the coefficient of determination ( R 2 ), and (2) the closest correspondence between the estimated and experimentally measured M s values, evaluated using the mean absolute percentage error. Our approach is validated on four commercial MNP products (SHS30, IPG30, SHP25, and SHP15, from Ocean Nanotech, LLC), yielding high-fidelity fits to experimental data and robust estimation of their magnetic properties.
- 16 March 2026
- Published by IOP Publishing in Nanotechnology
- Vol. 37 (11) , 115701
Open AccessData-driven and physics-informed estimation of magnetic nanoparticle properties via stochastic Langevin model
The dynamic magnetization of magnetic nanoparticles (MNPs) arises from coupled Néel and Brownian relaxations, which are influenced by intrinsic particle properties such as size, saturation magnetization, magnetic anisotropy, and damping. While experimental AC magnetization measurements can reveal the collective dynamic behavior of MNP ensembles, extracting accurate nanoparticle-specific parameters from such data remains a challenge due to experimental limitations and model oversimplifications. To address this, we apply a stochastic Langevin model that explicitly captures the time-dependent magnetization response of MNPs under alternating magnetic fields by incorporating both thermal fluctuations and stochastic relaxation processes. This model provides a physically grounded framework for simulating magnetization hysteresis under experimental conditions, enabling parameter estimation through direct data fitting. In this work, we fit the stochastic Langevin model to experimentally measured hysteresis loops of different MNPs collected under a 20 mT, 5 kHz AC field. By coupling the model with Bayesian optimization and Gaussian process regression, we identify optimal values of key magnetic parameters: saturation magnetization ( M s ), effective anisotropy ( K a ), and Gilbert damping parameter ( α ). Furthermore, the M s is experimentally measured and employed as a validation parameter. Accordingly, the determination of the α and the K a is based on two complementary criteria: (1) the best agreement between the simulated and experimental AC response magnetization hysteresis loops, quantified by the coefficient of determination ( R 2 ), and (2) the closest correspondence between the estimated and experimentally measured M s values, evaluated using the mean absolute percentage error. Our approach is validated on four commercial MNP products (SHS30, IPG30, SHP25, and SHP15, from Ocean Nanotech, LLC), yielding high-fidelity fits to experimental data and robust estimation of their magnetic properties.
- Open Access
- 19 February 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2) , 022001
Magnetic nanoparticles for cancer theranostics
Magnetic nanoparticles (MNPs) have emerged as a powerful tool in cancer theranostics due to their unique size-dependent magnetic properties, surface functionalization capabilities, and responsiveness to external magnetic fields. This review outlines different types of MNPs, including those composed of pure metals, metal oxides, and metallic alloys, and highlights their size-dependent magnetic behavior, such as superparamagnetism and dynamic magnetizations. We also explore the critical role of surface modification strategies in enhancing MNPs’ biocompatibility, colloidal stability, and functional versatility for targeted biomedical applications. The applications of MNPs in cancer therapy are discussed, with a focus on magnetic hyperthermia, drug and gene delivery, and a combination of various therapies. Additionally, we examine their cancer diagnostic roles in imaging techniques such as magnetic resonance imaging (MRI) and magnetic particle imaging (MPI), and emerging magnetic biosensing technologies such as giant magnetoresistance (GMR), magnetic tunnel junction (MTJ), magnetic particle spectroscopy (MPS), and nuclear magnetic resonance (NMR)-based platforms. These advances collectively establish MNPs as key components in the future of personalized cancer diagnosis and treatment.
- 19 February 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2) , 022001
Open AccessMagnetic nanoparticles for cancer theranostics
Magnetic nanoparticles (MNPs) have emerged as a powerful tool in cancer theranostics due to their unique size-dependent magnetic properties, surface functionalization capabilities, and responsiveness to external magnetic fields. This review outlines different types of MNPs, including those composed of pure metals, metal oxides, and metallic alloys, and highlights their size-dependent magnetic behavior, such as superparamagnetism and dynamic magnetizations. We also explore the critical role of surface modification strategies in enhancing MNPs’ biocompatibility, colloidal stability, and functional versatility for targeted biomedical applications. The applications of MNPs in cancer therapy are discussed, with a focus on magnetic hyperthermia, drug and gene delivery, and a combination of various therapies. Additionally, we examine their cancer diagnostic roles in imaging techniques such as magnetic resonance imaging (MRI) and magnetic particle imaging (MPI), and emerging magnetic biosensing technologies such as giant magnetoresistance (GMR), magnetic tunnel junction (MTJ), magnetic particle spectroscopy (MPS), and nuclear magnetic resonance (NMR)-based platforms. These advances collectively establish MNPs as key components in the future of personalized cancer diagnosis and treatment.
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 9 (3) , 351-359
Extending the MaRCoS: A 4-Rx Open-Source MRI Console for Low-, Mid-, and High-Field Systems
The fast advancement of low-field MRI (magnetic resonance imaging) has generated a high demand for cost-effective and versatile consoles for MRI scanners. MaRCoS (MAgnetic Resonance COntrol System) is such an open-source system that has been well-tested on various low-field systems. However, due to limitations of the basic hardware, MaRCoS is constrained in its ability to support a wide range of field strengths and RF (radio-frequency) channels. In this study, we aim to port the MaRCoS console to high-field (up to 125 MHz Larmor frequency) MRI systems and increase the number of RF receive channels, enabling phased-array coils and/or active EMI (electromagnetic interference) elimination techniques. A series of implementations were conducted across 0.11-, 0.5-, and 1.5-Tesla MRI systems, to evaluate its compatibility and performance. Promising results indicate that the extended console not only matches but, to some extent, surpasses the performance of a commercial console, particularly in terms of flexibility and accessibility. It is hoped that this study could effectively expand the scope of open-source MRI technology, making MRI scans more accessible and affordable.
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 9 (3) , 351-359
Extending the MaRCoS: A 4-Rx Open-Source MRI Console for Low-, Mid-, and High-Field Systems
The fast advancement of low-field MRI (magnetic resonance imaging) has generated a high demand for cost-effective and versatile consoles for MRI scanners. MaRCoS (MAgnetic Resonance COntrol System) is such an open-source system that has been well-tested on various low-field systems. However, due to limitations of the basic hardware, MaRCoS is constrained in its ability to support a wide range of field strengths and RF (radio-frequency) channels. In this study, we aim to port the MaRCoS console to high-field (up to 125 MHz Larmor frequency) MRI systems and increase the number of RF receive channels, enabling phased-array coils and/or active EMI (electromagnetic interference) elimination techniques. A series of implementations were conducted across 0.11-, 0.5-, and 1.5-Tesla MRI systems, to evaluate its compatibility and performance. Promising results indicate that the extended console not only matches but, to some extent, surpasses the performance of a commercial console, particularly in terms of flexibility and accessibility. It is hoped that this study could effectively expand the scope of open-source MRI technology, making MRI scans more accessible and affordable.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (7) , 2095-2104
Inter-Channel Correlation-Based EMI Noise Removal (ICER) for Shielding-Free Low-Field MRI
Objective: For low-field magnetic resonance imaging (MRI) in unshielded environment, existing methods have been proposed to eliminate electromagnetic interference (EMI) noise in each single radio-frequency (RF) receive coil. In the present study, we propose to use the EMI information from multiple MRI receive coils collectively in EMI denoising. Methods: The proposed method leverages the information of inter-channel correlation, including EMI detectors and RF receive coils to remove EMI noise. Calibration signals from both EMI detectors and RF receivers are concatenated to determine a de-correlation matrix, which is then used to denoise MRI signals. Results: Saline phantom and in vivo experiments demonstrated the efficacy of the proposed method in EMI elimination, showing that the proposed method outperformed advanced EMI elimination methods with up to 16.34% improvement in EMI noise removal percentage (NRP) and 1.58dB improvement in signal-to-noise ratio (SNR), along with reduced computational time. Conclusion: The proposed method effectively removes EMI noise and shows improved performance by using information from all receive coils. Significance: This method allows for the design of multi-receive coils for low-field MRI such as phased-arrays, which have the potential to enhance the performance in noise removal and improve the SNR in MRI signal acquisition.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (7) , 2095-2104
Inter-Channel Correlation-Based EMI Noise Removal (ICER) for Shielding-Free Low-Field MRI
Objective: For low-field magnetic resonance imaging (MRI) in unshielded environment, existing methods have been proposed to eliminate electromagnetic interference (EMI) noise in each single radio-frequency (RF) receive coil. In the present study, we propose to use the EMI information from multiple MRI receive coils collectively in EMI denoising. Methods: The proposed method leverages the information of inter-channel correlation, including EMI detectors and RF receive coils to remove EMI noise. Calibration signals from both EMI detectors and RF receivers are concatenated to determine a de-correlation matrix, which is then used to denoise MRI signals. Results: Saline phantom and in vivo experiments demonstrated the efficacy of the proposed method in EMI elimination, showing that the proposed method outperformed advanced EMI elimination methods with up to 16.34% improvement in EMI noise removal percentage (NRP) and 1.58dB improvement in signal-to-noise ratio (SNR), along with reduced computational time. Conclusion: The proposed method effectively removes EMI noise and shows improved performance by using information from all receive coils. Significance: This method allows for the design of multi-receive coils for low-field MRI such as phased-arrays, which have the potential to enhance the performance in noise removal and improve the SNR in MRI signal acquisition.
- Open Access
- 29 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Function Extension and Implementation of MaRCoS in Low-, Mid-, and High-Field MRI Systems: A Technical Report
The fast advancement of low-field MRI (magnetic resonance imaging) has generated a high demand for costeffective and versatile consoles for MRI scanners. MaRCoS (MAgnetic Resonance COntrol System) is such an open-source system that has been well-tested on various low-field systems. However, due to limitations of the basic hardware, MaRCoS is constrained in its ability to support a wide range of field strengths and RF (radio-frequency) channels. In this study, we aim to port the MaRCoS console to high-field MRI systems and increase the number of RF receive channels, enabling phased-array coils and/or active EMI (electromagnetic interference) elimination techniques. A series of implementations were conducted across 0.11-, 0.5-, and 1.5-Telsa MRI systems, in order to evaluate its compatibility and performance. Promising results indicate that the extended console not only matches but, to some extent, surpasses the performance of a commercial spectrometer, particularly in terms of flexibility and accessibility. It is hoped that this study could effectively expand the scope of open-source MRI technology, making MRI scans more accessible and affordable.
- 29 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessFunction Extension and Implementation of MaRCoS in Low-, Mid-, and High-Field MRI Systems: A Technical Report
The fast advancement of low-field MRI (magnetic resonance imaging) has generated a high demand for costeffective and versatile consoles for MRI scanners. MaRCoS (MAgnetic Resonance COntrol System) is such an open-source system that has been well-tested on various low-field systems. However, due to limitations of the basic hardware, MaRCoS is constrained in its ability to support a wide range of field strengths and RF (radio-frequency) channels. In this study, we aim to port the MaRCoS console to high-field MRI systems and increase the number of RF receive channels, enabling phased-array coils and/or active EMI (electromagnetic interference) elimination techniques. A series of implementations were conducted across 0.11-, 0.5-, and 1.5-Telsa MRI systems, in order to evaluate its compatibility and performance. Promising results indicate that the extended console not only matches but, to some extent, surpasses the performance of a commercial spectrometer, particularly in terms of flexibility and accessibility. It is hoped that this study could effectively expand the scope of open-source MRI technology, making MRI scans more accessible and affordable.