EAEbrahim Azizi

Ebrahim Azizi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ebrahim Azizi has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Perspective: magnetic tunnel junctions for in-sensor computing

    by Kai Wu, Ebrahim Azizi, Niranjan A Natekar, Hanlei Wang, Yingying Wu, Rui He

    Large-area sensing systems, such as biomedical imaging, nondestructive evaluation, current mapping, soft robotics, and distributed internet-of-things monitoring, generate massive spatial and temporal data streams that are costly to digitize, transfer, and process using conventional sensor-processor architectures. In-sensor computing offers a promising route to overcome this bottleneck by moving early-stage computation directly to the sensing front end, thereby reducing data movement, latency, and power consumption. Magnetic tunnel junctions (MTJs) are uniquely positioned for this emerging paradigm because they combine magnetic field sensitivity, nonvolatile resistance states, CMOS compatibility, fast spintronic dynamics, stochastic switching, and low-standby-power operation. These properties allow MTJs to function not only as magnetic sensors or memory cells, but also as stateful computing elements. This perspective discusses recent progress in MTJ-based computing and outlines how these advances can guide the development of next-generation MTJ-based in-sensor computing. We first review the working principles of MTJs and their use in basic logic functions, including reconfigurable Boolean logic, logic-in-memory, and reliability considerations. We then discuss MTJ implementations of neural network primitives, including feedforward neural networks, convolutional neural networks, recurrent neural networks, and spiking neural networks, highlighting how nonlinear magnetization dynamics, oscillatory behavior, and probabilistic switching can support neuromorphic computation. Finally, we examine emerging magnetic near-sensor, multifunctional MTJ, and VC-MTJ processing-in-pixel concepts and identify key challenges for future MTJ sensor-computing arrays. We argue that the next major opportunity is to engineer large-area MTJ sensor arrays that perform local thresholding, event detection, feature extraction, and compressed readout directly at the magnetic sensing interface.

  • Dual-functional magnetic nanoparticles: A stochastic Langevin study of imaging-heating trade-offs

    by Ebrahim Azizi, Hanlei Wang, Hansong Zuo, Vinit Kumar Chugh, Rui He, Kai Wu

    Magnetic nanoparticles (MNPs) are central to magnetic particle imaging (MPI) and magnetic hyperthermia. The intrinsic properties of MNPs critically determine the performance of each modality individually. The integration of imaging and therapy within a single MPI-hyperthermia platform is especially attractive, as it enables mapping of MNP tracer distribution using MPI prior to thermal treatment, thereby guiding the subsequent delivery of localized hyperthermia. In such dual-functional systems, however, nanoparticle properties play a more complex and potentially different role than in standalone applications. Understanding how these intrinsic characteristics govern the sequential imaging and heating performance within a unified platform is therefore essential for the rational design of effective theranostic systems. Nevertheless, the impact of the nanoparticles' inherent characteristics on achieving optimal imaging and heating performance across both imaging and therapeutic stages has not yet been thoroughly investigated. In this work, we present a comprehensive modeling-based framework to optimize dual-functional MPI-hyperthermia performance by systematically investigating three MNP core sizes (20, 25, and 30 nm) over broad ranges of anisotropy constants and saturation magnetizations using a stochastic Langevin model. Magnetization dynamics are evaluated at 25 kHz (for MPI use) and 350 kHz (for hyperthermia use) alternating magnetic fields. Performance is quantified using the full width at half-maximum and signal-to-noise ratio to assess MPI spatial resolution and signal quality, respectively, and the specific absorption rate to evaluate hyperthermia efficiency. The competing behavior of these performance metrics is first analyzed through direct visualization of the simulated data, revealing clear trade-offs between spatial resolution, signal quality, and heating efficiency. To capture the underlying nonlinear relationships more rigorously, Gaussian process surrogate models are constructed for each metric and validated for predictive accuracy. Building on these models, a multiobjective optimization framework is employed to identify optimal combinations of anisotropy constant and saturation magnetization for each core size that balance MPI and hyperthermia performance. The results demonstrate a strong dependence of the optimal parameter regions on MNP core size, with distinct trade-offs emerging between imaging and therapeutic objectives. This study provides a systematic and extensible framework for the rational design of dual-functional MNPs and offers quantitative guidance for optimizing particle properties in combined MPI-guided magnetic hyperthermia applications.

  • Open Access

    A systematic framework for harmonic set selection in multiplexed magnetic particle spectroscopy

    by Hanlei Wang, Vinit Kumar Chugh, Ebrahim Azizi, Hansong Zuo, Rui He, Kai Wu

    Magnetic particle spectroscopy (MPS) has emerged as a powerful biosensing modality due to its high sensitivity, matrix-free detection, and compatibility with point-of-care diagnostics. However, the lack of robust multiplexing capability remains a major bottleneck that limits its broader application in complex bioassays. To address this challenge, spatial and spectral separation strategies have been explored in recent years. While spatial separation approaches enable multiplexing without sacrificing sensitivity, they require physically distinct assay regions and substantially increase assay complexity, cost, and reagent consumption. In contrast, spectral separation offers a more resource-efficient solution by decoding multiple analyte signals from a single MPS measurement, but its performance critically depends on the choice of harmonic components used for decoding. In practical multiplexed MPS bioassays, numerical instability in solving harmonic equations directly translates into analyte misquantification and degrades assay performance. Despite significant progress, there is currently no systematic framework to guide the selection of harmonic sets that maximize spectral separation accuracy across different mixture complexities. Herein, we systematically investigate truncated spectral separation across binary, ternary, and quaternary mixtures of distinct magnetic nanoparticle labels by evaluating a wide range of harmonic component combinations under identical experimental conditions. We demonstrate that the absolute determinant of the truncated reference matrix serves as a robust and effective criterion for identifying harmonic sets that yield the lowest decoding error under the evaluated experimental conditions. The proposed harmonic selection framework is demonstrated to be effective across multiple decoding strategies and provides practical design guidance for robust and scalable multiplexed MPS bioassays.


  • Top Cited Papers
    Open Access

    Magnetic nanoparticle contrast agents for MRI: structure-property relationships, in vivo applications, and future theranostic directions

    by Bahareh Rezaei, Shahriar Mostufa, Karla Mercedes Paz González, Ebrahim Azizi, Changzhi Li, Jenifer Gómez-Pastora, Rui He, Kai Wu

    Magnetic resonance imaging (MRI) is a non-invasive and non-ionizing imaging modality that provides high-resolution images of internal organs such as the breast, brain, and cardiovascular system, enabling three-dimensional visualization of soft tissues. While MRI offers excellent soft tissue contrast, its sensitivity can be further enhanced using contrast agents, and many clinical applications rely on exogenous agents to improve detection and diagnostic accuracy. Two primary classes are used clinically: paramagnetic substances, exemplified by gadolinium (Gd), which predominantly shorten longitudinal ( T 1 ) relaxation, and superparamagnetic iron oxide nanoparticles (SPIONs), which exert strong effects on transverse ( T 2 ) relaxation. The performance and safety of these agents are strongly influenced by their pharmacokinetics and biodistribution, including rapid recognition and clearance by the reticuloendothelial system, which can both enable liver–spleen imaging and limit target-specific contrast in other organs. In this review, we first summarize the fundamental principles of MRI contrast generation, with an emphasis on relaxation mechanisms relevant to magnetic nanoparticles (MNPs). We then discuss the use of MNPs as contrast agents in representative biomedical applications, focusing on cardiac, breast, and brain MRI and illustrating how organ-specific physiology constrains nanoparticle design and performance. Finally, we examine biocompatibility and safety considerations for both Gd-based agents and SPIONs, highlighting current regulatory concerns, open questions regarding long-term toxicity, and key challenges that must be addressed to translate next-generation nanoparticle-based MRI contrast agents into routine clinical practice.


  • Open Access

    Data-driven and physics-informed estimation of magnetic nanoparticle properties via stochastic Langevin model

    by Ebrahim Azizi, Hanlei Wang, Hansong Zuo, Vinit Chugh, Rui He, Kai Wu

    The dynamic magnetization of magnetic nanoparticles (MNPs) arises from coupled Néel and Brownian relaxations, which are influenced by intrinsic particle properties such as size, saturation magnetization, magnetic anisotropy, and damping. While experimental AC magnetization measurements can reveal the collective dynamic behavior of MNP ensembles, extracting accurate nanoparticle-specific parameters from such data remains a challenge due to experimental limitations and model oversimplifications. To address this, we apply a stochastic Langevin model that explicitly captures the time-dependent magnetization response of MNPs under alternating magnetic fields by incorporating both thermal fluctuations and stochastic relaxation processes. This model provides a physically grounded framework for simulating magnetization hysteresis under experimental conditions, enabling parameter estimation through direct data fitting. In this work, we fit the stochastic Langevin model to experimentally measured hysteresis loops of different MNPs collected under a 20 mT, 5 kHz AC field. By coupling the model with Bayesian optimization and Gaussian process regression, we identify optimal values of key magnetic parameters: saturation magnetization ( M s ), effective anisotropy ( K a ), and Gilbert damping parameter ( α ). Furthermore, the M s is experimentally measured and employed as a validation parameter. Accordingly, the determination of the α and the K a is based on two complementary criteria: (1) the best agreement between the simulated and experimental AC response magnetization hysteresis loops, quantified by the coefficient of determination ( R 2 ), and (2) the closest correspondence between the estimated and experimentally measured M s values, evaluated using the mean absolute percentage error. Our approach is validated on four commercial MNP products (SHS30, IPG30, SHP25, and SHP15, from Ocean Nanotech, LLC), yielding high-fidelity fits to experimental data and robust estimation of their magnetic properties.

  • Open Access

    Magnetic nanoparticles for cancer theranostics

    by Jaiden Hart, Linh Nguyen T Tran, Tamara Faranaz Ena, Niranjan A Natekar, Bahareh Rezaei, Yipeng Jiao, Hansong Zuo, Hanlei Wang, Vinit Chugh, Ebrahim Azizi, et al.

    Magnetic nanoparticles (MNPs) have emerged as a powerful tool in cancer theranostics due to their unique size-dependent magnetic properties, surface functionalization capabilities, and responsiveness to external magnetic fields. This review outlines different types of MNPs, including those composed of pure metals, metal oxides, and metallic alloys, and highlights their size-dependent magnetic behavior, such as superparamagnetism and dynamic magnetizations. We also explore the critical role of surface modification strategies in enhancing MNPs’ biocompatibility, colloidal stability, and functional versatility for targeted biomedical applications. The applications of MNPs in cancer therapy are discussed, with a focus on magnetic hyperthermia, drug and gene delivery, and a combination of various therapies. Additionally, we examine their cancer diagnostic roles in imaging techniques such as magnetic resonance imaging (MRI) and magnetic particle imaging (MPI), and emerging magnetic biosensing technologies such as giant magnetoresistance (GMR), magnetic tunnel junction (MTJ), magnetic particle spectroscopy (MPS), and nuclear magnetic resonance (NMR)-based platforms. These advances collectively establish MNPs as key components in the future of personalized cancer diagnosis and treatment.


  • Open Access

    Visual Perception and Sensory Engagement in ASMR Videos: An Affective Computing Perspective

    by Sahar Seifzadeh, Ebrahim Azizi, Majid Behzadpour, Kai Wu, Bożena Kostek

    Autonomous Sensory Meridian Response (ASMR) is an audiovisual phenomenon characterized by tingling sensations and deep relaxation triggered by whispering, tapping, facial expressions, and hand gestures. While previous research has focused mainly on the acoustic features of ASMR, its visual dimension remains critically understudied despite being central to the multisensory experience. This paper presents the first comprehensive computational investigation of key visual triggers in ASMR videos. To the best of our knowledge, no prior work has quantitatively analyzed visual features in ASMR; existing studies address only auditory triggers or offer only qualitative commentary. Using a multimodal framework that integrates temporal color variance, motion dynamics, and three-dimensional facial and hand landmark modeling, we identify the visual components that differentiate highly engaging ASMR content from less engaging material. Our results show that stable facial expressions and hand postures enhance social presence and emotional comfort, while dynamic variations in motion and color reflect stylistic differences across creators. These visual patterns shape viewer engagement in ways linked to both performer style and audience psychological preferences. More broadly, our findings offer a quantitative foundation for optimizing the visual design of ASMR and other calming audiovisual media used for relaxation and affective regulation.


  • Open Access

    Effects of excitation field amplitude on magnetic particle imaging performance: a modeling study

    by Ebrahim Azizi, Changzhi Li, Jenifer Gómez-Pastora, Rui He, Kai Wu

    Magnetic particle imaging (MPI) is a new tomographic imaging technique that can quantitatively correlate MPI signal intensity to the spatial distribution of magnetic nanoparticle (MNP) tracers. Due to its non-ionizing nature, low background signal from biological matrices, high contrast, and relatively good spatial and temporal resolution, MPI has been actively studied and applied to biomedical imaging and is expected to reach the clinical stage soon. To further improve the spatial resolution limit in MPI, researchers have been working towards optimizing the image reconstruction algorithms, magnetic field profiles, tracer designs, circuitry, etc. Recent studies reported that lower excitation field amplitudes can improve spatial resolution, though this comes at the expense of lower MPI signal and tracer sensitivity. Different excitation field profiles directly affect the collective dynamic magnetizations of tracers recorded by the receiver coil in MPI. However, there is a gap between understanding the relaxation dynamics of MNP tracers, the signal-to-noise ratio (SNR) of MPI signals, and the MPI spatial resolution. In this work, we used a stochastic Langevin equation with coupled Brownian and Néel relaxations to model the magnetic dynamics of different MNP tracers subjected to varying excitation fields. We analyzed the collective time-domain dynamic magnetizations (M–t curves), magnetic-field hysteresis loops (M-H curves), point spread functions (PSFs), higher harmonics, and SNR of the third harmonic to understand how the excitation field affects MPI performance. We employed Full Width at Half Maximum and SNR as evaluation metrics for imaging resolution and signal quality, respectively. Our study supports previous findings on the impact of excitation field amplitude on MPI performance while offering more profound insights into the interplay of nonequilibrium Néel and Brownian relaxation, tracer core size, and SNR.


  • Open Access

    Characterizing the physicochemical properties of magnetic nanoparticles by a surface plasmon resonance approach

    by Shahriar Mostufa, Bahareh Rezaei, Ebrahim Azizi, Yongqiang Andrew Wang, Changzhi Li, Jenifer Gómez-Pastora, Rui He, Kai Wu

    Magnetic nanoparticles (MNPs) are widely recognized as effective signal amplifiers for surface plasmon resonance (SPR)-based biosensors. Herein, we report that SPR sensors can be a useful tool to characterize the physicochemical properties of surface-functionalized iron oxide MNPs. In this work, a Kretschmann configuration-based SPR sensing platform with a scanning angular range of up to 17° is employed to identify the resonance conditions of different MNP suspensions. We demonstrate the feasibility of SPR for differentiating different surface coatings on the iron oxide MNPs, such as amine, biotin, and streptavidin, as well as distinguishing different magnetic core sizes (from 15 nm to 30 nm) and nanoparticle concentrations (from 0.013 mg/ml to 2.5 mg/ml). The SPR resonance angle shift, Δθ, is used as a crucial parameter for characterizing these physicochemical properties of MNPs floating within the surface of the metal layer that can directly interact with the surface plasmons, and the variation of their physicochemical properties is the reason causing a shift in the SPR resonance angle.


  • Open Access

    Numerical analysis of hybrid electromagnetic coil designs for efficient gradient field generation in magnetic particle imaging

    by Shahriar Mostufa, Ebrahim Azizi, Bahareh Rezaei, Changzhi Li, Jenifer Gómez-Pastora, Rui He, Kai Wu

    Magnetic particle imaging (MPI) is an emerging tomographic imaging modality that has shown great potential for cell tracking, tumor imaging, gut bleeding, etc. As MPI moves towards clinical applications, one challenge faced by this technology is the increasing power consumption for field generation as the bore size increases. Joining the efforts in transitioning MPI to clinical applications, especially for human-sized MPI. Herein, using COMSOL Multiphysics, we numerically studied three coil designs for generating high gradient fields with high field uniformity at lower power consumption. Specifically, the Maxwell electromagnetic (EM) coils, the hybrid EM coils with an NdFeB magnet core, and the hybrid EM coils with an NdFeB magnet core designed as a magnetic flux concentrator (MFC). We first compared the efficiency of these three coil designs in generating gradient fields by evaluating the maximum gradient field strength and field uniformity. With the same current applied to these coils, the hybrid EM coils with a NdFeB MFC core show the best gradient field profiles, achieving a maximum gradient field strength of 5 T/m. The current supplied to these EM coils and the coil winding layers are varied to study their effects on the gradient field profiles. Additionally, the geometrical parameter of the MFC structure is optimized, and we have achieved a maximum gradient field strength of 5 T/m over a 14.3 cm space, with a tolerance of 98%.