Jennifer Christensen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jennifer Christensen has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Rubens Spin-Neto
Section for Oral Radiology and Endodontics, Department of Dentistry and Oral Health Aarhus University Aarhus Denmark
8 shared publications Louise Hauge Matzen
Section for Oral Radiology and Endodontics, Department of Dentistry and Oral Health, Aarhus University, 8000 Aarhus, Denmark
5 shared publications- Lise‐Lotte Kirkevang
Department of Dentistry and Oral Health Aarhus University Aarhus Denmark
4 shared publications - Ann Wenzel
Section for Oral Radiology, Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark
2 shared publications - Gabriela Salatino Liedke
Department of Stomatology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
2 shared publications - Louise Hauge Matzen
Section for Oral Radiology and Endodontics, Department of Dentistry and Oral Health, Aarhus, University , Aarhus 8000
2 shared publications
Latest Publications
- Open Access
- 13 July 2026
- Published by Elsevier in Journal of Endodontics
- Vol. 52 (10) , 1605-1612
Feasibility of a Shortened Dental-dedicated Magnetic Resonance Imaging Acquisition Protocol for Dentomaxillofacial Imaging: A Pilot Study
- 13 July 2026
- Published by Elsevier in Journal of Endodontics
- Vol. 52 (10) , 1605-1612
Open AccessFeasibility of a Shortened Dental-dedicated Magnetic Resonance Imaging Acquisition Protocol for Dentomaxillofacial Imaging: A Pilot Study
- 11 July 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
Patient experience and movement frequency in young children during simulated ddMRI examinations
Objectives: To assess the feasibility of dental-dedicated MRI (ddMRI), a non-ionizing imaging modality, for scanning children and to explore associations between age, sex, perceived experience, and movement during scanning. Methods: Thirty-seven children age 8-14 underwent a mock ddMRI examination simulating the scan of an impacted canine (5 pulse sequences, total scan time 12’27 min) using a 0.55 T scanner and a dedicated dental radiofrequency surface coil. Perceived patient experience was recorded using a 5-point visual analogue scale (VAS) before and after the examination. Movements of the head and body were quantified and characterized from video recordings of the scan. Multiple linear regression analyses were applied to evaluate associations between log-transformed movement and age, sex, and VAS scores. Separate regression models were applied for pre- and post-scan VAS. Significance level was set at .05. Results: Number of movements during scan time was registered for the head separately (mean/median 6.3/0, range 0-82) and for the body in total (62/34, 0-430). Increased head movement was significantly associated with younger age (34%/year, P = .010). Overall movement was significantly associated with sex (M > F, 24.8% more movement, P = .010). Pre-scan VAS (mean/median 1.73/2, range 1-3) decreased significantly with increasing age (0.21 points/year, P = .035). Post-scan VAS (1.95/2, 1-3) was significantly higher in girls than in boys (0.6 points/year, P = .031). Conclusion: Age and sex influence the child’s experience and the number of movements during the mock scan. ddMRI may prove to be a feasible method for scanning children in a dental setting, offering a comfortable experience without ionizing radiation. Advances in knowledge: This article is the first to demonstrate the applicability of ddMRI in a pediatric population, thereby laying the groundwork for future research into its use in diagnosis and treatment planning for children and adolescents
- 11 July 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
Patient experience and movement frequency in young children during simulated ddMRI examinations
Objectives: To assess the feasibility of dental-dedicated MRI (ddMRI), a non-ionizing imaging modality, for scanning children and to explore associations between age, sex, perceived experience, and movement during scanning. Methods: Thirty-seven children age 8-14 underwent a mock ddMRI examination simulating the scan of an impacted canine (5 pulse sequences, total scan time 12’27 min) using a 0.55 T scanner and a dedicated dental radiofrequency surface coil. Perceived patient experience was recorded using a 5-point visual analogue scale (VAS) before and after the examination. Movements of the head and body were quantified and characterized from video recordings of the scan. Multiple linear regression analyses were applied to evaluate associations between log-transformed movement and age, sex, and VAS scores. Separate regression models were applied for pre- and post-scan VAS. Significance level was set at .05. Results: Number of movements during scan time was registered for the head separately (mean/median 6.3/0, range 0-82) and for the body in total (62/34, 0-430). Increased head movement was significantly associated with younger age (34%/year, P = .010). Overall movement was significantly associated with sex (M > F, 24.8% more movement, P = .010). Pre-scan VAS (mean/median 1.73/2, range 1-3) decreased significantly with increasing age (0.21 points/year, P = .035). Post-scan VAS (1.95/2, 1-3) was significantly higher in girls than in boys (0.6 points/year, P = .031). Conclusion: Age and sex influence the child’s experience and the number of movements during the mock scan. ddMRI may prove to be a feasible method for scanning children in a dental setting, offering a comfortable experience without ionizing radiation. Advances in knowledge: This article is the first to demonstrate the applicability of ddMRI in a pediatric population, thereby laying the groundwork for future research into its use in diagnosis and treatment planning for children and adolescents
- Open Access
- 2 July 2026
- Published by Springer Nature in Oral Radiology
- Vol. 42 (4) , 1287-1294
Follow-up of periapical inflammation after root canal retreatment and surgical endodontic treatment using dental-dedicated magnetic resonance imaging: a case report
The aim is to present a dental-dedicated magnetic resonance imaging (ddMRI)-based diagnosis and follow-up in a clinical case of apical periodontitis (AP) on a root canal treated (RCT) tooth. Persistent AP in RCT teeth can be difficult to distinguish from scar tissue or incomplete healing. In the absence of symptoms, no currently known imaging method can verify the presence of inflammation. ddMRI is a novel imaging modality proposed for dentistry, that has the potential to reveal inflammation. A 50-year-old male presented with mild symptoms from a previously RCT 36. ddMRI suggested mild inflammation, and an intraoral image revealed a periapical radiolucency. The tooth was non-surgically endodontically retreated. During follow-up, no exacerbation of the inflammation was detected on ddMRI. However, one year after retreatment, a periapical radiolucency persisted, and the ddMRI indicated that the inflammation had not resolved. Surgical endodontic retreatment was performed, and a tissue sample was retrieved from the periapical area. A histopathological analysis revealed inflammation as suspected from the hyperintense signal seen on ddMRI. Despite treatment, the inflammation did not resolve, and after development of a fistula, the tooth was extracted.
- 2 July 2026
- Published by Springer Nature in Oral Radiology
- Vol. 42 (4) , 1287-1294
Open AccessFollow-up of periapical inflammation after root canal retreatment and surgical endodontic treatment using dental-dedicated magnetic resonance imaging: a case report
The aim is to present a dental-dedicated magnetic resonance imaging (ddMRI)-based diagnosis and follow-up in a clinical case of apical periodontitis (AP) on a root canal treated (RCT) tooth. Persistent AP in RCT teeth can be difficult to distinguish from scar tissue or incomplete healing. In the absence of symptoms, no currently known imaging method can verify the presence of inflammation. ddMRI is a novel imaging modality proposed for dentistry, that has the potential to reveal inflammation. A 50-year-old male presented with mild symptoms from a previously RCT 36. ddMRI suggested mild inflammation, and an intraoral image revealed a periapical radiolucency. The tooth was non-surgically endodontically retreated. During follow-up, no exacerbation of the inflammation was detected on ddMRI. However, one year after retreatment, a periapical radiolucency persisted, and the ddMRI indicated that the inflammation had not resolved. Surgical endodontic retreatment was performed, and a tissue sample was retrieved from the periapical area. A histopathological analysis revealed inflammation as suspected from the hyperintense signal seen on ddMRI. Despite treatment, the inflammation did not resolve, and after development of a fistula, the tooth was extracted.
- 15 May 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (6) , 636-644
Lingual nerve visualization with dental-dedicated MRI: feasibility and observer reproducibility
Objective: To evaluate the feasibility of lingual nerve visualization using dental-dedicated MRI (ddMRI), with emphasis on observer reproducibility in a patient series. Methods: Twenty consecutive healthy volunteers underwent a ddMRI examination of the mandibular third molar region. ddMRI was acquired focusing on anatomic and inflammatory tissue characteristics, based on 2D proton-density-weighted image slabs, with and without fat suppression. Three trained observers independently evaluated all ddMRI datasets for image quality (very poor/poor/acceptable/good/optimal) and the anatomical conspicuity of the lingual nerve (visible/not visible). Statistical analysis included the frequency of possible lingual nerve visualization and the inter-observer agreement for that diagnostic task (kappa statistics). Results: Overall image quality ranged from acceptable to optimal (average good). The axial plane provided the most consistent visualization of the lingual nerve, which was identifiable in most cases (ranging from 85% to 95% of the cases among observers), although substantial inter-observer reproducibility was observed (kappa values ranging from 0.46 to 0.77, average 0.62). Conclusion: ddMRI enables lingual nerve visualization, predominantly in the axial plane. The wide range of inter-observer reproducibility and the lack of clinical validation must be further addressed in larger clinical trials.
- 15 May 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (6) , 636-644
Lingual nerve visualization with dental-dedicated MRI: feasibility and observer reproducibility
Objective: To evaluate the feasibility of lingual nerve visualization using dental-dedicated MRI (ddMRI), with emphasis on observer reproducibility in a patient series. Methods: Twenty consecutive healthy volunteers underwent a ddMRI examination of the mandibular third molar region. ddMRI was acquired focusing on anatomic and inflammatory tissue characteristics, based on 2D proton-density-weighted image slabs, with and without fat suppression. Three trained observers independently evaluated all ddMRI datasets for image quality (very poor/poor/acceptable/good/optimal) and the anatomical conspicuity of the lingual nerve (visible/not visible). Statistical analysis included the frequency of possible lingual nerve visualization and the inter-observer agreement for that diagnostic task (kappa statistics). Results: Overall image quality ranged from acceptable to optimal (average good). The axial plane provided the most consistent visualization of the lingual nerve, which was identifiable in most cases (ranging from 85% to 95% of the cases among observers), although substantial inter-observer reproducibility was observed (kappa values ranging from 0.46 to 0.77, average 0.62). Conclusion: ddMRI enables lingual nerve visualization, predominantly in the axial plane. The wide range of inter-observer reproducibility and the lack of clinical validation must be further addressed in larger clinical trials.
- 17 February 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
Comparison of dental-dedicated MRI to 2D radiographic images and cone beam CT in the assessment of lower third molars: a prospective study
Objectives: The aim of this study is to show that the use of 0.55 T MRI combined with a “dental-dedicated” coil produces images of sufficient diagnostic value to assess lower third molars (LTMs), that are not inferior to currently utilized dental-oriented radiographic images. Methods: Dental-dedicated MRI (ddMRI) scans were acquired using a Magnetom Free.Max 0.55 T scanner combined with a dedicated dental coil. Three observers assessed all images according to predefined criteria. Twenty percent of images were assessed twice by all observers. Kappa statistics were performed to assess intra- and inter-observer agreement as well as inter-modality agreement. Results: Dental-dedicated MRI was acquired on 67 patients (89 LTMs) in addition to initial radiographic exams (intraoral, panoramic, and/or CBCT). Inter-observer agreement for each modality ranged from low to perfect (intraoral/panoramic 0.480-0.942 [average 0.74], CBCT 0.218-1.000 [average 0.69], ddMRI −0.038 to 0.889 [average 0.53]). Intra-observer agreement ranged from low to perfect (intraoral/panoramic −0.047 to 1.000 [average 0.76], CBCT 0.389-1.000 [average 0.83], ddMRI −0.025 to 1.000 [average 0.61]). Inter-modality agreement ranged from low to high (intraoral/panoramic vs CBCT −0.078 to 0.743 [average 0.32], intraoral/panoramic vs ddMRI −0.078 to 0.752 [average 0.30], CBCT vs ddMRI 0.074-0.886 [average 0.49]). Conclusion: Dental-dedicated MRI could be a feasible diagnostic modality for LTM imaging. The modality shows promise for radiation-free imaging in the future. Advances in knowledge: This article is the first to demonstrate the use of ddMRI in LTM imaging and to compare the modality to existing modalities. The added value of this radiation-free modality can be beneficial to dentists and patients in the future.
- 17 February 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
Comparison of dental-dedicated MRI to 2D radiographic images and cone beam CT in the assessment of lower third molars: a prospective study
Objectives: The aim of this study is to show that the use of 0.55 T MRI combined with a “dental-dedicated” coil produces images of sufficient diagnostic value to assess lower third molars (LTMs), that are not inferior to currently utilized dental-oriented radiographic images. Methods: Dental-dedicated MRI (ddMRI) scans were acquired using a Magnetom Free.Max 0.55 T scanner combined with a dedicated dental coil. Three observers assessed all images according to predefined criteria. Twenty percent of images were assessed twice by all observers. Kappa statistics were performed to assess intra- and inter-observer agreement as well as inter-modality agreement. Results: Dental-dedicated MRI was acquired on 67 patients (89 LTMs) in addition to initial radiographic exams (intraoral, panoramic, and/or CBCT). Inter-observer agreement for each modality ranged from low to perfect (intraoral/panoramic 0.480-0.942 [average 0.74], CBCT 0.218-1.000 [average 0.69], ddMRI −0.038 to 0.889 [average 0.53]). Intra-observer agreement ranged from low to perfect (intraoral/panoramic −0.047 to 1.000 [average 0.76], CBCT 0.389-1.000 [average 0.83], ddMRI −0.025 to 1.000 [average 0.61]). Inter-modality agreement ranged from low to high (intraoral/panoramic vs CBCT −0.078 to 0.743 [average 0.32], intraoral/panoramic vs ddMRI −0.078 to 0.752 [average 0.30], CBCT vs ddMRI 0.074-0.886 [average 0.49]). Conclusion: Dental-dedicated MRI could be a feasible diagnostic modality for LTM imaging. The modality shows promise for radiation-free imaging in the future. Advances in knowledge: This article is the first to demonstrate the use of ddMRI in LTM imaging and to compare the modality to existing modalities. The added value of this radiation-free modality can be beneficial to dentists and patients in the future.
- Top Cited Papers
- 13 January 2026
- Published by Wiley in International Endodontic Journal
- Vol. 59 (5) , 776-787
Dental‐Dedicated MRI in the Assessment of Pulp Vitality and Apical Periodontitis: A Feasibility Study
Introduction: This feasibility study presents the diagnostic accuracy of a novel dental‐dedicated magnetic resonance imaging (ddMRI) system for assessing pulp vitality and diagnosing apical periodontitis (AP), as an adjunct to clinical assessment and cone beam CT (CBCT) imaging. Methods: Ten consecutive patients with possible endodontic problems were screened, and ultimately 18 teeth in nine patients (10 healthy teeth, five necrotic teeth with suspected AP and three necrotic or root canal treated teeth with no suspicion of AP) with a recent CBCT were included. The teeth were tested for vitality and clinical signs of AP. The CBCT volumes were assessed by three trained observers for signs of AP. The teeth were scanned using the Magnetom Free.Max Dental Edition ddMRI system (Siemens Healthineers, Forchheim, Germany), operating at 0.55 T with a seven‐channel dental‐dedicated surface coil. Six pulse sequences optimised for periapical diagnostics were applied, with a total scanning time of approximately 18 min per tooth. Images were assessed by three trained observers for anatomical structure conspicuity (root tip, periapical bone and lamina dura), pulp vitality determined by presence of signal and presence of AP determined by accumulation of fluid in the periapical area. The assessed pulp vitality status and presence of AP on ddMRI were compared to the clinical and radiological findings. Inter‐modality agreement was calculated using kappa statistics, and diagnostic accuracy was evaluated with consensus between clinical findings and CBCT imaging as the reference standard. Results: All anatomical structures were visible in all cases. ddMRI showed high diagnostic accuracy. For pulp vitality, the inter‐modality agreement kappa was 0.77 and accuracy was 0.88. For AP, the inter‐modality agreement kappa was 0.87 and accuracy was 0.94. Conclusions: ddMRI show promising results as a non‐ionising imaging modality for assessment of pulp vitality and diagnosis of AP. This feasibility study demonstrates the potential of ddMRI to provide accurate diagnostic support, laying a foundation for larger‐scale validation studies and clinical applications.
- 13 January 2026
- Published by Wiley in International Endodontic Journal
- Vol. 59 (5) , 776-787
Top Cited PapersDental‐Dedicated MRI in the Assessment of Pulp Vitality and Apical Periodontitis: A Feasibility Study
Introduction: This feasibility study presents the diagnostic accuracy of a novel dental‐dedicated magnetic resonance imaging (ddMRI) system for assessing pulp vitality and diagnosing apical periodontitis (AP), as an adjunct to clinical assessment and cone beam CT (CBCT) imaging. Methods: Ten consecutive patients with possible endodontic problems were screened, and ultimately 18 teeth in nine patients (10 healthy teeth, five necrotic teeth with suspected AP and three necrotic or root canal treated teeth with no suspicion of AP) with a recent CBCT were included. The teeth were tested for vitality and clinical signs of AP. The CBCT volumes were assessed by three trained observers for signs of AP. The teeth were scanned using the Magnetom Free.Max Dental Edition ddMRI system (Siemens Healthineers, Forchheim, Germany), operating at 0.55 T with a seven‐channel dental‐dedicated surface coil. Six pulse sequences optimised for periapical diagnostics were applied, with a total scanning time of approximately 18 min per tooth. Images were assessed by three trained observers for anatomical structure conspicuity (root tip, periapical bone and lamina dura), pulp vitality determined by presence of signal and presence of AP determined by accumulation of fluid in the periapical area. The assessed pulp vitality status and presence of AP on ddMRI were compared to the clinical and radiological findings. Inter‐modality agreement was calculated using kappa statistics, and diagnostic accuracy was evaluated with consensus between clinical findings and CBCT imaging as the reference standard. Results: All anatomical structures were visible in all cases. ddMRI showed high diagnostic accuracy. For pulp vitality, the inter‐modality agreement kappa was 0.77 and accuracy was 0.88. For AP, the inter‐modality agreement kappa was 0.87 and accuracy was 0.94. Conclusions: ddMRI show promising results as a non‐ionising imaging modality for assessment of pulp vitality and diagnosis of AP. This feasibility study demonstrates the potential of ddMRI to provide accurate diagnostic support, laying a foundation for larger‐scale validation studies and clinical applications.
- Open Access
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (1) , 73-82
Development and assessment of an ex vivo imaging protocol for dental-dedicated MRI systems: A pilot study
Liedke GS, et al. Imaging Sci Dent. 2026 Jan;56:e4. https://doi.org/10.5624/isd.20250228
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (1) , 73-82
Open AccessDevelopment and assessment of an ex vivo imaging protocol for dental-dedicated MRI systems: A pilot study
Liedke GS, et al. Imaging Sci Dent. 2026 Jan;56:e4. https://doi.org/10.5624/isd.20250228
- Open Access
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (1) , 36-44
Reliability of dental-dedicated magnetic resonance imaging for 2-dimensional orthodontic diagnosis: A pilot study of landmark identification
Srivastav S, et al. Imaging Sci Dent. 2025 Nov;55:e47. https://doi.org/10.5624/isd.20250201
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56 (1) , 36-44
Open AccessReliability of dental-dedicated magnetic resonance imaging for 2-dimensional orthodontic diagnosis: A pilot study of landmark identification
Srivastav S, et al. Imaging Sci Dent. 2025 Nov;55:e47. https://doi.org/10.5624/isd.20250201
- 18 December 2024
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 54 (2) , 132-139
Interference of titanium and zirconia implants on dental-dedicated MR image quality: ex vivo and in vivo assessment
Objectives: To assess the impact of titanium and zirconia implants on dental-dedicated MR image (ddMRI) quality ex vivo (magnetic field distortion [MFD]) and in vivo (artefacts). Methods: ddMR images were acquired (MAGNETOM Free.Max, 0.55 T, Siemens Healthineers AG, Forchheim, Germany) using a dental-dedicated coil (Rapid Biomedical, Rimpar, Germany). Ex vivo: three phantoms were manufactured: one agar-embedded titanium implant, one agar-embedded zirconia implant, and one control phantom (agar 1.5%). Field map analysis of images acquired at 0.55 T, 1.5 T, and 3.0 T (MAGNETOM Sola and MAGNETOM Lumina, respectively, Siemens Healthineers AG, Forchheim, Germany) was done to illustrate the extent and severity of MFD caused by the implants. In vivo (0.55 T only): a splint was designed to serve as an implant carrier, allowing diverse implant positions (0, 1, 2, or 5 implants). A volunteer was imaged using multiple pulse sequences. Three blinded observers scored the images twice for the presence, severity, and type of artefacts, illustrated by descriptive statistics and inter- and intra-observer reproducibility (kappa statistics). Results: Ex vivo: titanium produced more severe MFD than zirconia. MFD extent and amplitude increased with field strength (0.55 T < 1.5 T < 3.0 T). In vivo: titanium produced more artefacts than zirconia, generally as signal voids in tooth crowns close to implants. Inter- and intra-observer reproducibility ranged from 0.28 to 0.64 and 0.32 to 0.57, respectively. Conclusions: The prevalence of artefacts increased with magnetic field strength. Titanium generated larger MFD than zirconia. For both materials, artefacts were visible mainly in the crown area. Observer reproducibility needs improvement by dedicated ddMRI training.
- 18 December 2024
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 54 (2) , 132-139
Interference of titanium and zirconia implants on dental-dedicated MR image quality: ex vivo and in vivo assessment
Objectives: To assess the impact of titanium and zirconia implants on dental-dedicated MR image (ddMRI) quality ex vivo (magnetic field distortion [MFD]) and in vivo (artefacts). Methods: ddMR images were acquired (MAGNETOM Free.Max, 0.55 T, Siemens Healthineers AG, Forchheim, Germany) using a dental-dedicated coil (Rapid Biomedical, Rimpar, Germany). Ex vivo: three phantoms were manufactured: one agar-embedded titanium implant, one agar-embedded zirconia implant, and one control phantom (agar 1.5%). Field map analysis of images acquired at 0.55 T, 1.5 T, and 3.0 T (MAGNETOM Sola and MAGNETOM Lumina, respectively, Siemens Healthineers AG, Forchheim, Germany) was done to illustrate the extent and severity of MFD caused by the implants. In vivo (0.55 T only): a splint was designed to serve as an implant carrier, allowing diverse implant positions (0, 1, 2, or 5 implants). A volunteer was imaged using multiple pulse sequences. Three blinded observers scored the images twice for the presence, severity, and type of artefacts, illustrated by descriptive statistics and inter- and intra-observer reproducibility (kappa statistics). Results: Ex vivo: titanium produced more severe MFD than zirconia. MFD extent and amplitude increased with field strength (0.55 T < 1.5 T < 3.0 T). In vivo: titanium produced more artefacts than zirconia, generally as signal voids in tooth crowns close to implants. Inter- and intra-observer reproducibility ranged from 0.28 to 0.64 and 0.32 to 0.57, respectively. Conclusions: The prevalence of artefacts increased with magnetic field strength. Titanium generated larger MFD than zirconia. For both materials, artefacts were visible mainly in the crown area. Observer reproducibility needs improvement by dedicated ddMRI training.
- 1 August 2024
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 53 (8) , 527-534
Scout images acquired prior to cone beam CT acquisitions: reproducibility of findings and added diagnostic information
Objectives: The aim of the present study was to assess the reproducibility of findings in cone beam CT (CBCT) scout images. Furthermore, the study aimed to assess whether a scout image shows pathology not seen within the CBCT volume (ie, added diagnostic information) and therefore must be assessed on the same terms as the full volume. Methods: Using a retrospective design, 233 CBCT reports and scout images were assessed. Kappa statistics and percentage of accordance were used to evaluate intra- and inter-observer reproducibility as well as agreement between scout and CBCT report. Results: Intra- and inter-observer reproducibility was overall low (kappa ranging from −0.008 to 1.000). Agreement between findings reported in the CBCT and scout was also low. One hundred fourteen impacted teeth, one apical periodontitis, and two sinus conditions seen in the scout image were not registered in the full volume report due to the extended size of the scout image. Conclusions: Reproducibility of findings in scout images compared to CBCT volumes was low, and the scout showed very little additional diagnostic information. Advances in knowledge: This study shows that although the reproducibility of viewing scout images is low, rare findings can go undetected if the scout is not assessed. Legislation regarding interpretation of scout images needs to be discussed.
- 1 August 2024
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 53 (8) , 527-534
Scout images acquired prior to cone beam CT acquisitions: reproducibility of findings and added diagnostic information
Objectives: The aim of the present study was to assess the reproducibility of findings in cone beam CT (CBCT) scout images. Furthermore, the study aimed to assess whether a scout image shows pathology not seen within the CBCT volume (ie, added diagnostic information) and therefore must be assessed on the same terms as the full volume. Methods: Using a retrospective design, 233 CBCT reports and scout images were assessed. Kappa statistics and percentage of accordance were used to evaluate intra- and inter-observer reproducibility as well as agreement between scout and CBCT report. Results: Intra- and inter-observer reproducibility was overall low (kappa ranging from −0.008 to 1.000). Agreement between findings reported in the CBCT and scout was also low. One hundred fourteen impacted teeth, one apical periodontitis, and two sinus conditions seen in the scout image were not registered in the full volume report due to the extended size of the scout image. Conclusions: Reproducibility of findings in scout images compared to CBCT volumes was low, and the scout showed very little additional diagnostic information. Advances in knowledge: This study shows that although the reproducibility of viewing scout images is low, rare findings can go undetected if the scout is not assessed. Legislation regarding interpretation of scout images needs to be discussed.