FBFaiza Benabdallah
Faiza Benabdallah
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Faiza Benabdallah has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hind Albalawi
Department of Physics, College of Sciences, Princess Nourah bint Abdulrahman University (PNU), P.O. Box 84428, Riyadh 11671, Saudi Arabia
2 shared publications - Kaouther Ghachem
Department of Industrial and Systems Engineering, College of Engineering, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
2 shared publications - Lioua Kolsi
Department of Mechanical Engineering College of Engineering University of Ha'il Ha'il City Saudi Arabia
2 shared publications - Akbar Hussain
Department of Chemistry, Quaid-i-Azam University, Islamabad, Pakistan
1 shared publication - Asadullah Dawood
Government College University
1 shared publication - Ayesha Kanwal
Department of Chemistry, Quaid-i-Azam University, Islamabad, Pakistan
1 shared publication
Latest Publications
- 22 January 2025
- Published by Springer Nature in Ionics
- Vol. 31 (3) , 2439-2456
Sol–gel synthesis of magnesium-doped lithium cobalt, nickel, and zinc olivine phosphates, and their electrochemical application
- 22 January 2025
- Published by Springer Nature in Ionics
- Vol. 31 (3) , 2439-2456
Sol–gel synthesis of magnesium-doped lithium cobalt, nickel, and zinc olivine phosphates, and their electrochemical application
- Open Access
- 1 January 2024
- Published by Walter de Gruyter GmbH in Open Physics
- Vol. 22 (1)
Single-channel cooling system design by using perforated porous insert and modeling with POD for double conductive panel
In this study, a single cooling channel system is suggested for conductive double panel systems. The cooling channel for the vertical component uses perforated porous insert (PP-I) and porous insert (P-I), while cylinders are used in the PP-I case. The permeability of the porous channel (Da between and ), size of the cylinders (Rc between 0 and 0.25), and location of the PP plate (Yp between 1 and 4.5) are all taken into account when calculating the effectiveness of the cooling system using finite element method. It is found that PP-I can effectively control the vortex size and enhance cooling performance, particularly for vertical plate. Nusselt number is enhanced in the absence of cylinders in the vertical channel by 92% as contrasted to 51% in the presence of cylinders. When cylinders are used for the vertical channel, the temperature drop of is computed. The flow field noticeably changes when the permeability of the P-I and PP-I is altered. The equivalent temperature increases for P-I and PP-I with setups at and are and , respectively. The performance of cooling for the vertical plate is influenced favorably by the higher values of the porous plate’s vertical placement. By moving the porous object, it is possible to reduce the temperature by . For panel surface temperature, a proper orthogonal decomposition (POD)-based reconstruction model with 12 POD modes is used. The POD-based model accurately captures the effects of utilizing P-I and PP-I on the panel temperature.- 1 January 2024
- Published by Walter de Gruyter GmbH in Open Physics
- Vol. 22 (1)
Open AccessSingle-channel cooling system design by using perforated porous insert and modeling with POD for double conductive panel
In this study, a single cooling channel system is suggested for conductive double panel systems. The cooling channel for the vertical component uses perforated porous insert (PP-I) and porous insert (P-I), while cylinders are used in the PP-I case. The permeability of the porous channel (Da between and ), size of the cylinders (Rc between 0 and 0.25), and location of the PP plate (Yp between 1 and 4.5) are all taken into account when calculating the effectiveness of the cooling system using finite element method. It is found that PP-I can effectively control the vortex size and enhance cooling performance, particularly for vertical plate. Nusselt number is enhanced in the absence of cylinders in the vertical channel by 92% as contrasted to 51% in the presence of cylinders. When cylinders are used for the vertical channel, the temperature drop of is computed. The flow field noticeably changes when the permeability of the P-I and PP-I is altered. The equivalent temperature increases for P-I and PP-I with setups at and are and , respectively. The performance of cooling for the vertical plate is influenced favorably by the higher values of the porous plate’s vertical placement. By moving the porous object, it is possible to reduce the temperature by . For panel surface temperature, a proper orthogonal decomposition (POD)-based reconstruction model with 12 POD modes is used. The POD-based model accurately captures the effects of utilizing P-I and PP-I on the panel temperature.