L. Ricon
Research Subjects
L. Ricon has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
E. Vicente
1 shared publication- Eduardo Lage
Departamento de Tecnología Electrónica y de las Comunicaciones, Universidad Autónoma de Madrid; Instituto de Investigación Sanitaria de la Fundación Jiménez Díaz, Spain
1 shared publication J.J. Vaquero
Unidad de Medicina y Cirugia Exp., Hospital GU Gregorio Maranon, Madrid, Spain
1 shared publication- Manuel Desco
Universidad Carlos III de Madrid
1 shared publication - Monica Abella
Universidad Carlos III de Madrid
1 shared publication
Latest Publications
- 21 March 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5 (10823654) , 2885-2889
rPET Detectors Design and Data Processing
Small animal PET systems based on rotating planar detectors posses some interesting advantages for high sensitivity, high resolution imaging. We have designed the rPET detectors based on MLS crystals assembled on a 30times30 matrix optically coupled to a flat-panel PS-PMT. Weighted position readout circuits pre-process the 64 signals from the 8times8 anodes matrix, which are digitized using a charge-integrating converter. The amplification electronics, including the trigger output for coincidence detection, and the high voltage supply are integrated in a three PCBs stack that forms the base attached to the back of the PMT. The whole assembly is enclosed in a light tight, lead (Pb) shielded aluminum box. The detectors are mounted on a rotating gantry with more than 180 degrees rotation span. The digitized events are screened and histogramed, and a modified center of gravity algorithm removes from the position calculation those signals with poor signal to noise ratio. Apparent mean crystal size on the 511 keV field-flood images is 0.6 mm, mean peak-to-valley ratio is better than 8, and intrinsic resolution is 1.5 mm at the central row, with the energy window wide open. Sensitivity (CPS) for a pair of these detectors set in coincidence at 160 mm distance is 1%
- 21 March 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5 (10823654) , 2885-2889
rPET Detectors Design and Data Processing
Small animal PET systems based on rotating planar detectors posses some interesting advantages for high sensitivity, high resolution imaging. We have designed the rPET detectors based on MLS crystals assembled on a 30times30 matrix optically coupled to a flat-panel PS-PMT. Weighted position readout circuits pre-process the 64 signals from the 8times8 anodes matrix, which are digitized using a charge-integrating converter. The amplification electronics, including the trigger output for coincidence detection, and the high voltage supply are integrated in a three PCBs stack that forms the base attached to the back of the PMT. The whole assembly is enclosed in a light tight, lead (Pb) shielded aluminum box. The detectors are mounted on a rotating gantry with more than 180 degrees rotation span. The digitized events are screened and histogramed, and a modified center of gravity algorithm removes from the position calculation those signals with poor signal to noise ratio. Apparent mean crystal size on the 511 keV field-flood images is 0.6 mm, mean peak-to-valley ratio is better than 8, and intrinsic resolution is 1.5 mm at the central row, with the energy window wide open. Sensitivity (CPS) for a pair of these detectors set in coincidence at 160 mm distance is 1%