Johanna Tratz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Johanna Tratz has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Manfred Wilhelm
Institute for Chemical Technology and Polymer Chemistry Karlsruhe Institute of Technology (KIT) Karlsruhe Germany
3 shared publications - Marianne Gaborieau
Institute of Chemical Technology and Polymer Chemistry Karlsruhe Institute of Technology (KIT) Engesserstraße 18 76131 Karlsruhe Germany
3 shared publications - Markus Matz
Institute of Chemical Technology and Polymer Chemistry Karlsruhe Institute of Technology (KIT) Engesserstraße 18 76131 Karlsruhe Germany
3 shared publications Michael Pollard
Institute of Chemical Technology and Polymer Chemistry Karlsruhe Institute of Technology (KIT) Engesserstraße 18 76131 Karlsruhe Germany
2 shared publicationsCarlo Botha
Institute for Chemical Technology and Polymer Chemistry, Karlsruhe Institute of Technology (KIT), Engesserstraße 18, Karlsruhe 76131, Germany
1 shared publication- Michael Pollard
Institute of Chemical Technology and Polymer Chemistry Karlsruhe Institute of Technology (KIT) Engesserstraße 18 76131 Karlsruhe Germany
1 shared publication
Latest Publications
- Open Access
- 18 May 2025
- Published by Wiley in Macromolecular Rapid Communications
- Vol. 46 (23) , e2500239
Online Coupling of 80 MHz Benchtop 2D‐COSY NMR to HPLC
HPLC is coupled online for the first time to 2D‐NMR on a benchtop NMR spectrometer. The potential is demonstrated at 80 MHz with COSY ( 1 H‐ 1 H COrrelation SpectroscopY) for a mixture of methyl and propyl parabens, additives commonly used in cosmetics. To lessen the impact of short residence time in the NMR flow cell, a repetition delay reduction combined with non‐uniform sampling (NUS) allows decreasing the COSY experiment duration from 1 h to 2 min. The HPLC‐benchtop 2D‐NMR online coupling is established for the first time, using three different modes: stop‐flow (with short stops at the analyte peaks and in the baseline), slow‐flow (with a lower, constant flow rate over the whole elution range of analytes) and steady‐flow (with a constant flow rate throughout the experiment). The HPLC‐benchtop 2D‐NMR online coupling allows the successful separation and characterization of methyl and propyl parabens at low field. This provides more in‐depth chemical information on separated analytes than HPLC‐benchtop 1D‐NMR, with a smaller footprint, reduced experimental complexity and at lower costs than HPLC‐high‐field 2D‐NMR. It opens the way to other 2D‐NMR experiments and the characterization of a wider range of analytes such as oligomers, small molar mass additives, or polymers.
- 18 May 2025
- Published by Wiley in Macromolecular Rapid Communications
- Vol. 46 (23) , e2500239
Open AccessOnline Coupling of 80 MHz Benchtop 2D‐COSY NMR to HPLC
HPLC is coupled online for the first time to 2D‐NMR on a benchtop NMR spectrometer. The potential is demonstrated at 80 MHz with COSY ( 1 H‐ 1 H COrrelation SpectroscopY) for a mixture of methyl and propyl parabens, additives commonly used in cosmetics. To lessen the impact of short residence time in the NMR flow cell, a repetition delay reduction combined with non‐uniform sampling (NUS) allows decreasing the COSY experiment duration from 1 h to 2 min. The HPLC‐benchtop 2D‐NMR online coupling is established for the first time, using three different modes: stop‐flow (with short stops at the analyte peaks and in the baseline), slow‐flow (with a lower, constant flow rate over the whole elution range of analytes) and steady‐flow (with a constant flow rate throughout the experiment). The HPLC‐benchtop 2D‐NMR online coupling allows the successful separation and characterization of methyl and propyl parabens at low field. This provides more in‐depth chemical information on separated analytes than HPLC‐benchtop 1D‐NMR, with a smaller footprint, reduced experimental complexity and at lower costs than HPLC‐high‐field 2D‐NMR. It opens the way to other 2D‐NMR experiments and the characterization of a wider range of analytes such as oligomers, small molar mass additives, or polymers.
- 20 September 2024
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 128 (39) , 9512-9524
Enhancing Sensitivity in the Hyphenation of High-Performance Liquid Chromatography to Benchtop Nuclear Magnetic Resonance Spectroscopy at Isocratic and Onflow Conditions
The onflow hyphenation of high-performance liquid chromatography (HPLC) in adsorption mode with a benchtop 1H nuclear magnetic resonance (NMR) spectrometer is described for the first time. Protonated solvents and isocratic conditions are used. The sensitivity was increased by choosing suitable NMR acquisition parameter as well as optimizing injection parameters and postacquisition data processing methods. With optimized conditions, the limit of detection (LOD) and the limit of quantification (LOQ) were LOD = 0.010 g L–1 and LOQ = 0.031 g L–1 for the methoxy 1H of methyl paraben at 4.07 ppm, LOD = 0.038 g L–1 and LOQ = 0.134 g L–1 for the aromatic 1H of pentyl paraben between 7.00 and 8.50 ppm. These are expressed in injection concentration and are comparable to existing HPLC hyphenation with high-field NMR spectrometers. The analysis of a 2 g L–1 paraben mixture, far below the legal limits for usage in cosmetics, illustrates the applicability of the method. Taking advantage of the spectral resolution, chromatographically overlapping peaks are resolved using analyte-specific NMR elution traces. A methodology is detailed to facilitate the transfer of the optimized method to other (analyte) systems.
- 20 September 2024
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 128 (39) , 9512-9524
Enhancing Sensitivity in the Hyphenation of High-Performance Liquid Chromatography to Benchtop Nuclear Magnetic Resonance Spectroscopy at Isocratic and Onflow Conditions
The onflow hyphenation of high-performance liquid chromatography (HPLC) in adsorption mode with a benchtop 1H nuclear magnetic resonance (NMR) spectrometer is described for the first time. Protonated solvents and isocratic conditions are used. The sensitivity was increased by choosing suitable NMR acquisition parameter as well as optimizing injection parameters and postacquisition data processing methods. With optimized conditions, the limit of detection (LOD) and the limit of quantification (LOQ) were LOD = 0.010 g L–1 and LOQ = 0.031 g L–1 for the methoxy 1H of methyl paraben at 4.07 ppm, LOD = 0.038 g L–1 and LOQ = 0.134 g L–1 for the aromatic 1H of pentyl paraben between 7.00 and 8.50 ppm. These are expressed in injection concentration and are comparable to existing HPLC hyphenation with high-field NMR spectrometers. The analysis of a 2 g L–1 paraben mixture, far below the legal limits for usage in cosmetics, illustrates the applicability of the method. Taking advantage of the spectral resolution, chromatographically overlapping peaks are resolved using analyte-specific NMR elution traces. A methodology is detailed to facilitate the transfer of the optimized method to other (analyte) systems.
- Open Access
- 6 August 2024
- Published by Wiley in Macromolecular Rapid Communications
- Vol. 45 (24) , e2400512
Potential of Benchtop NMR for the Determination of Polymer Molar Masses, Molar Mass Distributions, and Chemical Composition Profiles by Means of Diffusion‐Ordered Spectroscopy, DOSY
The determination of molar masses and their distributions is crucial in polymer synthesis and design. This work presents the current performance and limitations of diffusion‐ordered spectroscopy (DOSY) on a low‐field (benchtop) NMR spectrometer (at 90 MHz) as an alternative to size exclusion chromatography (SEC) for determining diffusion coefficient distributions (DCDs) and molar mass distributions (MMDs). After optimization for narrowly distributed homopolymers, MMDs obtained with inverse Laplace transformation (ILT) and log‐normal distribution are compared with average molar masses obtained with mono‐ and bi‐exponential fits, as well as MMDs obtained from SEC. This approach enables ILT to determine DCDs and MMDs even for bimodal homopolymers with fully spectrally overlapping signals and block copolymers with various chemical compositions, for which chemical composition profiles are determined. The feasibility of low‐field diffusion NMR with samples dissolved in non‐deuterated solvents is further demonstrated and methods for solvent suppression are discussed.
- 6 August 2024
- Published by Wiley in Macromolecular Rapid Communications
- Vol. 45 (24) , e2400512
Open AccessPotential of Benchtop NMR for the Determination of Polymer Molar Masses, Molar Mass Distributions, and Chemical Composition Profiles by Means of Diffusion‐Ordered Spectroscopy, DOSY
The determination of molar masses and their distributions is crucial in polymer synthesis and design. This work presents the current performance and limitations of diffusion‐ordered spectroscopy (DOSY) on a low‐field (benchtop) NMR spectrometer (at 90 MHz) as an alternative to size exclusion chromatography (SEC) for determining diffusion coefficient distributions (DCDs) and molar mass distributions (MMDs). After optimization for narrowly distributed homopolymers, MMDs obtained with inverse Laplace transformation (ILT) and log‐normal distribution are compared with average molar masses obtained with mono‐ and bi‐exponential fits, as well as MMDs obtained from SEC. This approach enables ILT to determine DCDs and MMDs even for bimodal homopolymers with fully spectrally overlapping signals and block copolymers with various chemical compositions, for which chemical composition profiles are determined. The feasibility of low‐field diffusion NMR with samples dissolved in non‐deuterated solvents is further demonstrated and methods for solvent suppression are discussed.