Michael Pollard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael Pollard has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Robert Lee Chin
University of New South Wales Sydney NSW Australia
2 shared publications - Ziv Hameiri
School of Photovoltaic and Renewable Energy Engineering University of New South Wales Sydney New South Wales Australia
2 shared publications - Johanna Tratz
Institute of Chemical Technology and Polymer Chemistry Karlsruhe Institute of Technology (KIT) Engesserstraße 18 76131 Karlsruhe Germany
1 shared publication - Manfred Wilhelm
Institute for Chemical Technology and Polymer Chemistry Karlsruhe Institute of Technology (KIT) Karlsruhe Germany
1 shared publication - Marianne Gaborieau
Institute of Chemical Technology and Polymer Chemistry Karlsruhe Institute of Technology (KIT) Engesserstraße 18 76131 Karlsruhe Germany
1 shared publication - Markus Matz
Institute of Chemical Technology and Polymer Chemistry Karlsruhe Institute of Technology (KIT) Engesserstraße 18 76131 Karlsruhe Germany
1 shared publication
Latest Publications
- Open Access
- 6 August 2024
- Published by Wiley in Macromolecular Rapid Communications
- Vol. 45 (24) , e2400512
Potential of Benchtop NMR for the Determination of Polymer Molar Masses, Molar Mass Distributions, and Chemical Composition Profiles by Means of Diffusion‐Ordered Spectroscopy, DOSY
The determination of molar masses and their distributions is crucial in polymer synthesis and design. This work presents the current performance and limitations of diffusion‐ordered spectroscopy (DOSY) on a low‐field (benchtop) NMR spectrometer (at 90 MHz) as an alternative to size exclusion chromatography (SEC) for determining diffusion coefficient distributions (DCDs) and molar mass distributions (MMDs). After optimization for narrowly distributed homopolymers, MMDs obtained with inverse Laplace transformation (ILT) and log‐normal distribution are compared with average molar masses obtained with mono‐ and bi‐exponential fits, as well as MMDs obtained from SEC. This approach enables ILT to determine DCDs and MMDs even for bimodal homopolymers with fully spectrally overlapping signals and block copolymers with various chemical compositions, for which chemical composition profiles are determined. The feasibility of low‐field diffusion NMR with samples dissolved in non‐deuterated solvents is further demonstrated and methods for solvent suppression are discussed.
- 6 August 2024
- Published by Wiley in Macromolecular Rapid Communications
- Vol. 45 (24) , e2400512
Open AccessPotential of Benchtop NMR for the Determination of Polymer Molar Masses, Molar Mass Distributions, and Chemical Composition Profiles by Means of Diffusion‐Ordered Spectroscopy, DOSY
The determination of molar masses and their distributions is crucial in polymer synthesis and design. This work presents the current performance and limitations of diffusion‐ordered spectroscopy (DOSY) on a low‐field (benchtop) NMR spectrometer (at 90 MHz) as an alternative to size exclusion chromatography (SEC) for determining diffusion coefficient distributions (DCDs) and molar mass distributions (MMDs). After optimization for narrowly distributed homopolymers, MMDs obtained with inverse Laplace transformation (ILT) and log‐normal distribution are compared with average molar masses obtained with mono‐ and bi‐exponential fits, as well as MMDs obtained from SEC. This approach enables ILT to determine DCDs and MMDs even for bimodal homopolymers with fully spectrally overlapping signals and block copolymers with various chemical compositions, for which chemical composition profiles are determined. The feasibility of low‐field diffusion NMR with samples dissolved in non‐deuterated solvents is further demonstrated and methods for solvent suppression are discussed.
- 10 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 12 (3) , 778-786
Bulk Lifetime and Doping in Crystalline Silicon via Two-Photon Absorption Time-Resolved Photoluminescence Decay
Bulk lifetime ( $\tau _{\text{bulk}}$ ) and bulk doping ( $N_{\text{dop}}$ ) are critical material parameters influencing solar cell performance. The ability to probe spatial variations in $\tau _{\text{bulk}}$ and $N_{\text{dop}}$ in ingots, prior to wafer cutting and further processing, would be beneficial to improving the yield and reducing the cost of silicon solar cells. This study demonstrates the capability of the two-photon time-resolved photoluminescence decay method to determine both $\tau _{\text{bulk}}$ and $N_{\text{dop}}$ in thick crystalline silicon samples. The use of two photon excitation enables a more uniform carrier generation profile compared to conventional single-photon excitation, making measurements less sensitive to surface effects. The method is verified using an unpassivated $n$ -type Czochralski silicon disk and found to be in good agreement with the results obtained from the photoluminescence ratio imaging method.
- 10 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 12 (3) , 778-786
Bulk Lifetime and Doping in Crystalline Silicon via Two-Photon Absorption Time-Resolved Photoluminescence Decay
Bulk lifetime ( $\tau _{\text{bulk}}$ ) and bulk doping ( $N_{\text{dop}}$ ) are critical material parameters influencing solar cell performance. The ability to probe spatial variations in $\tau _{\text{bulk}}$ and $N_{\text{dop}}$ in ingots, prior to wafer cutting and further processing, would be beneficial to improving the yield and reducing the cost of silicon solar cells. This study demonstrates the capability of the two-photon time-resolved photoluminescence decay method to determine both $\tau _{\text{bulk}}$ and $N_{\text{dop}}$ in thick crystalline silicon samples. The use of two photon excitation enables a more uniform carrier generation profile compared to conventional single-photon excitation, making measurements less sensitive to surface effects. The method is verified using an unpassivated $n$ -type Czochralski silicon disk and found to be in good agreement with the results obtained from the photoluminescence ratio imaging method.