Federico Fuin
Federico Fuin has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Cecconi
Laboratory of Environmental Engineering, Department of Civil Engineering and Computer Science Engineering, University of Rome Tor Vergata, Via del Politecnico 1, 00133 Rome, Italy
1 shared publication - Alessandro Oldani
Eni, Via G. Fauser 4, 28100 Novara, Italy
1 shared publication - Antonella Vecchio
Department for the Geological Survey of Italy, ISPRA (Istituto Superiore per la Protezione e la Ricerca Ambientale), Italian Institute for Environmental Protection and Research, 00144 Rome, Italy
1 shared publication - Camilla Lanari
Eni Rewind, Piazza M. Boldrini 1, 20097 San Donato Milanese, Italy
1 shared publication Davide Casabianca
Copernico Milano srl, Cinisello Balsamo, Italy
1 shared publication- Donatella Giacopetti
UNEM (Energy Union for Mobility), Piazzale L. Sturzo 31, 00144 Rome, Italy
1 shared publication
Latest Publications
- Open Access
- 26 April 2025
- Published by MDPI AG in Environments
- Vol. 12 (5) , 141
Field Comparison of Active and Passive Soil Gas Sampling Techniques for VOC Monitoring at Contaminated Sites
This study presented a comprehensive comparison of soil gas sampling methodologies to monitor volatile organic compounds (VOCs) at two industrial sites in northern Italy. Utilizing active sampling techniques, such as stainless-steel canisters, vacuum bottles, and sorbent tubes, alongside passive methods like low-density polyethylene (PE) membranes, sorbent pens, and Waterloo Membrane Samplers (WMS), the research examines their effectiveness under varied environmental conditions. Five field campaigns were conducted in two areas of the industrial sites characterized by BTEX and chlorinated solvent contamination. The results highlighted that active sampling, while expensive, provides real-time, high-resolution VOC concentration data, often outperforming passive methods for heavier compounds (e.g., hexachlorobutadiene). However, using the active systems in certain campaigns, challenges such as high soil humidity or atmospheric air infiltration were observed, resulting in an underestimation of the soil gas concentrations. Passive sampling systems demonstrated cost-effective, efficient alternatives, offering consistent spatial and temporal coverage. These methods showed alignment with active techniques for lighter compounds (e.g., TCE and BTEX) but faced limitations in sorbent saturation and equilibrium time for heavier VOCs (e.g., hexachlorobutadiene), requiring adjustments in exposure duration to enhance accuracy. PE samplers provided results comparable to active methods, especially for BTEX and TCE, while WMS and sorbent pens exhibited lower sensitivity for certain analytes. This underscores the importance of optimizing sampler configurations and deployment strategies. The findings emphasize the value of integrating active and passive approaches to achieve robust VOC assessments in heterogeneous subsurface environments.
- 26 April 2025
- Published by MDPI AG in Environments
- Vol. 12 (5) , 141
Open AccessField Comparison of Active and Passive Soil Gas Sampling Techniques for VOC Monitoring at Contaminated Sites
This study presented a comprehensive comparison of soil gas sampling methodologies to monitor volatile organic compounds (VOCs) at two industrial sites in northern Italy. Utilizing active sampling techniques, such as stainless-steel canisters, vacuum bottles, and sorbent tubes, alongside passive methods like low-density polyethylene (PE) membranes, sorbent pens, and Waterloo Membrane Samplers (WMS), the research examines their effectiveness under varied environmental conditions. Five field campaigns were conducted in two areas of the industrial sites characterized by BTEX and chlorinated solvent contamination. The results highlighted that active sampling, while expensive, provides real-time, high-resolution VOC concentration data, often outperforming passive methods for heavier compounds (e.g., hexachlorobutadiene). However, using the active systems in certain campaigns, challenges such as high soil humidity or atmospheric air infiltration were observed, resulting in an underestimation of the soil gas concentrations. Passive sampling systems demonstrated cost-effective, efficient alternatives, offering consistent spatial and temporal coverage. These methods showed alignment with active techniques for lighter compounds (e.g., TCE and BTEX) but faced limitations in sorbent saturation and equilibrium time for heavier VOCs (e.g., hexachlorobutadiene), requiring adjustments in exposure duration to enhance accuracy. PE samplers provided results comparable to active methods, especially for BTEX and TCE, while WMS and sorbent pens exhibited lower sensitivity for certain analytes. This underscores the importance of optimizing sampler configurations and deployment strategies. The findings emphasize the value of integrating active and passive approaches to achieve robust VOC assessments in heterogeneous subsurface environments.
- 1 November 2024
- Published by Oxford University Press (OUP) in Integrated Environmental Assessment and Management
- Vol. 20 (6) , 2023-2032
Short-term temporal variability of volatile contaminant concentrations in soil gas related to soil–atmosphere interface dynamics: Two case studies in the Veneto region (Italy)
The study of the variability of soil gas concentrations is crucial for defining effective monitoring and remediation strategies and for the risk assessment related to the emission of vapors from the subsurface. The traditional soil gas monitoring strategy consists of seasonal surveys based on short-time-averaged sampling. Soil gas monitoring results are often used to assess the risk associated with the emission of volatile contaminants from the subsurface, using models mainly based on molecular diffusion and therefore assuming continuous emission from the soil. At two contaminated sites located in the Veneto region (Italy), continuous monitoring using a photoionization detector, pressure gauges, and an ultrasonic anemometer was used to relate soil gas variability to surface and subsurface physical parameters. At both sites a cyclic diurnal variation of volatile organic compounds concentration in soil gas was observed, correlated with the variation of several meteorological parameters and in particular with the variation of the differential pressure between soil and atmosphere and the buoyancy vertical flux. These findings question the reliability of the conventional methodology employed in the collection and assessment of soil gas data. Integr Environ Assess Manag 2024;20:2023–2032. © 2024 SETAC Key Points Continuous monitoring at the two study sites showed that the cyclic variation of VOC concentration in soil gas correlated with the variation of differential pressure and buoyancy vertical flux. As evidenced by the differential pressure measurements conducted in this study, there is an alternation of nonemission phases, and phases in which the soil gas emission from soil to atmosphere may be enhanced due to pressure-driven advective fluxes. The findings raise questions about the reliability of the conventional methodology employed in the collection and assessment of soil gas data.
- 1 November 2024
- Published by Oxford University Press (OUP) in Integrated Environmental Assessment and Management
- Vol. 20 (6) , 2023-2032
Short-term temporal variability of volatile contaminant concentrations in soil gas related to soil–atmosphere interface dynamics: Two case studies in the Veneto region (Italy)
The study of the variability of soil gas concentrations is crucial for defining effective monitoring and remediation strategies and for the risk assessment related to the emission of vapors from the subsurface. The traditional soil gas monitoring strategy consists of seasonal surveys based on short-time-averaged sampling. Soil gas monitoring results are often used to assess the risk associated with the emission of volatile contaminants from the subsurface, using models mainly based on molecular diffusion and therefore assuming continuous emission from the soil. At two contaminated sites located in the Veneto region (Italy), continuous monitoring using a photoionization detector, pressure gauges, and an ultrasonic anemometer was used to relate soil gas variability to surface and subsurface physical parameters. At both sites a cyclic diurnal variation of volatile organic compounds concentration in soil gas was observed, correlated with the variation of several meteorological parameters and in particular with the variation of the differential pressure between soil and atmosphere and the buoyancy vertical flux. These findings question the reliability of the conventional methodology employed in the collection and assessment of soil gas data. Integr Environ Assess Manag 2024;20:2023–2032. © 2024 SETAC Key Points Continuous monitoring at the two study sites showed that the cyclic variation of VOC concentration in soil gas correlated with the variation of differential pressure and buoyancy vertical flux. As evidenced by the differential pressure measurements conducted in this study, there is an alternation of nonemission phases, and phases in which the soil gas emission from soil to atmosphere may be enhanced due to pressure-driven advective fluxes. The findings raise questions about the reliability of the conventional methodology employed in the collection and assessment of soil gas data.