XZXiang Zhang

Xiang Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiang Zhang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Yonggang Wang

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui, China

    4 shared publications
  • Huandong Huang

    State Key Laboratory of Particle Detection and Electronics (Hefei), China

    2 shared publications
  • Lingyun Li

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics (Hefei), University of Science and Technology of China, Hefei, Anhui, China

    1 shared publication
  • Mingchen Wang

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics (Hefei), University of Science and Technology of China, Hefei, Anhui, China

    1 shared publication
  • Xiaoguang Kong

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics (Hefei), University of Science and Technology of China, Hefei, Anhui, China

    1 shared publication
  • Xinchi Xu

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, China

    1 shared publication

Latest Publications

  • An FPGA-based Scalable Coincidence Processor for High Count-rate PET Systems

    by Huandong Huang, Yonggang Wang, Xiang Zhang

    A hardware-based coincidence processor (CP) is essential for a high count-rate positron emission tomography (PET) with multiple detectors. This paper presents a scalable design and implementation of such a CP based on a Xilinx UltraScale Field Programmable Gate Array (FPGA). By dividing the detector ring into six sectors, a distributed coincidence processing with 15 parallel coincidence selectors is implemented to balance between processor throughput and hardware resource consumption. To simplify the selector structure, detection events from the detector modules within the same sector must be sorted before entering the processor. Since all the selectors and sorters are adjustable, the system is manually configurable in terms of field-of-view (FOV) and the number of inputs. In the current design, each sector sorter can handle up to 8 detector modules, therefore the CP can be configured to connect a maximum of 48 detector modules. The functionality and performance of the proposed CP are evaluated with both simulation and experimental data. The test results show that the system throughput can reach 750 Mcps, meanwhile the resource consumption is less than 20% of the chip resources. The configurability and scalability of the CP enable it to meet the needs of PETs with different scales.

  • A Low-Power 8×8 SiPM Readout ASIC With Row-Column Summing Structure for Compact TOF-PET Detectors

    by Xinchi Xu, Yonggang Wang, Xiang Zhang, Huandong Huang, Yonghang Zhou, Zhengqi Song

    A new low-power 64-channel Front-End application-specific integrated circuit (ASIC) for the readout of $8\times 8$ Silicon photomultiplier (SiPM) Arrays (FESA) with a row-column summing structure is proposed for flexibly building a compact and cost-effective time-of-flight (TOF) positron emission tomography (PET) system. The inputs from the SiPM array are picked up individually and row-column summed to reduce the number of measurement circuits and overall power consumption. An energy-to-time conversion circuit based on the delayed linear discharge method is proposed with high linearity and enhanced small-signal measurement ability, which allows FESA to use a fully time-based readout strategy so that a simple and robust interface for system-level integration is provided. Fabricated in 180 nm CMOS technology, FESA has been evaluated with an intrinsic timing jitter of 11.8 ps, a dynamic energy measurement range of 44 dB, a power consumption of 2.39 mW per channel, and an event rate of 4 MS/s. With an $8\times 8$ Hamamatsu S13361-3050 SiPM array 1:1 coupled to an $8\times 8$ lutetium yttrium oxyorthosilicate (LYSO) crystal array, the FESA-based detector exhibits a coincidence time resolution (CTR) of 237 ps FWHM and an energy resolution of 12.6%. The measured flood image with an $8\times 8$ SiPM array 1:9 coupled to a $24\times 24$ LYSO crystal array demonstrates the ability of FESA to decode a crystal size of 1 mm. The test results show that FESA is a promising candidate for the future construction of high-performance and high-integration TOF-PET systems.

  • Study of Delay Instabilities in Xilinx FPGA-Embedded Multigigabit Transceivers for Clock Distribution and Synchronization

    by Lingyun Li, Yonggang Wang, Yang Hu, Xiang Zhang

    Multi-gigabit transceivers (MGTs) of Xilinx field-programmable gate arrays (FPGAs) have been widely investigated for the implementation of clock distribution and synchronization systems in physics experiments. Often, the proposed solutions are based on the clock signal recovered from the serial stream. However, since the main purpose of MGTs in FPGA is to achieve high-speed data transmission, the delay stability, especially after initialization/reset operations, is not sufficiently considered. The Xilinx MGTs can be configured in different modes for flexibility. Since Xilinx does not fully explain the implementation structure of each mode, the delay characteristics must be investigated experimentally to achieve high-performance clock transmission. This paper presents a comprehensive investigation of the delay instabilities in Xilinx MGTs and proposes countermeasures to minimize them for stable clock and data transmission. Additionally, a method is proposed to obtain a high-quality recovered clock directly from Xilinx UltraScale and higher-level FPGAs, eliminating the need for an off-chip jitter cleaner. The test results indicate that high clock distribution and synchronization performance can be achieved over the MGT-based serial link once the delay instabilities are properly addressed.


  • An FPGA-Based 64-Channel Readout Electronics for High-Resolution TOF-PET Detectors

    by Xiang Zhang, Yonggang Wang, Mingchen Wang, Xiaoguang Kong

    Field programmable logic array (FPGA) based readout electronics has shown its capability of channel-bychannel signal readout for time-of-flight positron emission tomography (TOF-PET) detectors. However, for detectors that rely on light sharing to achieve sub-pixel resolution, the high linear measurement dynamic range of the readout electronics is highly required. In this paper, the problems with dynamic range in our previously proposed FPGA-based fast linear discharge circuit are investigated and corresponding methods are proposed to enhance its small signal measurement capability and improve the timing performance as well. A practical 64-channel TOF-PET detector module was constructed and evaluated. The readout electronics test results demonstrated a 240x measurement dynamic range with 99.5% conversion linearity. In the case that the 8×8 silicon photomultiplier (SiPM) array in the detector combines with an 8×8 LYSO crystal (each 3.2×3.2×10mm3) array, the average energy and coincidence time resolution of the detector are measured as 10.68% (511keV) and 364.9ps respectively. To demonstrate the benefit of large dynamic range to high-resolution detectors, the crystal array in the detector was replaced by a 24×24 LYSO array (each 1.04×1.04×15mm3) and achieved 1mm resolution. The test results confirm that the proposed FPGA-based readout circuit is practical for laboratory instrumentation.