Huandong Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huandong Huang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Xiang Zhang
Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics (Hefei), University of Science and Technology of China, Hefei, Anhui, China
2 shared publications - Yonggang Wang
Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui, China
2 shared publications - Xinchi Xu
Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, China
1 shared publication - Yonghang Zhou
Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, China
1 shared publication - Zhengqi Song
Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, China
1 shared publication
Latest Publications
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
An FPGA-based Scalable Coincidence Processor for High Count-rate PET Systems
A hardware-based coincidence processor (CP) is essential for a high count-rate positron emission tomography (PET) with multiple detectors. This paper presents a scalable design and implementation of such a CP based on a Xilinx UltraScale Field Programmable Gate Array (FPGA). By dividing the detector ring into six sectors, a distributed coincidence processing with 15 parallel coincidence selectors is implemented to balance between processor throughput and hardware resource consumption. To simplify the selector structure, detection events from the detector modules within the same sector must be sorted before entering the processor. Since all the selectors and sorters are adjustable, the system is manually configurable in terms of field-of-view (FOV) and the number of inputs. In the current design, each sector sorter can handle up to 8 detector modules, therefore the CP can be configured to connect a maximum of 48 detector modules. The functionality and performance of the proposed CP are evaluated with both simulation and experimental data. The test results show that the system throughput can reach 750 Mcps, meanwhile the resource consumption is less than 20% of the chip resources. The configurability and scalability of the CP enable it to meet the needs of PETs with different scales.
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
An FPGA-based Scalable Coincidence Processor for High Count-rate PET Systems
A hardware-based coincidence processor (CP) is essential for a high count-rate positron emission tomography (PET) with multiple detectors. This paper presents a scalable design and implementation of such a CP based on a Xilinx UltraScale Field Programmable Gate Array (FPGA). By dividing the detector ring into six sectors, a distributed coincidence processing with 15 parallel coincidence selectors is implemented to balance between processor throughput and hardware resource consumption. To simplify the selector structure, detection events from the detector modules within the same sector must be sorted before entering the processor. Since all the selectors and sorters are adjustable, the system is manually configurable in terms of field-of-view (FOV) and the number of inputs. In the current design, each sector sorter can handle up to 8 detector modules, therefore the CP can be configured to connect a maximum of 48 detector modules. The functionality and performance of the proposed CP are evaluated with both simulation and experimental data. The test results show that the system throughput can reach 750 Mcps, meanwhile the resource consumption is less than 20% of the chip resources. The configurability and scalability of the CP enable it to meet the needs of PETs with different scales.
- 9 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 73 (2) , 961-971
A Low-Power 8×8 SiPM Readout ASIC With Row-Column Summing Structure for Compact TOF-PET Detectors
A new low-power 64-channel Front-End application-specific integrated circuit (ASIC) for the readout of $8\times 8$ Silicon photomultiplier (SiPM) Arrays (FESA) with a row-column summing structure is proposed for flexibly building a compact and cost-effective time-of-flight (TOF) positron emission tomography (PET) system. The inputs from the SiPM array are picked up individually and row-column summed to reduce the number of measurement circuits and overall power consumption. An energy-to-time conversion circuit based on the delayed linear discharge method is proposed with high linearity and enhanced small-signal measurement ability, which allows FESA to use a fully time-based readout strategy so that a simple and robust interface for system-level integration is provided. Fabricated in 180 nm CMOS technology, FESA has been evaluated with an intrinsic timing jitter of 11.8 ps, a dynamic energy measurement range of 44 dB, a power consumption of 2.39 mW per channel, and an event rate of 4 MS/s. With an $8\times 8$ Hamamatsu S13361-3050 SiPM array 1:1 coupled to an $8\times 8$ lutetium yttrium oxyorthosilicate (LYSO) crystal array, the FESA-based detector exhibits a coincidence time resolution (CTR) of 237 ps FWHM and an energy resolution of 12.6%. The measured flood image with an $8\times 8$ SiPM array 1:9 coupled to a $24\times 24$ LYSO crystal array demonstrates the ability of FESA to decode a crystal size of 1 mm. The test results show that FESA is a promising candidate for the future construction of high-performance and high-integration TOF-PET systems.
- 9 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 73 (2) , 961-971
A Low-Power 8×8 SiPM Readout ASIC With Row-Column Summing Structure for Compact TOF-PET Detectors
A new low-power 64-channel Front-End application-specific integrated circuit (ASIC) for the readout of $8\times 8$ Silicon photomultiplier (SiPM) Arrays (FESA) with a row-column summing structure is proposed for flexibly building a compact and cost-effective time-of-flight (TOF) positron emission tomography (PET) system. The inputs from the SiPM array are picked up individually and row-column summed to reduce the number of measurement circuits and overall power consumption. An energy-to-time conversion circuit based on the delayed linear discharge method is proposed with high linearity and enhanced small-signal measurement ability, which allows FESA to use a fully time-based readout strategy so that a simple and robust interface for system-level integration is provided. Fabricated in 180 nm CMOS technology, FESA has been evaluated with an intrinsic timing jitter of 11.8 ps, a dynamic energy measurement range of 44 dB, a power consumption of 2.39 mW per channel, and an event rate of 4 MS/s. With an $8\times 8$ Hamamatsu S13361-3050 SiPM array 1:1 coupled to an $8\times 8$ lutetium yttrium oxyorthosilicate (LYSO) crystal array, the FESA-based detector exhibits a coincidence time resolution (CTR) of 237 ps FWHM and an energy resolution of 12.6%. The measured flood image with an $8\times 8$ SiPM array 1:9 coupled to a $24\times 24$ LYSO crystal array demonstrates the ability of FESA to decode a crystal size of 1 mm. The test results show that FESA is a promising candidate for the future construction of high-performance and high-integration TOF-PET systems.