Charly Feldman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Charly Feldman has a total of 433 co-authors. Here are the top co-authors by number of shared publications:
- Michael W. J. Hubbard
The Open Univ. (United Kingdom)
2 shared publications - Rene Hudec
Czech Technical University in Prague
2 shared publications - A. A. Kokomov
Ioffe Institute, St. Petersburg, Russia
1 shared publication A. A. Nordt
Lockheed Martin (United States)
1 shared publication- A. Balado
National Institute of Aerospace Technology, Madrid, Spain
1 shared publication A. Bhardwaj
Physical Research Lab. (India)
1 shared publication
Latest Publications
- Open Access
- 18 November 2025
- Published by Springer Nature in Space Science Reviews
- Vol. 221 (8) , 113
The Soft X-ray Imager (SXI) on the SMILE Mission
The Soft X-ray Imager (SXI) is a compact X-ray telescope with a wide $15.5^{\circ } \times 26.5^{\circ }$ field-of-view (FOV) and is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer (SMILE) mission. SMILE is a joint science mission between the European Space Agency (ESA) and the Chinese Academy of Sciences (CAS) and is due for launch in 2026. SXI is capable of viewing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit. SXI is designed to detect the soft X-rays from the Solar Wind Charge eXchange (SWCX) process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere. SWCX provides a mechanism for boundary detection within the magnetosphere, such as the position of Earth’s magnetopause, because the solar wind heavy ions essentially do not enter regions of closed magnetic field lines. The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours. The SXI has a large grasp (FOV times effective area) and a CCD-based detector system with an energy resolution comparable to contemporary X-ray astrophysics missions. SXI will, therefore, acquire high precision spectra capable of discriminating the composition of many of the solar wind heavy ions within the regions of interest. SXI is led by the University of Leicester (UL) in the United Kingdom (UK) with collaborating organisations on hardware, software and science support within the UK, Europe, China and the United States.- 18 November 2025
- Published by Springer Nature in Space Science Reviews
- Vol. 221 (8) , 113
Open AccessThe Soft X-ray Imager (SXI) on the SMILE Mission
The Soft X-ray Imager (SXI) is a compact X-ray telescope with a wide $15.5^{\circ } \times 26.5^{\circ }$ field-of-view (FOV) and is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer (SMILE) mission. SMILE is a joint science mission between the European Space Agency (ESA) and the Chinese Academy of Sciences (CAS) and is due for launch in 2026. SXI is capable of viewing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit. SXI is designed to detect the soft X-rays from the Solar Wind Charge eXchange (SWCX) process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere. SWCX provides a mechanism for boundary detection within the magnetosphere, such as the position of Earth’s magnetopause, because the solar wind heavy ions essentially do not enter regions of closed magnetic field lines. The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours. The SXI has a large grasp (FOV times effective area) and a CCD-based detector system with an energy resolution comparable to contemporary X-ray astrophysics missions. SXI will, therefore, acquire high precision spectra capable of discriminating the composition of many of the solar wind heavy ions within the regions of interest. SXI is led by the University of Leicester (UL) in the United Kingdom (UK) with collaborating organisations on hardware, software and science support within the UK, Europe, China and the United States. - Top Cited Papers
- 23 January 2025
- Published by Springer Nature in Nature Astronomy
- Vol. 9 (4) , 564-576
Soft X-ray prompt emission from the high-redshift gamma-ray burst EP240315a
- 23 January 2025
- Published by Springer Nature in Nature Astronomy
- Vol. 9 (4) , 564-576
Top Cited PapersSoft X-ray prompt emission from the high-redshift gamma-ray burst EP240315a
- 21 August 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13093, 82-730
The Line Emission Mapper (LEM) probe mission concept
The Line Emission Mapper (LEM) is a Probe mission concept developed in response to NASA’s Astrophysics Probe Explorer (APEX) Announcement of Opportunity. LEM has a single science instrument composed of a large-area, wide-field X-ray optic and a microcalorimeter X-ray imaging spectrometer in the focal plane. LEM is optimized to observe low-surface-brightness diffuse X-ray emission over a 30′ equivalent diameter field of view with 1.3 and 2.5 eV spectral resolution in the 0.2−2.0 keV band. Our primary scientific objective is to map the thermal, kinetic, and elemental properties of the diffuse gas in the extended X-ray halos of galaxies, the outskirts of galaxy clusters, the filamentary structures between these clusters, the Milky Way star-formation regions, the Galactic halo, and supernova remnants in the Milky Way and Local Group. The combination of a wide-field optic with 18′′ angular resolution end-to-end and a microcalorimeter array with 1.3 eV spectral resolution in a 5′ × 5′ inner array (2.5 eV outside of that) offers unprecedented sensitivity to extended low-surface-brightness X-ray emission. This allows us to study feedback processes, gas dynamics, and metal enrichment over seven orders of magnitude in spatial scales, from parsecs to tens of megaparsecs. LEM will spend approximately 11% of its five-year prime science mission performing an All-Sky Survey, the first all-sky X-ray survey at high spectral resolution. The remainder of the five-year science mission will be divided between directed science (30%) and competed General Observer science (70%). LEM and the NewAthena/XIFU are highly complementary, with LEM’s optimization for soft X-rays, large FOV, 1.3 eV spectral resolution, and large grasp balancing the NewAthena/X-IFU’s broadband sensitivity, large effective area, and unprecedented spectral resolving power at 6 keV. In this presentation, we will provide an overview of the mission architecture, the directed science driving the mission design, and the broad scope these capabilities offer to the entire astrophysics community.
- 21 August 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13093, 82-730
The Line Emission Mapper (LEM) probe mission concept
The Line Emission Mapper (LEM) is a Probe mission concept developed in response to NASA’s Astrophysics Probe Explorer (APEX) Announcement of Opportunity. LEM has a single science instrument composed of a large-area, wide-field X-ray optic and a microcalorimeter X-ray imaging spectrometer in the focal plane. LEM is optimized to observe low-surface-brightness diffuse X-ray emission over a 30′ equivalent diameter field of view with 1.3 and 2.5 eV spectral resolution in the 0.2−2.0 keV band. Our primary scientific objective is to map the thermal, kinetic, and elemental properties of the diffuse gas in the extended X-ray halos of galaxies, the outskirts of galaxy clusters, the filamentary structures between these clusters, the Milky Way star-formation regions, the Galactic halo, and supernova remnants in the Milky Way and Local Group. The combination of a wide-field optic with 18′′ angular resolution end-to-end and a microcalorimeter array with 1.3 eV spectral resolution in a 5′ × 5′ inner array (2.5 eV outside of that) offers unprecedented sensitivity to extended low-surface-brightness X-ray emission. This allows us to study feedback processes, gas dynamics, and metal enrichment over seven orders of magnitude in spatial scales, from parsecs to tens of megaparsecs. LEM will spend approximately 11% of its five-year prime science mission performing an All-Sky Survey, the first all-sky X-ray survey at high spectral resolution. The remainder of the five-year science mission will be divided between directed science (30%) and competed General Observer science (70%). LEM and the NewAthena/XIFU are highly complementary, with LEM’s optimization for soft X-rays, large FOV, 1.3 eV spectral resolution, and large grasp balancing the NewAthena/X-IFU’s broadband sensitivity, large effective area, and unprecedented spectral resolving power at 6 keV. In this presentation, we will provide an overview of the mission architecture, the directed science driving the mission design, and the broad scope these capabilities offer to the entire astrophysics community.
- Open Access
- 1 July 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 10 (03) , 034003-16
Impact of particle passage and focusing from micro-pore optics for radiation damage estimates
Space observatories utilizing micro pore optics (MPOs) have been used and are planned for several future X-ray astronomy space missions. The optical systems are designed to facilitate the focusing of incoming photons onto the focal plane of telescopes. Unfortunately, as well as having a small solid angle “open” to the sky, MPOs also have the unintentional effect of focusing high-energy particles from the space radiation environment. This causes additional radiation damage to mission-critical imaging sensors with solar energetic particles being particularly focusable. Typically, processes such as sectoral analysis are used to estimate the predicted dose to components, which is a ray tracing approach, and does not include focusing effects. We investigated focused dose estimation techniques for MPOs using Monte Carlo (MC) simulations. The focused dose contribution was compared with the unfocused contribution for the Solar wind Magnetosphere Ionosphere Link Explorer mission. The unfocused dose estimates were calculated using a traditional sectoral shielding analysis. The Monte Carlo-focused dose simulations enabled dose mapping over the image sensor to be analyzed. This revealed a relatively uniform dose across the device with some focusing artifacts present. The simulations also showed that the total ionizing dose and total non-ionizing dose decreased with depth into the sensor from the entrance window. This is key when considering that charge is often stored at varying depths in imaging devices across different technologies, for example, in front or back illuminated devices.
- 1 July 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 10 (03) , 034003-16
Open AccessImpact of particle passage and focusing from micro-pore optics for radiation damage estimates
Space observatories utilizing micro pore optics (MPOs) have been used and are planned for several future X-ray astronomy space missions. The optical systems are designed to facilitate the focusing of incoming photons onto the focal plane of telescopes. Unfortunately, as well as having a small solid angle “open” to the sky, MPOs also have the unintentional effect of focusing high-energy particles from the space radiation environment. This causes additional radiation damage to mission-critical imaging sensors with solar energetic particles being particularly focusable. Typically, processes such as sectoral analysis are used to estimate the predicted dose to components, which is a ray tracing approach, and does not include focusing effects. We investigated focused dose estimation techniques for MPOs using Monte Carlo (MC) simulations. The focused dose contribution was compared with the unfocused contribution for the Solar wind Magnetosphere Ionosphere Link Explorer mission. The unfocused dose estimates were calculated using a traditional sectoral shielding analysis. The Monte Carlo-focused dose simulations enabled dose mapping over the image sensor to be analyzed. This revealed a relatively uniform dose across the device with some focusing artifacts present. The simulations also showed that the total ionizing dose and total non-ionizing dose decreased with depth into the sensor from the entrance window. This is key when considering that charge is often stored at varying depths in imaging devices across different technologies, for example, in front or back illuminated devices.