Curtis Geffner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Curtis Geffner has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Boris Stoeber
Department of Mechanical Engineering, The University of British Columbia, Vancouver, Canada
1 shared publication - Martina Iapichino
Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada
1 shared publication - Matthew Jaffey
Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada
1 shared publication - Mattia Bacca
Mechanical Engineering Department, University of British Columbia, Vancouver, BC V6T1Z4, Canada
1 shared publication - Pranav Shrestha
Department of Mechanical Engineering, The University of British Columbia, Vancouver, Canada
1 shared publication - Zhongnan Wu
Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada
1 shared publication
Latest Publications
- 17 June 2024
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 20 (27) , 5377-5388
Force decomposition and toughness estimation from puncture experiments in soft solids
Several medical applications, like drug delivery and biosensing, are critically preceded by the insertion of needles and microneedles into biological tissue. However, the mechanical process of needle insertions, especially at high velocities, is currently not fully understood. Here, we explore the insertion of hollow needles into transparent silicone samples with an insertion velocity v ranging from 0.1 mm s−1 to 2.3 m s−1 (with needle radius R = 101.5 μm, thus strain rates ∼v/R ranging from 1 s−1 to 2.3 × 104 s−1). We use a double-insertion method, where the needle is inserted and re-inserted at the same location, to estimate the fracture properties of the material. The deflection of the specimen's free surface is found to be different between insertion and re-insertion experiments for identical needle positions, which is associated with different force magnitudes between insertion/reinsertion. This aspect was previously neglected in the original double-insertion method, thus here we develop a method based on imaging, image analyses and force measurements to decompose the measured force into individual force components, including deflection force Fd, frictional and spreading force Ff + Fs, and cutting force Ft. We estimate that the toughness Γ of our silicone samples, calculated using the cutting force Ft and the crack dimensions, increases with needle velocity, and ranges within observed values in previous literature for the same material and for some soft biological materials. In addition to toughness Γ, other parameters, such as critical force Fc and mechanical work Wc, also show strain-rate dependence, suggesting tissue stiffening, due to accumulated strain energy, at high speeds.
- 17 June 2024
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 20 (27) , 5377-5388
Force decomposition and toughness estimation from puncture experiments in soft solids
Several medical applications, like drug delivery and biosensing, are critically preceded by the insertion of needles and microneedles into biological tissue. However, the mechanical process of needle insertions, especially at high velocities, is currently not fully understood. Here, we explore the insertion of hollow needles into transparent silicone samples with an insertion velocity v ranging from 0.1 mm s−1 to 2.3 m s−1 (with needle radius R = 101.5 μm, thus strain rates ∼v/R ranging from 1 s−1 to 2.3 × 104 s−1). We use a double-insertion method, where the needle is inserted and re-inserted at the same location, to estimate the fracture properties of the material. The deflection of the specimen's free surface is found to be different between insertion and re-insertion experiments for identical needle positions, which is associated with different force magnitudes between insertion/reinsertion. This aspect was previously neglected in the original double-insertion method, thus here we develop a method based on imaging, image analyses and force measurements to decompose the measured force into individual force components, including deflection force Fd, frictional and spreading force Ff + Fs, and cutting force Ft. We estimate that the toughness Γ of our silicone samples, calculated using the cutting force Ft and the crack dimensions, increases with needle velocity, and ranges within observed values in previous literature for the same material and for some soft biological materials. In addition to toughness Γ, other parameters, such as critical force Fc and mechanical work Wc, also show strain-rate dependence, suggesting tissue stiffening, due to accumulated strain energy, at high speeds.