Chongyang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chongyang Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jiang Zhu
Beijing Information Science and Technology University
4 shared publications - Fan Fan
Beijing Information Science and Technology University
3 shared publications - Xiaochen Meng
Beijing Information Science and Technology University
3 shared publications - Zongqing Ma
Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University 1 , Beijing 100192
3 shared publications - Jiawei Ma
Beijing Information Science and Technology University
2 shared publications - Fan Zhang
School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, China
1 shared publication
Latest Publications
- 13 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (15)
Elasticity assessment of intestinal tissues using endoscopic optical coherence elastography
Strain-based optical coherence elastography (OCE) is a functional imaging modality derived from optical coherence tomography (OCT), which evaluates biomechanical properties by measuring tissue strain. However, conventional Doppler phase-based strain estimation is highly susceptible to phase wrapping, particularly under conditions of unstable scanning speed, which is often exacerbated by non-uniform rotational distortion (NURD) in proximally driven endoscopic probes. To overcome these limitations, we propose a distal rotary scanning endoscopic OCE system integrated with a balloon catheter. By combining balloon inflation-induced excitation with circumferential scanning, the system enables stable and uniform elastography imaging of intestinal tissue while mitigating NURD-related artifacts. Displacement fields are estimated by calculating inter-frame phase differences of OCT images, based on which radial strain maps are reconstructed, thereby simplifying the phase-unwrapping process. Experiments conducted on tissue-mimicking phantoms and ex vivo porcine intestines confirm the feasibility of the proposed method. The results indicate that the system can simultaneously capture high-resolution structural images and radial strain information from localized intestinal tissues, demonstrating significant potential for clinical applications in the early diagnosis and therapeutic monitoring of intestinal diseases.
- 13 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (15)
Elasticity assessment of intestinal tissues using endoscopic optical coherence elastography
Strain-based optical coherence elastography (OCE) is a functional imaging modality derived from optical coherence tomography (OCT), which evaluates biomechanical properties by measuring tissue strain. However, conventional Doppler phase-based strain estimation is highly susceptible to phase wrapping, particularly under conditions of unstable scanning speed, which is often exacerbated by non-uniform rotational distortion (NURD) in proximally driven endoscopic probes. To overcome these limitations, we propose a distal rotary scanning endoscopic OCE system integrated with a balloon catheter. By combining balloon inflation-induced excitation with circumferential scanning, the system enables stable and uniform elastography imaging of intestinal tissue while mitigating NURD-related artifacts. Displacement fields are estimated by calculating inter-frame phase differences of OCT images, based on which radial strain maps are reconstructed, thereby simplifying the phase-unwrapping process. Experiments conducted on tissue-mimicking phantoms and ex vivo porcine intestines confirm the feasibility of the proposed method. The results indicate that the system can simultaneously capture high-resolution structural images and radial strain information from localized intestinal tissues, demonstrating significant potential for clinical applications in the early diagnosis and therapeutic monitoring of intestinal diseases.
- 5 May 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (18)
Corneal viscoelasticity measurements under different intraocular pressures using handheld optical coherence elastography
Accurate measurement of corneal viscoelasticity is essential for diagnosing ocular diseases and understanding corneal biomechanics. Optical coherence elastography (OCE) is a promising technique for high-resolution imaging and quantitative assessment of tissue elasticity. However, existing OCE methods often struggle to provide comprehensive viscoelastic measurements of the cornea under varying intraocular pressures (IOPs). In this study, we present a method based on elastic wave dispersion for measuring corneal viscoelasticity using a handheld OCE system integrating non-contact air-puff excitation and a compact probe design. The elastic wave dispersion method, validated through experiments on agar phantoms, enables precise quantification of both elastic and viscous properties of the cornea. The system's effectiveness was further demonstrated by measuring corneal viscoelasticity in ex vivo porcine corneas at different IOPs. Our results show that the elastic wave dispersion method, combined with the handheld OCE system, provides a flexible and effective approach for assessing corneal viscoelasticity, offering valuable insights into corneal biomechanics under clinically relevant conditions.
- 5 May 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (18)
Corneal viscoelasticity measurements under different intraocular pressures using handheld optical coherence elastography
Accurate measurement of corneal viscoelasticity is essential for diagnosing ocular diseases and understanding corneal biomechanics. Optical coherence elastography (OCE) is a promising technique for high-resolution imaging and quantitative assessment of tissue elasticity. However, existing OCE methods often struggle to provide comprehensive viscoelastic measurements of the cornea under varying intraocular pressures (IOPs). In this study, we present a method based on elastic wave dispersion for measuring corneal viscoelasticity using a handheld OCE system integrating non-contact air-puff excitation and a compact probe design. The elastic wave dispersion method, validated through experiments on agar phantoms, enables precise quantification of both elastic and viscous properties of the cornea. The system's effectiveness was further demonstrated by measuring corneal viscoelasticity in ex vivo porcine corneas at different IOPs. Our results show that the elastic wave dispersion method, combined with the handheld OCE system, provides a flexible and effective approach for assessing corneal viscoelasticity, offering valuable insights into corneal biomechanics under clinically relevant conditions.
- 23 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (13)
Anisotropic elasticity measurements of the retina using optical coherence elastography
Anisotropic elasticity measurements of the retina are essential for retinal disease diagnosis and function assessment. Optical coherence elastography (OCE) is a high-resolution imaging technique for mapping the elasticity distribution of tissues. However, previous OCE measurements quantified the tissue elasticity in a single direction, resulting in a biased estimation of the elastic properties. In this study, we propose an OCE method with acoustic radiation force (ARF) excitation to map the retinal anisotropic elasticity in the depth and lateral directions. The axial elasticity was analyzed using the natural frequency of free vibration, and the lateral elasticity was quantified using the elastic wave velocity. After evaluating the feasibility of the OCE method on the phantoms, the anisotropic elasticity of ex vivo porcine retinas was mapped. The results show that the OCE method with ARF excitation can assess the elasticity in orthogonal directions and provide a comprehensive understanding of the elasticity of the anisotropic tissues.
- 23 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (13)
Anisotropic elasticity measurements of the retina using optical coherence elastography
Anisotropic elasticity measurements of the retina are essential for retinal disease diagnosis and function assessment. Optical coherence elastography (OCE) is a high-resolution imaging technique for mapping the elasticity distribution of tissues. However, previous OCE measurements quantified the tissue elasticity in a single direction, resulting in a biased estimation of the elastic properties. In this study, we propose an OCE method with acoustic radiation force (ARF) excitation to map the retinal anisotropic elasticity in the depth and lateral directions. The axial elasticity was analyzed using the natural frequency of free vibration, and the lateral elasticity was quantified using the elastic wave velocity. After evaluating the feasibility of the OCE method on the phantoms, the anisotropic elasticity of ex vivo porcine retinas was mapped. The results show that the OCE method with ARF excitation can assess the elasticity in orthogonal directions and provide a comprehensive understanding of the elasticity of the anisotropic tissues.
- 26 August 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (9)
Rapid non-contact viscosity measurement based on optical coherence tomography
Viscosity measurement is crucial in biomedical research and clinical diagnosis. Currently, rapid and non-contact methods for measuring viscosity remain challenging. We propose a method based on optical coherence tomography for fast, remote assessment of the liquid viscosity. The viscosity of the liquid sample was quantified according to Poiseuille's law, the flow velocity was determined using optical coherence tomography, and the real-time pressure difference was measured by two manometers. Glycerol–water mixtures with various viscosities were tested to assess the accuracy of the optical coherence tomography (OCT) viscosity measurement. Then, blood samples with different levels of hemodilution and hematocrit were measured to validate the feasibility of the OCT method in the blood viscosity measurement. The results indicate that the proposed method can provide rapid, non-contact liquid viscosity measurement. It could significantly impact research on hemodynamics and diagnosis of blood disorders.
- 26 August 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (9)
Rapid non-contact viscosity measurement based on optical coherence tomography
Viscosity measurement is crucial in biomedical research and clinical diagnosis. Currently, rapid and non-contact methods for measuring viscosity remain challenging. We propose a method based on optical coherence tomography for fast, remote assessment of the liquid viscosity. The viscosity of the liquid sample was quantified according to Poiseuille's law, the flow velocity was determined using optical coherence tomography, and the real-time pressure difference was measured by two manometers. Glycerol–water mixtures with various viscosities were tested to assess the accuracy of the optical coherence tomography (OCT) viscosity measurement. Then, blood samples with different levels of hemodilution and hematocrit were measured to validate the feasibility of the OCT method in the blood viscosity measurement. The results indicate that the proposed method can provide rapid, non-contact liquid viscosity measurement. It could significantly impact research on hemodynamics and diagnosis of blood disorders.