Jiawei Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiawei Ma has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Fan Fan
Beijing Information Science and Technology University
4 shared publications - Jiang Zhu
Beijing Information Science and Technology University
4 shared publications - Xiaochen Meng
Beijing Information Science and Technology University
4 shared publications - Chongyang Wang
Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University 1 , Beijing 100192
2 shared publications Zongqing Ma
Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instruments, Beijing Information Science and Technology University 1 , Beijing 100192
2 shared publications- Zongqing Ma
Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University 1 , Beijing 100192
2 shared publications
Latest Publications
- 1 June 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (22)
Extended depth of focus for optical coherence tomography based on the versatile diffractive optical element
Optical coherence tomography (OCT) faces a fundamental trade-off between transverse resolution and depth of focus (DOF). While diffractive optical elements (DOEs) have been utilized to extend the DOF, existing designs are typically customized for specific objective lenses, limiting their versatility. We propose an extended-DOF OCT system utilizing a configuration-independent DOE. By modulating the incident wavefront to evenly distribute beam energy along the optical axis, the DOE extends the DOF without requiring redesign when applied to different optical setups. Simulations and experiments demonstrate that the integration of a single DOE across different sample arms more than doubles the effective DOF while maintaining diffraction-limited lateral resolution. The improved deep-tissue and large-field-of-view imaging capabilities are validated through resolution targets, cleared tissues, and in vivo OCT angiography of the murine cerebral cortex and human nailfold microcirculation. Quantitative evaluations reveal significant improvements in the contrast-to-noise ratio and vascular density (VD). The proposed system offers a highly adaptable solution for high-resolution, extended-DOF OCT imaging, demonstrating significant potential for preclinical and clinical applications.
- 1 June 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (22)
Extended depth of focus for optical coherence tomography based on the versatile diffractive optical element
Optical coherence tomography (OCT) faces a fundamental trade-off between transverse resolution and depth of focus (DOF). While diffractive optical elements (DOEs) have been utilized to extend the DOF, existing designs are typically customized for specific objective lenses, limiting their versatility. We propose an extended-DOF OCT system utilizing a configuration-independent DOE. By modulating the incident wavefront to evenly distribute beam energy along the optical axis, the DOE extends the DOF without requiring redesign when applied to different optical setups. Simulations and experiments demonstrate that the integration of a single DOE across different sample arms more than doubles the effective DOF while maintaining diffraction-limited lateral resolution. The improved deep-tissue and large-field-of-view imaging capabilities are validated through resolution targets, cleared tissues, and in vivo OCT angiography of the murine cerebral cortex and human nailfold microcirculation. Quantitative evaluations reveal significant improvements in the contrast-to-noise ratio and vascular density (VD). The proposed system offers a highly adaptable solution for high-resolution, extended-DOF OCT imaging, demonstrating significant potential for preclinical and clinical applications.
- 9 February 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (4) , 1001-1004
Forward-scanning endoscopic optical coherence elastography for elasticity measurements of anisotropic tissues
The elasticity of luminal tissues is closely associated with disease progression and functional status. Endoscopic optical coherence elastography (OCE) has emerged as a promising technique for assessing the mechanical properties of luminal tissues. However, previous endoscopic OCE approaches typically measure elasticity along only a single direction—either laterally or in depth—thereby potentially leading to an inaccurate estimation of anisotropic tissue mechanics. In this study, we propose a forward-scanning endoscopic OCE method that enables quantitative measurement of tissue elasticity in both the lateral and depth directions, allowing direct characterization of anisotropic mechanical properties in luminal tissues. An air-pulse excitation was applied to generate Rayleigh waves and longitudinal shear waves in agar phantoms and ex vivo gastric tissues. Elastic wave propagation was detected using phase-resolved Doppler optical coherence tomography. Experimental results demonstrate that the proposed method can quantitatively assess anisotropic elasticity with a forward-viewing configuration, highlighting its potential for clinical diagnosis and biomechanical characterization of luminal tissues.
- 9 February 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (4) , 1001-1004
Forward-scanning endoscopic optical coherence elastography for elasticity measurements of anisotropic tissues
The elasticity of luminal tissues is closely associated with disease progression and functional status. Endoscopic optical coherence elastography (OCE) has emerged as a promising technique for assessing the mechanical properties of luminal tissues. However, previous endoscopic OCE approaches typically measure elasticity along only a single direction—either laterally or in depth—thereby potentially leading to an inaccurate estimation of anisotropic tissue mechanics. In this study, we propose a forward-scanning endoscopic OCE method that enables quantitative measurement of tissue elasticity in both the lateral and depth directions, allowing direct characterization of anisotropic mechanical properties in luminal tissues. An air-pulse excitation was applied to generate Rayleigh waves and longitudinal shear waves in agar phantoms and ex vivo gastric tissues. Elastic wave propagation was detected using phase-resolved Doppler optical coherence tomography. Experimental results demonstrate that the proposed method can quantitatively assess anisotropic elasticity with a forward-viewing configuration, highlighting its potential for clinical diagnosis and biomechanical characterization of luminal tissues.
- 5 May 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (18)
Corneal viscoelasticity measurements under different intraocular pressures using handheld optical coherence elastography
Accurate measurement of corneal viscoelasticity is essential for diagnosing ocular diseases and understanding corneal biomechanics. Optical coherence elastography (OCE) is a promising technique for high-resolution imaging and quantitative assessment of tissue elasticity. However, existing OCE methods often struggle to provide comprehensive viscoelastic measurements of the cornea under varying intraocular pressures (IOPs). In this study, we present a method based on elastic wave dispersion for measuring corneal viscoelasticity using a handheld OCE system integrating non-contact air-puff excitation and a compact probe design. The elastic wave dispersion method, validated through experiments on agar phantoms, enables precise quantification of both elastic and viscous properties of the cornea. The system's effectiveness was further demonstrated by measuring corneal viscoelasticity in ex vivo porcine corneas at different IOPs. Our results show that the elastic wave dispersion method, combined with the handheld OCE system, provides a flexible and effective approach for assessing corneal viscoelasticity, offering valuable insights into corneal biomechanics under clinically relevant conditions.
- 5 May 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (18)
Corneal viscoelasticity measurements under different intraocular pressures using handheld optical coherence elastography
Accurate measurement of corneal viscoelasticity is essential for diagnosing ocular diseases and understanding corneal biomechanics. Optical coherence elastography (OCE) is a promising technique for high-resolution imaging and quantitative assessment of tissue elasticity. However, existing OCE methods often struggle to provide comprehensive viscoelastic measurements of the cornea under varying intraocular pressures (IOPs). In this study, we present a method based on elastic wave dispersion for measuring corneal viscoelasticity using a handheld OCE system integrating non-contact air-puff excitation and a compact probe design. The elastic wave dispersion method, validated through experiments on agar phantoms, enables precise quantification of both elastic and viscous properties of the cornea. The system's effectiveness was further demonstrated by measuring corneal viscoelasticity in ex vivo porcine corneas at different IOPs. Our results show that the elastic wave dispersion method, combined with the handheld OCE system, provides a flexible and effective approach for assessing corneal viscoelasticity, offering valuable insights into corneal biomechanics under clinically relevant conditions.
- 23 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (13)
Anisotropic elasticity measurements of the retina using optical coherence elastography
Anisotropic elasticity measurements of the retina are essential for retinal disease diagnosis and function assessment. Optical coherence elastography (OCE) is a high-resolution imaging technique for mapping the elasticity distribution of tissues. However, previous OCE measurements quantified the tissue elasticity in a single direction, resulting in a biased estimation of the elastic properties. In this study, we propose an OCE method with acoustic radiation force (ARF) excitation to map the retinal anisotropic elasticity in the depth and lateral directions. The axial elasticity was analyzed using the natural frequency of free vibration, and the lateral elasticity was quantified using the elastic wave velocity. After evaluating the feasibility of the OCE method on the phantoms, the anisotropic elasticity of ex vivo porcine retinas was mapped. The results show that the OCE method with ARF excitation can assess the elasticity in orthogonal directions and provide a comprehensive understanding of the elasticity of the anisotropic tissues.
- 23 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (13)
Anisotropic elasticity measurements of the retina using optical coherence elastography
Anisotropic elasticity measurements of the retina are essential for retinal disease diagnosis and function assessment. Optical coherence elastography (OCE) is a high-resolution imaging technique for mapping the elasticity distribution of tissues. However, previous OCE measurements quantified the tissue elasticity in a single direction, resulting in a biased estimation of the elastic properties. In this study, we propose an OCE method with acoustic radiation force (ARF) excitation to map the retinal anisotropic elasticity in the depth and lateral directions. The axial elasticity was analyzed using the natural frequency of free vibration, and the lateral elasticity was quantified using the elastic wave velocity. After evaluating the feasibility of the OCE method on the phantoms, the anisotropic elasticity of ex vivo porcine retinas was mapped. The results show that the OCE method with ARF excitation can assess the elasticity in orthogonal directions and provide a comprehensive understanding of the elasticity of the anisotropic tissues.