Yılmaz Tutak
Research Subjects
Yılmaz Tutak has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Bilal Gök
Department of Orthopedics and Traumatology, Mardin Training and Research Hospital, Mardin, Turkey
2 shared publications - Muharrem Kanar
Department of Orthopedics and Traumatology, Sisli Hamidiye Etfal Training and Research Hospital, Health Sciences University, Istanbul 34371, Turkey
1 shared publication
Latest Publications
- Open Access
- 24 September 2024
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 30, e945626
Peroneus Longus vs Hamstring Tendon Autografts in ACL Reconstruction: A Comparative Study of 106 Patients’ Outcomes
BACKGROUND:Anterior cruciate ligament (ACL) reconstruction commonly uses a hamstring tendon autograft, but the peroneus longus tendon can also be used. This study aimed to compare outcomes of anterior cruciate ligament reconstruction in 106 patients using peroneus longus tendon and hamstring tendon autografts. MATERIAL AND METHODS:ACL repair was performed on 54 patients using a hamstring tendon autograft and 52 patients with a peroneus longus tendon autograft. Knee function was assessed using the International Knee Documentation Committee (IKDC) and Lysholm scores, while the ankle was evaluated using the American Orthopedic Foot and Ankle Score (AOFAS) and the Foot & Ankle Disability Index (FADI) scores. Donor-site morbidity and graft characteristics were compared. RESULTS:There was no difference between the 2 groups in terms of knee IKDC and Lysholm scores (p=0.49, p=0.68, respectively). The diameter of the peroneus longus tendon graft (8.56±0.93) was significantly larger than the hamstring tendon (7.44±0.6) (p<0.001). The peroneus graft harvesting time was significantly shorter (p<0.001). Thigh hypotrophy and donor-site morbidity were significantly higher in the hamstring group (p<0.001 and p=0.006). The donor ankle AOFAS score was 93.46±3.8, and the FADI score was 93.48±4.6. No morbidity associated with the peroneus longus graft was observed. CONCLUSIONS:Patients who underwent ACL reconstruction using the peroneus longus tendon experienced faster knee rehabilitation and less donor-site morbidity, such as thigh hypotrophy and knee pain. The peroneus longus tendon, with its larger diameter, fewer graft-related complications, and similar knee scores compared to the hamstring group, is considered a suitable alternative graft source.
- 24 September 2024
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 30, e945626
Open AccessPeroneus Longus vs Hamstring Tendon Autografts in ACL Reconstruction: A Comparative Study of 106 Patients’ Outcomes
BACKGROUND:Anterior cruciate ligament (ACL) reconstruction commonly uses a hamstring tendon autograft, but the peroneus longus tendon can also be used. This study aimed to compare outcomes of anterior cruciate ligament reconstruction in 106 patients using peroneus longus tendon and hamstring tendon autografts. MATERIAL AND METHODS:ACL repair was performed on 54 patients using a hamstring tendon autograft and 52 patients with a peroneus longus tendon autograft. Knee function was assessed using the International Knee Documentation Committee (IKDC) and Lysholm scores, while the ankle was evaluated using the American Orthopedic Foot and Ankle Score (AOFAS) and the Foot & Ankle Disability Index (FADI) scores. Donor-site morbidity and graft characteristics were compared. RESULTS:There was no difference between the 2 groups in terms of knee IKDC and Lysholm scores (p=0.49, p=0.68, respectively). The diameter of the peroneus longus tendon graft (8.56±0.93) was significantly larger than the hamstring tendon (7.44±0.6) (p<0.001). The peroneus graft harvesting time was significantly shorter (p<0.001). Thigh hypotrophy and donor-site morbidity were significantly higher in the hamstring group (p<0.001 and p=0.006). The donor ankle AOFAS score was 93.46±3.8, and the FADI score was 93.48±4.6. No morbidity associated with the peroneus longus graft was observed. CONCLUSIONS:Patients who underwent ACL reconstruction using the peroneus longus tendon experienced faster knee rehabilitation and less donor-site morbidity, such as thigh hypotrophy and knee pain. The peroneus longus tendon, with its larger diameter, fewer graft-related complications, and similar knee scores compared to the hamstring group, is considered a suitable alternative graft source.
- Open Access
- 29 July 2024
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 30, e945241-e945241-9
Enhanced Outcomes and Safety of Reverse Shoulder Arthroplasty in Rotator Cuff Deficiency and Proximal Humerus Fractures: A 22-Patient Retrospective Analysis
Background: Reverse shoulder arthroplasty (RSA) is an accepted treatment that provides reproducible results in the treatment of rotator cuff deficiency and proximal humerus fractures. This single-center study aimed to evaluate the outcomes from reverse shoulder arthroplasty for rotator cuff & imath;nsufficiency and proximal humerus fractures in 22 patients from a single center. Material/Methods: Twenty-two patients were included in the study. The median age of the patients was 66 years (Range: 58-95). Proximal humerus fractures were diagnosed using X-ray and CT, while rotator cuff tears were diagnosed using MRI. For the assessment of joint function, the Constant-Murley score, the American Shoulder and Elbow Surgeons (ASES), and the Disabilities of Arm, Shoulder, and Hand (DASH) scores were used as patient-reported outcome measures. Kaplan-Meier analysis was conducted to evaluate implant survival. Results: The mean follow-up duration was 4.05 +/- 1.2 years. Significant improvements were observed: ASES Score: Increased from 35.8 +/- 2.8 to 81.3 +/- 5.4 (p<0.001). VAS Pain Score: Decreased from 7.3 +/- 1 to 2.9 +/- 0.9 (p<0.001). DASH Score: Improved from 66.3 +/- 4.3 to 32.5 +/- 3.6 (p<0.001). Constant-Murley Score: Increased from 48.3 +/- 3.5 to 74.6 +/- 7.7 (p<0.001). Kaplan-Meier analysis estimated implant survival at 6.7 years (95% CI, 6.3-7.2). Conclusions: When performed with appropriate indications, RSA yields positive results, as seen in the literature and our study. Interscalene block anesthesia, advancements in implant technology, and adherence to surgical procedures can reduce RSA complications and ensure its safe application.
- 29 July 2024
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 30, e945241-e945241-9
Open AccessEnhanced Outcomes and Safety of Reverse Shoulder Arthroplasty in Rotator Cuff Deficiency and Proximal Humerus Fractures: A 22-Patient Retrospective Analysis
Background: Reverse shoulder arthroplasty (RSA) is an accepted treatment that provides reproducible results in the treatment of rotator cuff deficiency and proximal humerus fractures. This single-center study aimed to evaluate the outcomes from reverse shoulder arthroplasty for rotator cuff & imath;nsufficiency and proximal humerus fractures in 22 patients from a single center. Material/Methods: Twenty-two patients were included in the study. The median age of the patients was 66 years (Range: 58-95). Proximal humerus fractures were diagnosed using X-ray and CT, while rotator cuff tears were diagnosed using MRI. For the assessment of joint function, the Constant-Murley score, the American Shoulder and Elbow Surgeons (ASES), and the Disabilities of Arm, Shoulder, and Hand (DASH) scores were used as patient-reported outcome measures. Kaplan-Meier analysis was conducted to evaluate implant survival. Results: The mean follow-up duration was 4.05 +/- 1.2 years. Significant improvements were observed: ASES Score: Increased from 35.8 +/- 2.8 to 81.3 +/- 5.4 (p<0.001). VAS Pain Score: Decreased from 7.3 +/- 1 to 2.9 +/- 0.9 (p<0.001). DASH Score: Improved from 66.3 +/- 4.3 to 32.5 +/- 3.6 (p<0.001). Constant-Murley Score: Increased from 48.3 +/- 3.5 to 74.6 +/- 7.7 (p<0.001). Kaplan-Meier analysis estimated implant survival at 6.7 years (95% CI, 6.3-7.2). Conclusions: When performed with appropriate indications, RSA yields positive results, as seen in the literature and our study. Interscalene block anesthesia, advancements in implant technology, and adherence to surgical procedures can reduce RSA complications and ensure its safe application.