BGBilal Gök

Bilal Gök

*This is an algorithmically generated author record based on publicly available information.

Bilal Gök has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Yılmaz Tutak

    Department of Orthopedics and Traumatology, Mardin Training and Research Hospital, Mardin, Turkey

    2 shared publications
  • Muharrem Kanar

    Department of Orthopedics and Traumatology, Şişli Hamidiye Etfal Training and Research Hospital, Istanbul, Türkiye

    1 shared publication
  • Muharrem Kanar

    Department of Orthopedics and Traumatology, Sisli Hamidiye Etfal Training and Research Hospital, Health Sciences University, Istanbul 34371, Turkey

    1 shared publication
  • Osman Tuğrul Eren

    Department of Orthopedics and Traumatology, Şişli Hamidiye Etfal Training and Research Hospital, University of Health Sciences, 34396 Istanbul, Türkiye

    1 shared publication
  • Raffi Armağan

    Department of Orthopedics and Traumatology, Şişli Hamidiye Etfal Training and Research Hospital, Istanbul, Türkiye

    1 shared publication

Latest Publications

  • Open Access

    Comparison of intramedullary nailing versus plate fixation in tibial shaft fractures: A retrospective clinical and radiological analysis

    by Bilal Gök, Muharrem Kanar, Raffi Armağan, Osman Tuğrul Eren

    Aim: Treatment for tibial shaft fractures typically involves plate fixation or intramedullary nailing (IMN). Our objective in this study was to compare the radiological and clinical outcomes of plate fixation with IMN for tibial shaft fractures Method: Fifty-two patients (33 males, 19 females; mean age 36.9±13.8 years; range, 16 to 68 years) who underwent surgery for tibial shaft fracture) between 2003-2011 were retrospectively evaluated. Patients were compared in terms of union time, radiological healing time, weight-bearing time, infection, malunion, and malalignment. Final clinical evaluations of the patients was performed according to the R. Johner and O. Wrush criteria. Results: The average time to weight-bearing was significantly longer in the plate fixation group (7.63±2.27 weeks) compared to the intramedullary nailing group (4.04±1.06 weeks, p=0.000). Similarly, the radiological healing time was longer with plate fixation (12.37 months) by 4.30 months (p=0.000). There were no significant differences in pain between the groups (p=0.535), walking ability (p=0.431), joint range of motion (p=0.243), or strenuous activities (p=0.449). According to the R. Johner and O. Wrush criteria, 68% of patients in both groups achieved excellent outcomes, with the remaining patients having a similar distribution between good and fair categories. Conclusions: The study's findings demonstrated that, in terms of clinical and functional results, both treatment approaches are comparable. Aligning seems to be easier with plates, while the healing period appears to be shorter with IMN. To shed further light on these matters, Randomized Prospective evaluation may be recommended and it may provide detailed information on the costs/expenses associated with these fractures.


  • Open Access

    Peroneus Longus vs Hamstring Tendon Autografts in ACL Reconstruction: A Comparative Study of 106 Patients’ Outcomes

    by Bilal Gök, Muharrem Kanar, Yılmaz Tutak

    BACKGROUND:Anterior cruciate ligament (ACL) reconstruction commonly uses a hamstring tendon autograft, but the peroneus longus tendon can also be used. This study aimed to compare outcomes of anterior cruciate ligament reconstruction in 106 patients using peroneus longus tendon and hamstring tendon autografts. MATERIAL AND METHODS:ACL repair was performed on 54 patients using a hamstring tendon autograft and 52 patients with a peroneus longus tendon autograft. Knee function was assessed using the International Knee Documentation Committee (IKDC) and Lysholm scores, while the ankle was evaluated using the American Orthopedic Foot and Ankle Score (AOFAS) and the Foot & Ankle Disability Index (FADI) scores. Donor-site morbidity and graft characteristics were compared. RESULTS:There was no difference between the 2 groups in terms of knee IKDC and Lysholm scores (p=0.49, p=0.68, respectively). The diameter of the peroneus longus tendon graft (8.56±0.93) was significantly larger than the hamstring tendon (7.44±0.6) (p<0.001). The peroneus graft harvesting time was significantly shorter (p<0.001). Thigh hypotrophy and donor-site morbidity were significantly higher in the hamstring group (p<0.001 and p=0.006). The donor ankle AOFAS score was 93.46±3.8, and the FADI score was 93.48±4.6. No morbidity associated with the peroneus longus graft was observed. CONCLUSIONS:Patients who underwent ACL reconstruction using the peroneus longus tendon experienced faster knee rehabilitation and less donor-site morbidity, such as thigh hypotrophy and knee pain. The peroneus longus tendon, with its larger diameter, fewer graft-related complications, and similar knee scores compared to the hamstring group, is considered a suitable alternative graft source.


  • Open Access

    Enhanced Outcomes and Safety of Reverse Shoulder Arthroplasty in Rotator Cuff Deficiency and Proximal Humerus Fractures: A 22-Patient Retrospective Analysis

    by Yılmaz Tutak, Bilal Gök

    Background: Reverse shoulder arthroplasty (RSA) is an accepted treatment that provides reproducible results in the treatment of rotator cuff deficiency and proximal humerus fractures. This single-center study aimed to evaluate the outcomes from reverse shoulder arthroplasty for rotator cuff & imath;nsufficiency and proximal humerus fractures in 22 patients from a single center. Material/Methods: Twenty-two patients were included in the study. The median age of the patients was 66 years (Range: 58-95). Proximal humerus fractures were diagnosed using X-ray and CT, while rotator cuff tears were diagnosed using MRI. For the assessment of joint function, the Constant-Murley score, the American Shoulder and Elbow Surgeons (ASES), and the Disabilities of Arm, Shoulder, and Hand (DASH) scores were used as patient-reported outcome measures. Kaplan-Meier analysis was conducted to evaluate implant survival. Results: The mean follow-up duration was 4.05 +/- 1.2 years. Significant improvements were observed: ASES Score: Increased from 35.8 +/- 2.8 to 81.3 +/- 5.4 (p<0.001). VAS Pain Score: Decreased from 7.3 +/- 1 to 2.9 +/- 0.9 (p<0.001). DASH Score: Improved from 66.3 +/- 4.3 to 32.5 +/- 3.6 (p<0.001). Constant-Murley Score: Increased from 48.3 +/- 3.5 to 74.6 +/- 7.7 (p<0.001). Kaplan-Meier analysis estimated implant survival at 6.7 years (95% CI, 6.3-7.2). Conclusions: When performed with appropriate indications, RSA yields positive results, as seen in the literature and our study. Interscalene block anesthesia, advancements in implant technology, and adherence to surgical procedures can reduce RSA complications and ensure its safe application.