TPTom Plovie

Tom Plovie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tom Plovie has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Computational Modeling of the Acoustic Radiation Force and Viscoelastic Displacement for Transcranial Focused Ultrasound Neuromodulation

    by Tom Plovie, Emmeric Tanghe, Thomas Tarnaud

    Objective: In transcranial ultrasound neuromodulation (TUS), simulations of the harmonic pressure are often used for treatment planning. However, other mechanisms of energy transfer, such as acoustic radiation force (ARF) and the resulting tissue displacement, are reported less frequently. Furthermore, there is limited guidance on how these mechanisms should be simulated. This study evaluates the numerical convergence and accuracy of different ARF formulations and investigates the simulation of ultrasound-induced tissue displacement in the context of TUS. Approach: Two simulations steps are used in k-Wave to first simulate the first order acoustic pressure and velocity fields. Subsequently, these fields are used to calculate the ARF using the momentum-flux density tensor, Reynold’s stress force, and attenuation force formulations. The ARF is then applied as input for a second viscoelastic simulation to estimate the tissue displacement induced by the ultrasound field. Numerical accuracy and convergence are quantified as functions of the various numerical choices and hyperparameters in the solvers. Main results: Among the investigated formulations, the attenuation-force approach proved to be the most robust and the least susceptible to numerical errors across variable medium types and transducer geometries. Within the parameter space relevant to TUS, it is a valid approximation of the momentum flux density tensor formulation. Similar tissue displacement distributions are found across the different ARF formulations. However, the accuracy of the displacement simulation decreases with increasing pulse duration. Finally, recommendations are formulated on the ARF calculation method and on the numerical hyperparameters for ARF and displacement simulations. Significance: This study offers guidelines for calculating the ARF and simulating tissue displacement. The proposed framework enables a more comprehensive characterization of ultrasound-mediated energy transfer in TUS.

  • Open Access

    Action potential threshold variability for different electrostimulation models and its potential impact on occupational exposure limit values

    by Florian Soyka, Thomas Tarnaud, Carsten Alteköster, Ruben Schoeters, Tom Plovie, Wout Joseph, Emmeric Tanghe

    Occupational exposure limit values (ELVs) for body internal electric fields can be derived from thresholds for action potential generation. These thresholds can be calculated with electrostimulation models. The spatially extended nonlinear node model (SENN) is often used to determine such thresholds. Important parameters of these models are the membrane channel dynamics describing the ionic transmembrane currents as well as the temperature at which the models operate. This work compares action potential thresholds for five different membrane channel dynamics used with the SENN model. Furthermore, two more detailed double‐cable models by Gaines et al. (MRG‐Sensory and MRG‐Motor) are also considered in this work. Thresholds calculated with the SENN model and the MRG models are compared for frequencies between 1 Hz and 100 kHz and temperatures at 22°C and 37°C. Results show that MRG thresholds are lower than SENN thresholds. Deriving alternative ELVs from these thresholds shows that the alternative ELVs can change significantly with different ion channel dynamics (up to a factor of 22). Using the double cable model could lead to approximately ten times lower alternative exposure limit values. On the contrary, using the SENN model with different membrane channel dynamics could also lead to higher alternative exposure limit values. Therefore, future exposure guidelines should take the influence of different electrostimulation models into account when deriving ELVs.


  • Nonlinearities and timescales in neural models of temporal interference stimulation

    by Tom Plovie, Ruben Schoeters, Thomas Tarnaud, Wout Joseph, Emmeric Tanghe

    In temporal interference (TI) stimulation, neuronal cells react to two interfering sinusoidal electric fields with a slightly different frequency (, in the range of about 1–4 kHz, in the range of about 1–100 Hz). It has been previously observed that for the same input intensity, the neurons do not react to a purely sinusoidal signal at or . This study seeks a better understanding of the largely unknown mechanisms underlying TI neuromodulation. To this end, single‐compartment models are used to simulate computationally the response of neurons to the sinusoidal and TI waveform. This study compares five different neuron models: Hodgkin‐Huxley (HH), Frankenhaeuser–Huxley (FH), along with leaky, exponential, and adaptive‐exponential integrate‐and‐fire (IF). It was found that IF models do not entirely reflect the experimental behavior while the HH and FH model did qualitatively replicate the observed neural responses. Changing the time constants and steady state values of the ion gates in the FH model alters the response to both the sinusoidal and TI signal, possibly reducing the firing threshold of the sinusoidal input below that of the TI input. The results show that in the modified (simplified) model, TI stimulation is not qualitatively impacted by nonlinearities in the current–voltage relation. In contrast, ion channels have a significant impact on the neuronal response. This paper offers insights into neuronal biophysics and computational models of TI stimulation.