Dinh Bao-Hung Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dinh Bao-Hung Nguyen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Huu-Phuc Kieu
Department of Electrical and Information Engineering, Seoul National University of Science and Technology (Seoul Tech), Seoul, South Korea
4 shared publications - Sewan Choi
Department of Electrical and Information Engineering, Seoul National University of Science and Technology, Seoul, South Korea
4 shared publications - Ba Phu Do
Department of Electrical and Information Engineering, Seoul National University of Science and Technology, Seoul, South Korea
3 shared publications - Million Gerado Geda
Department of Electrical and Information Engineering, Seoul National University of Science and Technology (Seoul Tech), Seoul, South Korea
2 shared publications - Huigyeong Song
Department of Electrical and Information Engineering, Seoul National University of Science and Technology (Seoul Tech), Seoul, South Korea
1 shared publication - Sunju Kim
Department of Electrical and Information Engineering, Seoul National University of Science and Technology, Seoul, South Korea
1 shared publication
Latest Publications
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
An improved transformer-grid inductor magnetic integration for single-stage on-board charger
This article proposes an improved integrated magnetic structure for the single-stage interleaved totem-pole AC-DC converter, which is applicable for on-board chargers (OBCs). The grid inductors are integrated into the high-frequency transformer, which eliminates the core and winding of grid inductors. This results in a reduction in the magnetic loss, core material volume, and total volume. The analytical comparison among three core candidates to implement the integrated magnetic structure is discussed. The four-leg integrated magnetic, whose total volume is 11% smaller than that of the prior art integration, is selected for further design. An optimized design based on the Figure of Merit (FoM) method is carried out to design the proposed magnetic. A single-phase 3.7kW single-stage OBC prototype with both discrete and integrated magnetic structures is assembled and tested. Compared to the discrete structure, the converter efficiency with the integrated one is 1% higher at light load, and 0.1% higher at full load. In addition, the integrated magnetic volume is 35% smaller than the discrete one. The designed module achieves 97.3% peak efficiency.
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
An improved transformer-grid inductor magnetic integration for single-stage on-board charger
This article proposes an improved integrated magnetic structure for the single-stage interleaved totem-pole AC-DC converter, which is applicable for on-board chargers (OBCs). The grid inductors are integrated into the high-frequency transformer, which eliminates the core and winding of grid inductors. This results in a reduction in the magnetic loss, core material volume, and total volume. The analytical comparison among three core candidates to implement the integrated magnetic structure is discussed. The four-leg integrated magnetic, whose total volume is 11% smaller than that of the prior art integration, is selected for further design. An optimized design based on the Figure of Merit (FoM) method is carried out to design the proposed magnetic. A single-phase 3.7kW single-stage OBC prototype with both discrete and integrated magnetic structures is assembled and tested. Compared to the discrete structure, the converter efficiency with the integrated one is 1% higher at light load, and 0.1% higher at full load. In addition, the integrated magnetic volume is 35% smaller than the discrete one. The designed module achieves 97.3% peak efficiency.
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 561-573
Three/Single-Phase Compatibility Single-Stage EV Charger With Six-Switch Full-Bridge Configuration
This article presents a single-stage electrolytic capacitor-less ac–dc converter designed for electric vehicle (EV) chargers, featuring a six-switch full-bridge dc side configuration with both three-phase and single-phase compatibility. The proposed topology features three interleaved totem pole modules on the ac side and a six-switch full bridge on the dc side, interconnected via a delta (Δ) transformer configuration. For three-phase grid operation, this article introduces an advanced duty cycle modulation technique to extend the zero voltage switching (ZVS) range across a wide battery voltage range and enhance the total harmonic distortion (THD) performance of the grid current under varying load conditions. An unbalanced control method is proposed to mitigate low-frequency harmonic distortion in the charging current, effectively compensating for both sag and swell conditions in the grid voltage. The integrated buck-type power decoupling circuit is introduced for single-phase grid operation to absorb the second harmonic current component and eliminate the need for external components. To validate the proposed topology, an 11 kW laboratory EV charger prototype was developed and tested, achieving a peak efficiency of 96.8% and a THD of grid current of 2.5%.
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 561-573
Three/Single-Phase Compatibility Single-Stage EV Charger With Six-Switch Full-Bridge Configuration
This article presents a single-stage electrolytic capacitor-less ac–dc converter designed for electric vehicle (EV) chargers, featuring a six-switch full-bridge dc side configuration with both three-phase and single-phase compatibility. The proposed topology features three interleaved totem pole modules on the ac side and a six-switch full bridge on the dc side, interconnected via a delta (Δ) transformer configuration. For three-phase grid operation, this article introduces an advanced duty cycle modulation technique to extend the zero voltage switching (ZVS) range across a wide battery voltage range and enhance the total harmonic distortion (THD) performance of the grid current under varying load conditions. An unbalanced control method is proposed to mitigate low-frequency harmonic distortion in the charging current, effectively compensating for both sag and swell conditions in the grid voltage. The integrated buck-type power decoupling circuit is introduced for single-phase grid operation to absorb the second harmonic current component and eliminate the need for external components. To validate the proposed topology, an 11 kW laboratory EV charger prototype was developed and tested, achieving a peak efficiency of 96.8% and a THD of grid current of 2.5%.
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (2) , 1958-1968
Improved Light-Load Efficiency Modulation for Wide Voltage Range Single-Stage AC–DC Converter
This paper introduces a light load efficient modulation strategy for single-stage AC-DC converters. The proposed modulation scheme is implemented on a modified push-pull single-stage AC-DC converter. This converter achieves a ZVS turn-on over a wide voltage range at full power with the introduced auxiliary inductor. However, single-stage converters commonly suffer from low efficiency at light loads due to hard switching and the dominance of circulating current, which causes significant power losses. To address these challenges, this work proposes a modulation strategy that uses adaptive switching frequency to improve light load efficiency. Experimental results from a 3.7 kW single-stage On-Board Charger (OBC) prototype are provided to verify the theoretical claims across various load levels. As a result, light load conversion performance including efficiency and power quality are improved. This concept is particularly important for Battery Energy Storage Systems (BESS) and photovoltaic (PV) conversion systems, where diversified load levels are common.
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (2) , 1958-1968
Improved Light-Load Efficiency Modulation for Wide Voltage Range Single-Stage AC–DC Converter
This paper introduces a light load efficient modulation strategy for single-stage AC-DC converters. The proposed modulation scheme is implemented on a modified push-pull single-stage AC-DC converter. This converter achieves a ZVS turn-on over a wide voltage range at full power with the introduced auxiliary inductor. However, single-stage converters commonly suffer from low efficiency at light loads due to hard switching and the dominance of circulating current, which causes significant power losses. To address these challenges, this work proposes a modulation strategy that uses adaptive switching frequency to improve light load efficiency. Experimental results from a 3.7 kW single-stage On-Board Charger (OBC) prototype are provided to verify the theoretical claims across various load levels. As a result, light load conversion performance including efficiency and power quality are improved. This concept is particularly important for Battery Energy Storage Systems (BESS) and photovoltaic (PV) conversion systems, where diversified load levels are common.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 13336-13347
An All-in-One Magnetic Structure for Entire ZVS Range Auxiliary Power Module in Electrical Vehicles
This article proposes an all-in-one magnetic structure that integrates a leakage inductor, two filter inductors, and a transformer in the phase shift full bridge (PSFB) current doubler converter for the auxiliary power module (APM). The proposed integration technique significantly reduces the number of magnetic components, not only achieving a 17.5% reduction in the magnetic volume and a 26% reduction in the magnetic loss but also simplifying the manufacturing processes. Considering the coupling effect in the proposed integrated structure, the zero voltage switching (ZVS) energy is increased. An optimized coupling coefficient is proposed to cover the entire ZVS range, considering the increase in RMS current associated with an elevated coupling coefficient. To validate the effectiveness of the proposed structure, a 3-kW and 200-kHz prototype APM with an input range of 360–800 V and an output voltage range of 11.5–15.3 V is built and tested. The achieved peak efficiency is 95.5%, and the power density reaches 8.4 kW/L.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 13336-13347
An All-in-One Magnetic Structure for Entire ZVS Range Auxiliary Power Module in Electrical Vehicles
This article proposes an all-in-one magnetic structure that integrates a leakage inductor, two filter inductors, and a transformer in the phase shift full bridge (PSFB) current doubler converter for the auxiliary power module (APM). The proposed integration technique significantly reduces the number of magnetic components, not only achieving a 17.5% reduction in the magnetic volume and a 26% reduction in the magnetic loss but also simplifying the manufacturing processes. Considering the coupling effect in the proposed integrated structure, the zero voltage switching (ZVS) energy is increased. An optimized coupling coefficient is proposed to cover the entire ZVS range, considering the increase in RMS current associated with an elevated coupling coefficient. To validate the effectiveness of the proposed structure, a 3-kW and 200-kHz prototype APM with an input range of 360–800 V and an output voltage range of 11.5–15.3 V is built and tested. The achieved peak efficiency is 95.5%, and the power density reaches 8.4 kW/L.