Wenhao Duan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenhao Duan has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Shubin Liu
University of Science and Technology of China
5 shared publications - Chang-Qing Feng
University of Science and Technology of China
4 shared publications Han Yi
3 shared publicationsYijia Qiu
3 shared publicationsChangqing Feng
2 shared publicationsGuohui Zhang
2 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 4139-4148
Low-Dead-Time High-Precision Wave Union FPGA-Based Time-to-Digital Converters With Event-Aggregation Encoder
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 4139-4148
Low-Dead-Time High-Precision Wave Union FPGA-Based Time-to-Digital Converters With Event-Aggregation Encoder
- 22 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2440-2449
An FPGA-Based Hybrid Wave Union Time-to-Digital Converter With Iterative Z-Type Code Calibration Algorithm
A novel FPGA-based multi-measurement scheme Time-to-Digital Converter (TDC) architecture, termed Hybrid Wave Union (HWU), is proposed. By integrating the advantages of the Wave Union A and Wave Union B methods, the designed TDC launches a ripple with multiple transitions along the tapped delay line (TDL) and samples it with a D flip-flop (DFF) array across consecutive system clock cycles upon the arrival of a rising edge, yielding two complementary snapshots. Each snapshot is encoded into fine timestamps through a pipeline encoder, and the resulting timestamp pairs are processed by an iterative Z-type calibration algorithm that reconstructs accurate delay intervals without requiring any predefined knowledge of the relative ordering of delay durations. The design is implemented on a Xilinx Kintex-7 FPGA, with a measured on-chip power consumption of 42 mW per channel, including 6 mW for the TDL and DFF bank, 31 mW for the encoder and packetization logic, and 5 mW shared across all TDC channels for the coarse time counter. Experimental results demonstrate an average RMS timing precision of 4.4 ps and a dead time of only three clock cycles—two for snapshot acquisition and one for TDL reset—significantly shorter than that of conventional Wave Union B TDCs. Compared to traditional TDL TDC architectures, the proposed HWU TDC achieves high timing precision, low resource utilization, and energy-efficient operation, making it well suited for multi-channel, high-precision applications in modern high-energy physics experiments.
- 22 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2440-2449
An FPGA-Based Hybrid Wave Union Time-to-Digital Converter With Iterative Z-Type Code Calibration Algorithm
A novel FPGA-based multi-measurement scheme Time-to-Digital Converter (TDC) architecture, termed Hybrid Wave Union (HWU), is proposed. By integrating the advantages of the Wave Union A and Wave Union B methods, the designed TDC launches a ripple with multiple transitions along the tapped delay line (TDL) and samples it with a D flip-flop (DFF) array across consecutive system clock cycles upon the arrival of a rising edge, yielding two complementary snapshots. Each snapshot is encoded into fine timestamps through a pipeline encoder, and the resulting timestamp pairs are processed by an iterative Z-type calibration algorithm that reconstructs accurate delay intervals without requiring any predefined knowledge of the relative ordering of delay durations. The design is implemented on a Xilinx Kintex-7 FPGA, with a measured on-chip power consumption of 42 mW per channel, including 6 mW for the TDL and DFF bank, 31 mW for the encoder and packetization logic, and 5 mW shared across all TDC channels for the coarse time counter. Experimental results demonstrate an average RMS timing precision of 4.4 ps and a dead time of only three clock cycles—two for snapshot acquisition and one for TDL reset—significantly shorter than that of conventional Wave Union B TDCs. Compared to traditional TDL TDC architectures, the proposed HWU TDC achieves high timing precision, low resource utilization, and energy-efficient operation, making it well suited for multi-channel, high-precision applications in modern high-energy physics experiments.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (3) , 695-705
Readout Electronics for a Prototype Neutron Resonance Imaging System With 10 B-Doped MCP Detector
Neutron Resonance Imaging (NRI) is a non-destructive material analysis method utilizing energy-dependent resonance absorption. The key challenge for its readout electronics is to operate at instantaneous event rates exceeding MHz while achieving low noise and high time resolution. In this paper, we present a design of readout electronics for a prototype NRI system with a 10B-doped microchannel plate (MCP). The prototype has 256 channels for charge and time-of-flight (TOF) measurement. The triggerless and the self-trigger are employed separately in high and low event rate time periods. During the high-event-rate period, with an event rate exceeding 200 kHz, the electronics actively creates two long time windows to perform complete waveform digitization. Then, the electronics automatically switches to the self-trigger in the low-event-rate period. The complete waveform can be stored and read out during the low-event-rate period. This design enables no dead time in the high-event-rate period and reduces the amount of data in the low-event-rate period. Test results show that the minimum interval between two triggers is 1.7 μs during the low-event-rate period, corresponding to a maximum instantaneous trigger rate of up to 580 kHz. The accuracy of the neutron TOF is better than 3 ns. The RMS of the noise is less than 0.3 fC. Finally, the readout electronics was assembled with the prototype and tested on the neutron beam at CSNS Back-n. The samples made of different metals were successfully imaged.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (3) , 695-705
Readout Electronics for a Prototype Neutron Resonance Imaging System With 10 B-Doped MCP Detector
Neutron Resonance Imaging (NRI) is a non-destructive material analysis method utilizing energy-dependent resonance absorption. The key challenge for its readout electronics is to operate at instantaneous event rates exceeding MHz while achieving low noise and high time resolution. In this paper, we present a design of readout electronics for a prototype NRI system with a 10B-doped microchannel plate (MCP). The prototype has 256 channels for charge and time-of-flight (TOF) measurement. The triggerless and the self-trigger are employed separately in high and low event rate time periods. During the high-event-rate period, with an event rate exceeding 200 kHz, the electronics actively creates two long time windows to perform complete waveform digitization. Then, the electronics automatically switches to the self-trigger in the low-event-rate period. The complete waveform can be stored and read out during the low-event-rate period. This design enables no dead time in the high-event-rate period and reduces the amount of data in the low-event-rate period. Test results show that the minimum interval between two triggers is 1.7 μs during the low-event-rate period, corresponding to a maximum instantaneous trigger rate of up to 580 kHz. The accuracy of the neutron TOF is better than 3 ns. The RMS of the noise is less than 0.3 fC. Finally, the readout electronics was assembled with the prototype and tested on the neutron beam at CSNS Back-n. The samples made of different metals were successfully imaged.
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (12) , 2545-2553
Measurement of Neutron-Induced Single-Event Upset Cross Section of UltraScale Kintex FPGA Using Time-of-Flight Technique
The correlation between neutron energy and neutron-induced Soft Error Rate (SER) is crucial for estimating the impact on electronic devices fabricated using Complementary Metal-Oxide-Semiconductor (CMOS) technology in diverse neutron environments, including those found in high-energy physics experiments, aviation settings, etc. This paper presents an investigation conducted independently at the China Spallation Neutron Source (CSNS) using the Back-n white neutron source and Atmospheric Neutron Irradiation Spectrometer (ANIS) neutron source to directly measure Single Event Upset (SEU) effects of the Configuration Random Access Memory (CRAM) and Block Random Access Memory (BRAM) in 20 nm CMOS technology based UltraScale Kintex FPGA. By recording the frequency of SEU events and the time of flight (TOF), SEU cross-sections can be calculated for different energies. Experiment in-situ indicates a coherent alignment of different outcomes under neutron irradiation from Back-n and ANIS, despite their different neutron energy spectra. The SEU threshold energy is estimated to be 0.69 ± 0.076 MeV for CRAM, and 0.80 ± 0.013 MeV for BRAM. The measured cross-sections can reach saturation of 6.9 × 10 -15 cm 2 /bit and 1.6 × 10 -14 cm 2 /bit for CRAM and BRAM, respectively while the neutron energy is about 20 MeV.
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (12) , 2545-2553
Measurement of Neutron-Induced Single-Event Upset Cross Section of UltraScale Kintex FPGA Using Time-of-Flight Technique
The correlation between neutron energy and neutron-induced Soft Error Rate (SER) is crucial for estimating the impact on electronic devices fabricated using Complementary Metal-Oxide-Semiconductor (CMOS) technology in diverse neutron environments, including those found in high-energy physics experiments, aviation settings, etc. This paper presents an investigation conducted independently at the China Spallation Neutron Source (CSNS) using the Back-n white neutron source and Atmospheric Neutron Irradiation Spectrometer (ANIS) neutron source to directly measure Single Event Upset (SEU) effects of the Configuration Random Access Memory (CRAM) and Block Random Access Memory (BRAM) in 20 nm CMOS technology based UltraScale Kintex FPGA. By recording the frequency of SEU events and the time of flight (TOF), SEU cross-sections can be calculated for different energies. Experiment in-situ indicates a coherent alignment of different outcomes under neutron irradiation from Back-n and ANIS, despite their different neutron energy spectra. The SEU threshold energy is estimated to be 0.69 ± 0.076 MeV for CRAM, and 0.80 ± 0.013 MeV for BRAM. The measured cross-sections can reach saturation of 6.9 × 10 -15 cm 2 /bit and 1.6 × 10 -14 cm 2 /bit for CRAM and BRAM, respectively while the neutron energy is about 20 MeV.
- 3 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 705-712
An FPGA-Based High-Precision Pulsewidth Measurement Time-to-Digital Converter With Dual-TDL Multiplexer Encoder
High precision Time-to-Digital Converters (TDCs) play a pivotal role in contemporary particle physics experiments where the measurement of time-over-threshold (TOT) of signal pulses is essential. The stringent demand for picosecond resolution of pulse widths ranging from several hundred picoseconds to hundreds of nanoseconds, coupled with the high requirements for measurement throughput, presents formidable challenges in the design and optimization of pulse width measurement TDCs. This article introduces a novel dual tapped delay lines (TDL) TDC along with a dual-TDL multiplexer encoder to measure the arrival time and TOT time of signal pulses simultaneously in high precision. Utilizing the aforementioned architecture, a series of dual-TDL TDCs with 2,4,6,8-edge multiple measurements scheme capable of measuring the arrival time and TOT time simultaneously at 250 Msps are implemented in a Xilinx Kintex-7 FPGA. The minimum measurable pulse width is determined by the upper limit speed of the FPGA transmitting port and the characteristics of the high-speed comparator, test as 520 ps in our implementation. With pulse widths ranging from 520 ps to 1000 ns, the average TOT measurement RMS precision of the series TDCs is evaluated to be below 5.5 ps, which can be improved by the increasing times of multiple measurements. Specifically, the 8-edge dual-TDL TDC can achieve a precision as low as 3.4 ps. Furthermore The proposed dual-TDL TDC boasts resource efficiency and cost-effectiveness features, making it well suited for particle physics experiments that demand multi-channel capability at an affordable price, along with high performance.
- 3 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 705-712
An FPGA-Based High-Precision Pulsewidth Measurement Time-to-Digital Converter With Dual-TDL Multiplexer Encoder
High precision Time-to-Digital Converters (TDCs) play a pivotal role in contemporary particle physics experiments where the measurement of time-over-threshold (TOT) of signal pulses is essential. The stringent demand for picosecond resolution of pulse widths ranging from several hundred picoseconds to hundreds of nanoseconds, coupled with the high requirements for measurement throughput, presents formidable challenges in the design and optimization of pulse width measurement TDCs. This article introduces a novel dual tapped delay lines (TDL) TDC along with a dual-TDL multiplexer encoder to measure the arrival time and TOT time of signal pulses simultaneously in high precision. Utilizing the aforementioned architecture, a series of dual-TDL TDCs with 2,4,6,8-edge multiple measurements scheme capable of measuring the arrival time and TOT time simultaneously at 250 Msps are implemented in a Xilinx Kintex-7 FPGA. The minimum measurable pulse width is determined by the upper limit speed of the FPGA transmitting port and the characteristics of the high-speed comparator, test as 520 ps in our implementation. With pulse widths ranging from 520 ps to 1000 ns, the average TOT measurement RMS precision of the series TDCs is evaluated to be below 5.5 ps, which can be improved by the increasing times of multiple measurements. Specifically, the 8-edge dual-TDL TDC can achieve a precision as low as 3.4 ps. Furthermore The proposed dual-TDL TDC boasts resource efficiency and cost-effectiveness features, making it well suited for particle physics experiments that demand multi-channel capability at an affordable price, along with high performance.