Abdelmoumene Hechifa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdelmoumene Hechifa has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Abdelaziz Lakehal
University of Souk Ahras
3 shared publications - Chouaib Labiod
Department of Mechanical Engineering, University of El Oued, El Oued, Algeria
2 shared publications - Ciptian Weried Priananda
Department of Electrical Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
2 shared publications - Diaa-Eldin A. Mansour
Electrical Power Engineering Department, Faculty of Engineering, Egypt-Japan University of Science and Technology (E-JUST), Alexandria 21934, Egypt
2 shared publications - Hazlee Azil Illias
Universiti Malaya
2 shared publications Abdellatif K. Rashed
Université de Pau et des Pays de l'Adour
1 shared publication
Latest Publications
- 27 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Enhanced Circle Method for Discriminating Incipient Faults in Power Transformers Using Dissolved Gas Analysis
Power transformers are essential components in electrical power systems, ensuring the continuous transmission and distribution of electricity. Dissolved Gas Analysis (DGA) has become a widely accepted method for monitoring the condition of transformers and detecting incipient faults. Among the various DGA methods, graphical techniques have gained significant popularity in recent years. In this study, an Improved Circle Method is proposed as an enhanced extension of the Circle 1 and Circle 2 methods to address the limitations of traditional DGA methods in distinguishing overlapping fault types. The method employs a sigmoid activation function to control the convergence and divergence distances between fault samples, significantly improving the separation of electrical and thermal faults. By utilizing Gray Wolf Optimization (GWO), optimal angles are determined for the best fault separation. Experimental validation using the IEC TC10 database demonstrated that the Improved Circle Method achieves an overall accuracy of 79.49%, which can be considered an improvement over both Circle 1 and Circle 2 methods. The results confirm that the proposed method serves as a reliable alternative to other conventional graphical techniques.
- 27 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Enhanced Circle Method for Discriminating Incipient Faults in Power Transformers Using Dissolved Gas Analysis
Power transformers are essential components in electrical power systems, ensuring the continuous transmission and distribution of electricity. Dissolved Gas Analysis (DGA) has become a widely accepted method for monitoring the condition of transformers and detecting incipient faults. Among the various DGA methods, graphical techniques have gained significant popularity in recent years. In this study, an Improved Circle Method is proposed as an enhanced extension of the Circle 1 and Circle 2 methods to address the limitations of traditional DGA methods in distinguishing overlapping fault types. The method employs a sigmoid activation function to control the convergence and divergence distances between fault samples, significantly improving the separation of electrical and thermal faults. By utilizing Gray Wolf Optimization (GWO), optimal angles are determined for the best fault separation. Experimental validation using the IEC TC10 database demonstrated that the Improved Circle Method achieves an overall accuracy of 79.49%, which can be considered an improvement over both Circle 1 and Circle 2 methods. The results confirm that the proposed method serves as a reliable alternative to other conventional graphical techniques.
- 24 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Detection Transformer-based Deep Learning for Multisource Partial Discharge Recognition in High-Voltage Rotating Machine Insulation
Partial discharge (PD) is a critical early indicator of insulation degradation in high-voltage rotating machines. Minor undetected defects during manufacturing, combined with operational stresses, often trigger PD activity that accelerates insulation aging. The elongated structure of stator windings increases the possibility of multiple PD sources occurring simultaneously, each generating a distinct Phase-Resolved Partial Discharge (PRPD) pattern. However, when multiple defects are present, these patterns overlap, leading to challenges such as occlusion, nesting, and the Multisource Partial Discharge Horizontal Flattening Effect (MPD-HFE), where weaker discharges are visually suppressed, which challenge conventional classifiers due to signal occlusion and distortion effects. This work proposes a Detection Transformer (DETR)–based deep learning approach, enhanced with flattening augmentation to replicate dominant pattern distortions. The method enables simultaneous detection and classification of overlapping PRPD patterns by utilizing DETR’s global self-attention to mitigate discharge dominance and feature suppression. Evaluated on a multisource PRPD dataset comprising six defect types and 63 class combinations, the proposed model achieved 97.4% accuracy on single-source PD defects and 90.9% on multisource cases, with an overall accuracy of 93.7%.
- 24 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Detection Transformer-based Deep Learning for Multisource Partial Discharge Recognition in High-Voltage Rotating Machine Insulation
Partial discharge (PD) is a critical early indicator of insulation degradation in high-voltage rotating machines. Minor undetected defects during manufacturing, combined with operational stresses, often trigger PD activity that accelerates insulation aging. The elongated structure of stator windings increases the possibility of multiple PD sources occurring simultaneously, each generating a distinct Phase-Resolved Partial Discharge (PRPD) pattern. However, when multiple defects are present, these patterns overlap, leading to challenges such as occlusion, nesting, and the Multisource Partial Discharge Horizontal Flattening Effect (MPD-HFE), where weaker discharges are visually suppressed, which challenge conventional classifiers due to signal occlusion and distortion effects. This work proposes a Detection Transformer (DETR)–based deep learning approach, enhanced with flattening augmentation to replicate dominant pattern distortions. The method enables simultaneous detection and classification of overlapping PRPD patterns by utilizing DETR’s global self-attention to mitigate discharge dominance and feature suppression. Evaluated on a multisource PRPD dataset comprising six defect types and 63 class combinations, the proposed model achieved 97.4% accuracy on single-source PD defects and 90.9% on multisource cases, with an overall accuracy of 93.7%.
- 3 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (6) , 3186-3198
A Novel Graphical Method for Interpretating Dissolved Gases and Fault Diagnosis in Power Transformer Based on Dynamique Axes in Circular Form
Dissolved Gas Analysis (DGA) in oil is one of the most common and reliable techniques for diagnosing and early detection of incipient faults in oil-immersed transformers. However, conventional methods often encounter conflicts and challenges in accurately interpreting DGA results. Addressing this, two novel graphical methods, Circle Method 1 and Circle Method 2, are proposed, represented by circles with movable axes at variable angles. These methods innovatively base their analysis on the convergence of samples with similar characteristics around their centers and the spacing of these centers for samples with differing characteristics. The primary purpose of these methods is to distinguish between different overlapping faults. To achieve this, advanced metaheuristic algorithms are employed to determine the optimal angles that yield the best distribution of samples. Utilizing insights from previous DGA methods and field experiences, initial fault zones within Circle Methods 1 and 2 are estimated, and precise boundaries between fault zones are established based on practical DGA data collected from multiple sources. Evaluation using IEC TC10 database of fault cases demonstrates that Circle Methods 1 and 2 exhibit superior diagnostic accuracy compared to existing methods, including the Mansour Pentagon, the Duval Pentagon, the Gouda Triangle, and the Cartesian Graphical Method. This innovation significantly enhances the interpretative capabilities of DGA, offering a more reliable tool for fault diagnosis in oil-immersed transformers.
- 3 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (6) , 3186-3198
A Novel Graphical Method for Interpretating Dissolved Gases and Fault Diagnosis in Power Transformer Based on Dynamique Axes in Circular Form
Dissolved Gas Analysis (DGA) in oil is one of the most common and reliable techniques for diagnosing and early detection of incipient faults in oil-immersed transformers. However, conventional methods often encounter conflicts and challenges in accurately interpreting DGA results. Addressing this, two novel graphical methods, Circle Method 1 and Circle Method 2, are proposed, represented by circles with movable axes at variable angles. These methods innovatively base their analysis on the convergence of samples with similar characteristics around their centers and the spacing of these centers for samples with differing characteristics. The primary purpose of these methods is to distinguish between different overlapping faults. To achieve this, advanced metaheuristic algorithms are employed to determine the optimal angles that yield the best distribution of samples. Utilizing insights from previous DGA methods and field experiences, initial fault zones within Circle Methods 1 and 2 are estimated, and precise boundaries between fault zones are established based on practical DGA data collected from multiple sources. Evaluation using IEC TC10 database of fault cases demonstrates that Circle Methods 1 and 2 exhibit superior diagnostic accuracy compared to existing methods, including the Mansour Pentagon, the Duval Pentagon, the Gouda Triangle, and the Cartesian Graphical Method. This innovation significantly enhances the interpretative capabilities of DGA, offering a more reliable tool for fault diagnosis in oil-immersed transformers.