CPCiptian Weried Priananda

Ciptian Weried Priananda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ciptian Weried Priananda has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Adaptive Voltage-Based Clustering and Reconfiguration Strategyfor Photovoltaic Farms Under Partial Shading Conditions

    by Fauzi Imaduddin Adhim, Ciptian Weried Weried Priananda, Lucky Putri Rahayu, Abdelmoumene Hechifa, Hazlee Illias

    Partial shading conditions (PSCs) significantly reduce the power extraction capability of photovoltaic (PV) arrays by introducing electrical mismatch among PV strings and creating multiple local maxima in the power--voltage characteristic. While numerous global maximum power point tracking (GMPPT) algorithms have been proposed to identify the global operating point, most approaches focus exclusively on converter-level optimization without mitigating the mismatch losses inherent in PV array configuration. This paper proposes an adaptive voltage-based clustering and relay-matrix reconfiguration framework to improve the energy-harvesting capability of PV arrays operating under PSCs. The proposed method continuously measures the terminal voltage of each PV string, automatically groups strings with similar electrical operating conditions into voltage clusters, and dynamically reconfigures the array through a relay matrix. Each cluster is connected to a dedicated DC-DC converter and independently controlled using a Modified Perturb and Observe (P&O) algorithm. The proposed framework is evaluated using a PV array consisting of six strings, each with five series-connected PV modules, under a uniform irradiance and seven representative PSC scenarios. Simulation results demonstrate that the proposed framework consistently outperforms conventional P&O, Modified P&O, Particle Swarm Optimization (PSO), and Firefly Algorithm (FA) MPPT methods, achieving an average power extraction ratio of 92.17\% of the theoretically available PV power while improving the recoverable power by an average of 29.47\% compared with the original PV array configuration under PSCs. These results demonstrate that the proposed method effectively reduces electrical mismatch prior to MPPT, providing a practical and scalable framework for enhancing PV array performance under PSCs.

  • Improved Classification of Partial Discharge in Rotating Machines via Feature Extraction, Selection and Integrated Random Forest

    by Abdelmoumene Hechifa, Ciptian Weried Priananda, Hazlee Azil Bin Illias, Abdelaziz Lakehal, Abdellatif K. Rashed, Diaa-Eldin A. Mansour

  • Time-Frequency Scalograms of Deep Learning-Based Partial Discharge Classification in Air-Insulated Switchgear Using UHF Detection

    by Hakima Cherif, Ciptian Weried Priananda, Hazlee Azil Illias, Chan Jun Qiang, Wong Jee Keen Raymond, Ali Chemsa

    Partial discharge (PD) monitoring is essential for the condition assessment of air-insulated switchgear (AIS). This paper presents an experimental framework that acquires ultra-high-frequency (UHF) PD signals corresponding to four representative insulation defects: corona, surface, floating electrode, and triple junction. The collected signals are transformed into time–frequency representations using the Continuous Wavelet Transform (CWT) and the Wavelet Synchrosqueezing Transform (WSST) with two analytic mother wavelets, namely Amor and Bump. The resulting scalograms are employed as inputs to a convolutional neural network (CNN) for training and are evaluated using 5-fold cross-validation for PD classification. Comparative results show that WSST consistently improves class separability over CWT across both wavelets, where the WSST-Amor configuration achieves the best overall accuracy of 98.02%, surpassing CWT-Amor, WSST-Bump, and CWT-Bump. Compared to traditional phase-resolved partial discharge (PRPD) approaches, which require larger datasets and more complex acquisition setups, the proposed scalogram-based method provides rich feature representations using fewer signals, offering a more practical and efficient pathway for automated PD diagnosis in AIS.


  • Open Access

    A Robust Scalogram-Based Framework for Partial Discharge Diagnosis in Rotating Machine Insulation Using a Hybrid CNN-SE-Transformer Model

    by Ciptian Weried Weried Priananda, Hazlee Illias, Wong Jee Keen Raymond, Jun Qiang Chan, Hakima Cherif, I. Made Yulistya Negara

    Partial discharge (PD) analysis is essential for assessing the insulation condition of high-voltage rotating machines, as undetected defects may lead to severe failures and operational downtime. However, existing PD diagnostic approaches often rely on phase-resolved measurements or lack robustness under noisy conditions, limiting their applicability in practical environments. This study proposes a robust diagnostic framework integrating waveform-based PD acquisition, wavelet-based scalogram representation, and a hybrid CNN-SE-Transformer deep learning architecture. The proposed approach transforms non-stationary PD signals into time-frequency scalograms using both the Discrete Wavelet Transform (DWT) and Continuous Wavelet Transform (CWT), enabling enhanced feature representation. The hybrid model combines CNN-based local feature extraction, squeeze-and-excitation attention, and transformer-based global feature modeling. The framework is evaluated using a balanced dataset of six PD defect types under both clean and noisy conditions with a modified five-fold cross-validation strategy. Under clean conditions, the proposed model achieves a maximum classification accuracy of 97.25\% using CWT scalograms, outperforming conventional CNN and CNN-SE models. Robustness evaluation under various artificial noise scenarios further demonstrates that the proposed method maintains stable performance, with CWT-based representations providing superior resilience compared to raw signals and DWT scalograms. Compared to conventional PRPD approaches requiring phase synchronization and specialized instrumentation, the proposed framework offers a simpler yet effective alternative for practical PD-based condition monitoring in high-voltage rotating machines.

  • Detection Transformer-based Deep Learning for Multisource Partial Discharge Recognition in High-Voltage Rotating Machine Insulation

    by Ciptian Weried Priananda, Hazlee Azil Illias, Wong Jee Keen Raymond, Abdelmoumene Hechifa, I Made Yulistya Negara

    Partial discharge (PD) is a critical early indicator of insulation degradation in high-voltage rotating machines. Minor undetected defects during manufacturing, combined with operational stresses, often trigger PD activity that accelerates insulation aging. The elongated structure of stator windings increases the possibility of multiple PD sources occurring simultaneously, each generating a distinct Phase-Resolved Partial Discharge (PRPD) pattern. However, when multiple defects are present, these patterns overlap, leading to challenges such as occlusion, nesting, and the Multisource Partial Discharge Horizontal Flattening Effect (MPD-HFE), where weaker discharges are visually suppressed, which challenge conventional classifiers due to signal occlusion and distortion effects. This work proposes a Detection Transformer (DETR)–based deep learning approach, enhanced with flattening augmentation to replicate dominant pattern distortions. The method enables simultaneous detection and classification of overlapping PRPD patterns by utilizing DETR’s global self-attention to mitigate discharge dominance and feature suppression. Evaluated on a multisource PRPD dataset comprising six defect types and 63 class combinations, the proposed model achieved 97.4% accuracy on single-source PD defects and 90.9% on multisource cases, with an overall accuracy of 93.7%.


  • Hybrid Deep Learning Models for Enhanced Classification of Phase-Resolved Partial Discharge Patterns From High-Voltage Rotating Machine Insulation

    by Ciptian Weried Priananda, Hazlee Azil Illias, Wong Jee Keen Raymond, I. Made Yulistiya Negara

    Partial discharge (PD) monitoring plays a crucial role in identifying insulation defects in high-voltage rotating machinery, where accurate classification is essential for improving the reliability and efficiency of condition-based maintenance (CBM). This work proposes hybrid Convolutional Neural Network (CNN) models to classify PRPD patterns from six different defects in a rotating machine insulation. Various hybrid models were evaluated by integrating CNN with machine learning algorithms, which include Support Vector Machines (SVM), k-Nearest Neighbors (KNN), Logistic Regression (LR), Decision Trees (DT), Random Forests (RF), and Naive Bayes (NB). The results reveal that all proposed hybrid models consistently outperform CNN in terms of computational efficiency, by achieving an average accuracy of 94.87% across all models using two optimizers, ADAM and SGDM. Notably, CNN-RF and CNN-KNN models achieve the best performance, with an accuracy exceeding 96% with lower computational time compared to CNN, which only achieves 94.44% accuracy. Thus, this work provides valuable insight into enhancing PRPD classification with lower computational cost while increasing the classification accuracy of PRPD patterns from rotating machine insulation.