MBMarta Irene Bracco

Marta Irene Bracco

*This is an algorithmically generated author record based on publicly available information.

Marta Irene Bracco has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correlations between compartmental and areal BMD at the proximal femur: a paired comparison of QCT and 3D-DXA

    by Marta Irene Bracco, Dennis Black, Jorge Malouf, Asier Muñoz, Ludovic Humbert

    Trabecular volumetric BMD (Tb.vBMD) and cortical surface BMD (Ct.sBMD) derived from three-dimensional modeling of hip DXA scans (3D-DXA) correlate strongly with areal BMD (aBMD). Such correlations have been interpreted as indicating a substantial overlap between 3D-DXA parameters and the information captured by aBMD. We investigated whether correlations of this magnitude are specific to DXA-based modeling by comparing 3D-DXA with quantitative computed tomography (QCT) in the same subjects. Two cohorts with paired hip DXA and QCT were analyzed: 37 Spanish adults and 128 postmenopausal women with osteoporosis from the United States (PaTH cohort), which had lower variability in age and bone density. Pearson correlations were computed between Ct.sBMD, Tb.vBMD, and aBMD for both imaging modalities, and between QCT- and 3D-DXA-derived parameters before and after adjustment for aBMD. QCT-derived and 3D-DXA-derived compartmental parameters correlated similarly with aBMD and with each other within each cohort (R=0.84–0.96 in the Spanish cohort, 0.44–0.82 in PaTH), with markedly weaker correlations in the narrower-range PaTH cohort across both modalities. QCT–3D-DXA correlations were 0.82–0.97 and remained significant after adjustment for aBMD (partial R=0.65–0.84, all p<0.001). Strong correlations with aBMD are observed for both QCT and 3D-DXA and vary with the population studied. Thus, strong correlations with aBMD should not, by themselves, be interpreted as evidence that 3D-DXA merely reproduces aBMD or that these correlations arise from the DXA-based modeling approach. 3D-DXA parameters remained substantially correlated with QCT-derived compartmental BMD after adjustment for aBMD, suggesting that their associations with compartment-specific bone density extend beyond the information captured by standard DXA.

  • 3D–DXA cortical and trabecular parameters: agreement between hologic densitometers in clinical practice

    by Marta I Bracco, Jorge Malouf, Laurent Maïmoun, Xavier Nogues, Jean Paul Roux, François DuBoeuf, Ludovic Humbert

  • Open Access

    Validation of Automated Strain Calculation Initialised by Deep Learning Segmentation for Abdominal Aortic Aneurysm Ultrasound

    by Ulver Spangsberg Rouw, Marta Irene Bracco, Stéphane Avril, Laurence Rouet, Andreas Kryger Jensen, Jonas Peter Eiberg

  • Validation of 3D-DXA-derived proximal femur measurements against QCT across international clinical cohorts

    by Marta I. Bracco, Dennis M. Black, Teruki Sone, Luis del Rio, Silvana de Gregorio, Jorge Malouf, Ludovic Humbert


  • Open Access

    Validation of 3D-DXA–Derived Proximal Femur Measurements Against QCT Across International Clinical Cohorts

    by Marta I. Bracco, Dennis M. Black, Teruki Sone, Luis del Rio, Silvana de Gregorio, Jorge Malouf, Ludovic Humbert

    Three-dimensional dual-energy X-ray absorptiometry (3D-DXA) reconstructs proximal femur models from standard scans to estimate cortical and trabecular bone parameters. The aim of this study was to evaluate 3D-DXA against quantitative computed tomography (QCT) across independent international cohorts. The study included 537 subjects from four cohorts: an adult population from Spain, a postmenopausal female population from the United States, an osteoarthrosis population and a young population, both from Japan. Subjects underwent both 3D-DXA and QCT imaging. Accuracy was assessed using linear regression and Bland-Altman analysis to evaluate systematic and random errors. 3D-DXA parameters strongly correlated with QCT across all datasets, with correlation coefficients between 0.82 and 0.97. Random errors were consistent across cohorts and ranged between 16.55 and 19.91 mg/cm 3 for integral volumetric bone mineral density (vBMD), between 13.52 and 18.47 mg/cm 3 for trabecular vBMD, and between 9.13 and 11.37 mg/cm 2 for cortical surface bone mineral density (sBMD). Systematic errors ranged between -14.84 and 4.50 mg/cm 3 for integral vBMD, between -8.31 and 14.41 mg/cm 3 for trabecular vBMD, and between -5.58 and 3.21 mg/cm 2 for cortical sBMD. The variations in systematic errors were likely attributable to differences in QCT acquisition protocols. Overall, these results demonstrate consistent agreement between 3D-DXA and QCT across sex, age, ethnicity, geographic regions, and clinical profiles. Taken together, these findings support the use of 3D-DXA as an accurate, non-invasive, and clinically accessible technology for advanced assessment of the cortical and trabecular compartments of the proximal femur.

  • Open Access

    Ultrasound Strain Patterns are Associated with Abdominal Aortic Aneurysm Growth

    by Ulver Spangsberg Rouw, Marta Irene Bracco, Stéphane Avril, Laurence Rouet, Magdalena Broda, Julie Krogh Pedersen, Andreas Kryger Jensen, Jonas Peter Eiberg, Alexander Zielinski, Kim Kargaard Bredahl, et al.


  • Open Access

    Age-related Reference Data for Cortical and Trabecular 3D-DXA Parameters: the SEIOMM-3D-DXA Project

    by Enrique Casado, Silvana Di Gregorio, Carmen Valero, Jesus Gonzalez-Macias, Jose Manuel Olmos, Rosa Maria Arboiro-Pinel, Manuel Diaz-Curiel, Maria Angeles Vazquez-Gamez, Maria Giner, Maria Jose Montoya-Garcia, et al.

    Purpose: Osteoporosis and associated hip fractures are a major public health concern. Dualenergy X-ray Absorptiometry (DXA) remains the diagnostic gold standard, but its areal (a) bone mineral density (BMD) measurements have limited sensitivity, as many fractures occur at T-scores above −2.5. Three-dimensional (3D) DXA provides compartment-specific volumetric parameters of the hip, potentially improving osteoporosis management. This study aimed to establish reference data for 3D-DXA parameters to improve osteoporosis management and investigate potential compartmental imbalances at the hip. Method: This multicenter, cross-sectional, population-based observational study (SEIOMM-3D-DXA project), supported by the Spanish Society for Bone and Mineral Metabolism (SEIOMM), analyzed hip DXA scans from 1366 Spanish men and women across six centers. 3D-DXA analyses were conducted using the 3D-Shaper software (3D-Shaper Medical, Barcelona, Spain), producing estimates of trabecular volumetric (v) BMD and cortical surface (s) BMD. Age- and sex-specific reference curves were generated using the LMS method, and thresholds were established based on regression with T-score values. Moreover, trabecular vBMD and cortical sBMD Z-scores were calculated to evaluate potential compartmental imbalances. Results: The derived aBMD curves closely aligned with the NHANES III Caucasian reference. Sex-specific thresholds for trabecular vBMD and cortical sBMD were established for patient stratification. Z-score comparisons revealed significant discrepancies between trabecular and cortical compartments in 52.0% of females and 48.7% of males, underlining the importance of compartment-specific bone assessment. Conclusions: This study establishes reference curves for clinical interpretation of 3D-DXA parameters and demonstrates the potential of 3D-DXA to capture compartmental imbalances at the hip. Mini In this study, hip scans from over a thousand men and women in Spain were analyzed to create normative reference values for 3D-DXA parameters. These results can help doctors better stratify people based on the status of each part of the bone and improve the management of osteoporosis.


  • Open Access

    Aortic Wall Biomechanical Assessment Depends on Ultrasound Probe Pressure: In-Vivo and In-Silico Insights

    by Marta I. Bracco, Jonas P. Eiberg, Ulver S. Lorenzen, Stéphane Avril, Laurence Rouet

    Objective: Ultrasound-based aortic stiffness estimation has the potential to improve the diagnosis and prognosis of patients with abdominal aortic aneurysms (AAA), as a complement to routinely used diameter surveillance. However, existing methods have shown limited reproducibility, possibly influenced by the unknown effects of the highly variable ultrasound probe pressure. This proof-of-concept study addressed this gap by analyzing time-resolved ultrasound sequences from AAA patients. Methods: Two-dimensional ultrasound sequences were acquired from 10 AAA patients, applying light and firm probe pressure. Diameter variations and stiffness were evaluated and compared. An in-silico simulation was performed to support the in-vivo observations. Results: Measured stiffness decreased with an increased probe pressure. Specifically, in the most responsive patient group, the cyclic diameter variation between diastole and systole changed from 1% at light probe pressure to 5% at firm probe pressure, and the estimated stiffness decreased by a factor of 6.3. Another group of patients showed a marginal increase in the diameter variations and a smaller decrease in stiffness (factor of 1.5) when transitioning from light to firm probe pressure. These two behaviors were reproduced via numerical simulations, showing that the different responses to probe pressure depend on the stress-strain relationship of the wall material. Conclusion: Varying the ultrasound probe pressure can alter the in-vivo mechanics of AAAs. Significance: This proof-of-concept study suggests potential implications for AAA mechanical characterization via ultrasound imaging


  • Open Access

    Ultrasound Probe Pressure Affects Aortic Wall Stiffness: A Patient-Specific Computational Study in Abdominal Aortic Aneurysms

    by Marta Irene Bracco, Ali Akbar Karkhaneh Yousefi, Laurence Rouet, Stéphane Avril

    Purpose: Ultrasound imaging is key in the management of patients with an abdominal aortic aneurysm (AAA). It was recently shown that the cyclic diameter variations between diastole and systole, which can be quantified with US imaging, increase significantly with the strength of the applied probe pressure on the patient’s abdomen. The goal of this study is to investigate this effect more thoroughly. Methods: With finite-element modeling, pulsatile blood pressure and probe pressure are simulated in three patient-specific geometries. Two distinct models for the aortic wall were simulated: a nonlinear hyperelastic and a linear elastic model. In addition, varying stiffness was considered for the surrounding tissues. The effect of light, moderate, and firm probe pressure was quantified on the stresses and strains in the aortic wall, and on two in vivo stiffness measures. In addition, the Elasticity Loss Index was proposed to quantify the change in stiffness due to probe pressure. Results: Firm probe pressure decreased the measured aortic stiffness, and material stiffness was affected only when the wall was modeled as nonlinear, suggesting a shift in the stress–strain curve. In addition, stiffer surrounding tissues and a more elongated aneurysm sac decreased the responsiveness to the probe pressure. Conclusion: The effect of probe pressure on the AAA wall stiffness was clarified. In particular, the AAA wall nonlinear behavior was found to be of primary importance in determining the probe pressure response. Thus, further work will intend to make use of this novel finding in a clinical context.