  • Experimental Study on the Smoke Propagation in Subway Tunnels with Various Ventilation Modes

    by Minzhang Liu, Ni Gao, Kaisen Liang, Shu Liu, Rong Gao, Yifan Zhang, Xiaoran Wang, Bin Yang

  • An experimental investigation on cooling performance of a nanofluid-based radiant cooling system

    by Rong Gao, Xiaocong Liu, Zenan Gu, Xuan Guo, Yiming Li, Yun Li, Yuwen You, Yanping Lai, Bin Yang

  • A novel prediction model integrating physical information and data augmentation for fouling deposition in enhanced tubes

    by Rong Gao, Yuan Zhao, Chunmei Guo, Yuxin Huo, Yuwen You, Ke Yan, Bin Yang

    In traditional data center cooling systems, fouling deposition on the inner surfaces of enhanced tubes severely affects heat exchange efficiency and operational safety, leading to significant economic losses. Due to the lack of long-term fouling test data, most of the existing fouling prediction models are constant fouling factors or semi-empirical formulas established based on accelerated particulate fouling data. These models have low computational accuracy, poor generalizability, and certain limitations in engineering application constraints. To address these challenges, this study develops and validates a high-precision prediction model for combined fouling growth based on data augmentation using long-term fouling test data. First, to overcome the challenge of insufficient data, a physics-informed Wasserstein generative adversarial network with gradient penalty model is constructed in this study. The fouling thermal resistance database is expanded based on the generative adversarial network (GAN), utilizing the generated data as training sets. Simultaneously, the physical information is combined with the traditional GAN to establish a joint loss function containing physical constraints and improve the quality of the generated data. Second, a physics-informed-convolutional neural network-long short-term memory (LSTM)-Transformer model is introduced in this paper to improve prediction accuracy. To comprehensively extract the global feature information and the nonlinear relationship between each feature and the fouling thermal resistance, the Transformer is integrated with LSTM, creating a feature fusion fouling growth prediction model. Finally, SHapley Additive exPlanations were employed for interpretability analysis of the prediction model, with validation conducted using the long-term fouling test data from ASHRAE RP-1677. The results demonstrate that, compared to the baseline without data augmentation under various operating conditions, the average goodness-of-fit (R2) of the prediction model increased from −0.193 to 0.783, while the average prediction final bias decreased from 23.87% to 2.8%, confirming the superior performance of the proposed methodology.

  • Open Access

    Experimental and Numerical Investigation of the Effects of Passive Radiative Cooling-Air Layer Composite Envelope Structure on Building Energy Consumption for Data Center Rooms

    by Rong Gao, Weijin Sun, Yuxin Hao, Zhonglu He, Chunmei Guo, Xi Chen, Chong Meng

    The energy consumption of data centers has become increasingly prominent. To address the conflict between the characteristic of inhibiting heat dissipation for traditional insulated building envelopes and the cooling demands of data center rooms all year, this study proposes a novel composite envelope structure for data center rooms that integrates passive radiative cooling with air-layer insulation (PRC-AL). The results demonstrate that under internal heat source power densities of 300–1000 W/m2 without additional cooling measures, the PRC-AL composite envelope structure reduces indoor air temperatures by 16.16–30.81% compared to the traditional insulation structure (TIS). Meanwhile, the application of the PRC-AL composite envelope structure leads to significant reductions in annual cumulative cooling load per unit area: 1617.69 kWh/m2 in Harbin, 1359.49 kWh/m2 in Tianjin, 1135.25 kWh/m2 in Shanghai, 994.97 kWh/m2 in Guiyang, and 918.70 kWh/m2 in Guangzhou. These findings indicate that the proposed PRC-AL composite envelope structure not only effectively lowers indoor air temperatures but also reduces cooling loads in data center rooms, providing an efficient pathway for energy conservation in data centers. This research offers a theoretical foundation for optimizing the design of building envelopes in data centers and contributes to sustainable development in the digital infrastructure sector.


  • Open Access

    Influence Mechanism of the Nano-Structure on Phase Change Liquid Cooling Features for Data Centers

    by Yifan Li, Congzhe Zhu, Rong Gao, Bin Yang

    The local overheating issue is a serious threat to the safe operation of data centers (DCs). The chip-level liquid cooling with pool boiling is expected to solve this problem. The effect of nano configuration and surface wettability on the boiling characteristics of copper surfaces is studied using molecular dynamics (MD) simulation. The argon is chosen as the coolant, and the wall temperature is 300 K. The main findings and innovations are as follows. (1) Compared to the smooth surface and fin surface, the cylindrical nano cavity obtains the superior boiling performance with earlier onset of nucleate boiling (ONB), larger heat flux because of the higher heat transport rate. (2) The nano cavity with hydrophilicity can improve the response speed and heat dissipation efficiency. Compared to the contact angle θ = 121°, the formation times of nucleate bubble and film boiling for the θ = 0° are reduced by 90.84% and 93.57%, respectively. (3) A deeper cavity of 3.3 nm is beneficial for triggering boiling and improving the heat dissipation rate. The highest heat flux can be achieved at 21.86 × 108 W/m2, which can meet the cooling requirements of the micro devices with ultra-high heat flux (107–108 W/m2). The coupling effect of nano configuration and surface wettability is illustrated, and the essential reasons for the enhanced heat transport are revealed. The findings can guide the optimization of cooling systems and promote the practical application of phase change liquid cooling in DCs.


  • Study on performance optimization of a liquid desiccant air conditioning system driven by photovoltaic thermal–air source heat pump

    by Chunmei Guo, Ruxue Bai, Rong Gao, Yu Li, Hang Xiong, Zhonglu He, Yuwen You, Leilei Wang

    Compared to conventional condensation dehumidification systems, a solar liquid desiccant air conditioning system (SLDAC) offers distinct advantages, enabling independent control of temperature and humidity while operating at low carbon levels. This paper proposes a low-carbon SLDAC thermal mass exchange model that uses an indirect evaporative cooling liquid dehumidifier and photovoltaic thermal and air source heat pump for combined driving of the solution regeneration process. The system simulation model was created using MATLAB and TRNSYS software. An experimental comparison was conducted between the dehumidification module and the regeneration module, and the system's performance was simulated with an airflow of 150 m3/h in the Tianjin area. The results indicate an average dehumidification efficiency of 44.03% and a regeneration efficiency of 40.80% throughout the cooling season. During the cooling season, the power generation of the system met the power demand and produced a surplus of 85.36 kWh, achieving overall self-sufficiency in power consumption. The optimized system's operating parameters were proposed, with regeneration temperatures of 57 °C in June and September and 65 °C in July and August. During the cooling season, the system's regeneration capacity exceeded its dehumidification capacity for 84.90% of the operating time. As a result of optimization, the system's carbon emissions were reduced by 59.35%.