    Experimental and Numerical Investigation of the Effects of Passive Radiative Cooling-Air Layer Composite Envelope Structure on Building Energy Consumption for Data Center Rooms

    by Rong Gao, Weijin Sun, Yuxin Hao, Zhonglu He, Chunmei Guo, Xi Chen, Chong Meng

    The energy consumption of data centers has become increasingly prominent. To address the conflict between the characteristic of inhibiting heat dissipation for traditional insulated building envelopes and the cooling demands of data center rooms all year, this study proposes a novel composite envelope structure for data center rooms that integrates passive radiative cooling with air-layer insulation (PRC-AL). The results demonstrate that under internal heat source power densities of 300–1000 W/m2 without additional cooling measures, the PRC-AL composite envelope structure reduces indoor air temperatures by 16.16–30.81% compared to the traditional insulation structure (TIS). Meanwhile, the application of the PRC-AL composite envelope structure leads to significant reductions in annual cumulative cooling load per unit area: 1617.69 kWh/m2 in Harbin, 1359.49 kWh/m2 in Tianjin, 1135.25 kWh/m2 in Shanghai, 994.97 kWh/m2 in Guiyang, and 918.70 kWh/m2 in Guangzhou. These findings indicate that the proposed PRC-AL composite envelope structure not only effectively lowers indoor air temperatures but also reduces cooling loads in data center rooms, providing an efficient pathway for energy conservation in data centers. This research offers a theoretical foundation for optimizing the design of building envelopes in data centers and contributes to sustainable development in the digital infrastructure sector.


  • Experimental study on a cross-flow energy recovered indirect evaporative cooling (ERIEC)-assisted liquid desiccant dehumidifier (LDD) with improved spraying nozzle and surface wetness

    by Yanlin Ren, Chunmei Guo, Jian Lv, Jixiang Xu, Sihang Dong, Dandong Meng, Xuejian Ma, Shiwei Guo

    The film wetted area is a significant factor affecting the heat and mass transfer of liquid desiccant. In this article, a mathematical model with wetness coefficient of cross-flow energy recovered indirect evaporative cooling (ERIEC)-assisted liquid desiccant dehumidifier (LDD) based on a finite-element method was developed to predict the effect of wetness coefficient on the plate heat exchanger (PHE) effectiveness and dehumidification efficiency, taking into account the thermal resistance and incomplete wetting of liquid film. In addition, an experimental system of a cross-flow ERIEC-assisted LDD was established to validate the model; the validation of the model demonstrated good agreement with the experimental data to within 10%. With this model, increasing the wetness coefficient from 0.1 to 1, the PHE effectiveness gradually increased from 3.7% to 39.1% and the dehumidification efficiency increased gradually from 3.5% to 35.2%. This meant that the nonwetting or partial wetting of liquid film hindered the dehumidification performance. Therefore, a novel TiO2 super-hydrophilic coating was applied to raise the wetness coefficient and improve the dehumidification performance. Within the experimental range, spraying a super-hydrophilic coating (1% nanosized TiO2 solution) in the primary channel of the dehumidifier could increase the PHE effectiveness and dehumidification efficiency by 2.5–5% and 5–30%, respectively.