ABA. H. Bozhko

A. H. Bozhko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


A. H. Bozhko has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Expression of VEGF, BMP-2, and the OPG/RANK axis as indicators of osseointegration: a comparative clinical and experimental study of titanium implants with functional protective coatings

    by O.O. Bondarenko, A.E. Lievykh, N.S. Bondarenko, A.G. Bozhko, O.YE. Loskutov, I.S. Shponka

    The objective of the present study was to validate key mole­cular markers of bone tissue repair as indicators of osseointegration on systemic and local levels, and evaluate their trans­lational parallelism. This was achieved by comparing the configurational consistency of expression profiles between an experimental rat model and a pilot clinical investigation in human patients to synchronize systemic and local molecular responses. The hypothesis was that alumina-coated titanium implants would exhibit faster dynamics of angiogenic and osteogenic biomarkers, indicating accelerated osteoinduction, osteoconduction, and osseointegration compared with uncoated titanium. The pilot clinical study comprised the patients after total hip arthroplasty (n=6): three with uncoated titanium implants and three with alumina ceramics. Serum samples were collected from these patients in one and six months post-surgery. The experimental rat model comprised 160 Wistar females implanted with modified intrafemoral implants (seven surface types, including uncoated and alumina-coated titanium), with serum and peri-implant tissue samples collected in one, two, four, and eight weeks. Serum levels of vascular endothelial growth factor, bone morphogenetic protein 2, and osteoprotegerin were determined by enzyme-linked immunosorbent assay, while the corresponding local expression of vascular endothelial growth factor receptor, bone morphogenetic protein 2, and receptor activator of nuclear factor kappa-B was assessed by immunohistochemistry. The results demonstrated that alumina-coated implants induced an accelerated and synchronized molecular cascade in the rat model, which was qualitatively replicated in the clinical cohort. The systemic vascular endothelial growth factor peak manifested early, at one week in rats and one month in humans, and exhibited a strong parallelism with local microvessel density in the animal model, confirming rapid angiogenic activation. In both species, the expression of bone morphogenetic protein 2 increased earlier and to a greater extent in the alumina-coated groups, indicating more rapid osteoinduction. Local receptor activator of nuclear factor kappa-B activity demonstrated an early rise and a four-week peak in the groups with coated implants, consistent with controlled and timely bone remodelling. The study indicates that alumina coatings promote accelerated osseointegration by advancing the time course of healing, a conclusion supported by the observed translational parallelism of the investigated markers.

  • Open Access

    Systemic effect of alumina-coated titanium implants: histopathological analysis in rats

    by O. O. Bondarenko, A. H. Bozhko, S. A. Kalmykova, I. O. Maltsev, I. S. Shponka, O. Ye. Loskutov

    The systemic biocompatibility of implant materials is crucial for ensuring their safety, since materials such as titanium (Ti), hydroxyapatite (HAp) and, in particular, alumina (Al2O3) can affect vital organs beyond the site of implantation. While alumina-based coatings are valued for their mechanical stability, experimental studies suggest that aluminium ion release can cause toxicity to the liver and immune system. The aim of the study is to evaluate the organ-specific toxicity of Ti bone implants, both with and without functional-protective coatings, by conducting a histopathological analysis of the liver, kidney and spleen in an experimental model. Materials and methods. Cylindrical Ti pins, either uncoated, alumina-coated (Al), or HAp-coated, were produced and characterized previously. Ninety-five female Wistar rats were divided into four groups (Ti-, Al-, HAp-groups, and sham control). Implants were inserted into the right femur following by postsurgical treatment and observation. Liver, kidney, and spleen tissues were collected at 1, 2, 4, and 8 weeks and processed for blinded histopathological evaluation using a semi-quantitative scale (based on ISO 10993-11:2017). Statistical analysis utilized Kruskal–Wallis tests, with p < 0.05 denoting significance. Results. In the first week after implantation, all groups showed hepatocellular swelling, sinusoidal congestion and moderate portal mononuclear infiltration in the liver. They also showed tubular epithelial swelling and focal lymphocytic infiltration in the kidneys and follicular hyperplasia in the spleen. By the second week, these inflammatory alterations persisted but generally decreased, showing no significant difference from the sham-operated control group. By the fourth week, hepatocyte swelling and periportal infiltration were evident primarily in the Ti-group, while the Al2O3- and HAp-coated groups showed only mild reactions. Renal infiltration remained more pronounced in the Ti-group. By the eighth week, liver morphology was almost normal in all groups, with only minimal residual periportal infiltration. The kidneys showed only slight tubular swelling. While most splenic changes had resolved, some Ti-group specimens retained follicular hyperplasia, indicating a prolonged systemic response. Conclusions. This study confirms that all tested Ti-based biomaterials are acceptable in terms of systemic biocompatibility. No necrosis or irreversible organ damage was observed, indicating an absence of toxicity induced by the materials. The initial, transient histological changes were nonspecific responses to surgical stress. Systemic responses indirectly correlated with the implant surface. HAp coatings demonstrated the most favourable systemic profile due to their robust osseointegration, whereas uncoated Ti resulted in prolonged immune activation. This highlights the importance of coatings that promote rapid and complete osseointegration in minimizing long-term systemic effects.


  • Open Access

    Peri-implant osteogenesis on alumina-coated titanium implants in rat femur: morphological and elemental analysis of implant surfaces

    by O. O. Bondarenko, A. H. Bozhko, M. A. Skoryk, N. S. Bondarenko, I. S. Shponka, O. Ye. Loskutov

    Peri-implant bone tissue regeneration involves complex processes that are not yet fully understood at the cellular and molecular levels, leaving significant gaps in our knowledge that require further investigation. Aim. The study aimed to compare peri-implant osteogenesis on titanium femoral implants with alumina composite coatings applied by different methods to conventional titanium implants in an animal model. Materials and methods. Implants underwent sandblasting with silicon carbide, plasma torch treatment, and coating with titanium, corundum, sprayed titanium wire, or hydroxyapatite, resulting in seven different surfaces. 105 female Wistar rats received implants in their right femurs and were divided into 7 groups based on implant type and exposure duration (1, 2, or 4 weeks). Implant fragments were analyzed using scanning electron microscopy and energy dispersive X-ray spectroscopy to quantify chemical elements. Ratios of carbon to nitrogen and calcium to phosphorus were calculated. Data were analyzed using the U-Mann–Whitney test, with р < 0.05 as a significant value. Results. The energy dispersive X-spectrometry results confirmed morphological analysis findings by quantitatively and qualitatively assessing implants surface chemical composition. The key elements were evaluated, relevant for identifying bone tissue components like collagen (C and N) and hydroxyapatite (Ca and P), as well as implant coatings (Ti, Al, Ca, and P). Carbon and phosphorus showed fluctuations over time, with notable differences among groups. Aluminum appeared stable in some groups but varied in others. Calcium levels remained low initially and increased steadily in hydroxyapatite coated implants. Titanium levels were high initially, decreasing slightly over time. Morphological analysis correlated with surface roughness measurements. Notably, fibrin, collagen, and bone tissue presence varied among groups over time, with some groups showing significant mineralized bone tissue accumulation. After four weeks, blood clots persisted in some groups, while others exhibited bone tissue remodeling with the presence of osteoblasts and osteoclasts. Alumina-based coatings showed signs of degradation, with alumina cement scales found among macrophages and fibers. Conclusions. Our study found that stable bone implants outperform alumina-composite coatings in long-term osseointegration due to mechanical stability. Although ceramic composites initially enhance osteoinductive properties, better attachment to titanium substrates is needed.