IMI. O. Maltsev

I. O. Maltsev

*This is an algorithmically generated author record based on publicly available information.

I. O. Maltsev has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Osteoimmunomodulation by functional protective coatings: tuning innate and adaptive immunity for titanium implant osseointegration

    by O. O. Bondarenko, M. O. Rolduhina, N. S. Bondarenko, I. O. Maltsev, O. Y. Loskutov, I. S. Shpon’KA

    The long-term clinical reliability of intraosseous implants is often compromised by aseptic loosening, an implant failure mode driven by chronic inflammation and fibrous encapsulation. Current evidence suggests that osseointegration relies on complex osteoimmunological interactions rather than mechanical interlocking. This study aimed to investigate the immunomodulatory effects of functional protective coatings, specifically bioactive hydroxyapatite (HAp) and bio-inert alumina (Al2O3), on the interplay between innate and adaptive immune responses. A rat femoral model (n=160) was utilized, featuring seven distinct implant surface configurations varying in roughness (Ra 1.89-23.7 µm) and chemical composition. Peri-implant bone tissue harvesting was conducted at 1, 2, 4, and 8 weeks to capture the progression from acute to chronic inflammatory stages. The methodology employed a comprehensive immunohistochemical (IHC) analysis using specific markers: CD3 for T-cells, CD25 for activated lymphocytes, CD45R for B-cells, CD68 for pan-macrophages, and CD163 for the reparative M2 phenotype of macrophages. Statistical validation involved non-parametric Kruskal-Wallis analysis with Dunn’s post-hoc correction and Spearman’s rank correlation to quantify topographic versus chemical influences. Persistent T-cell-mediated inflammation characterized the peri-implant environment of the titanium control groups; regardless of surface roughness, these implants exhibited elevated densities of activated T-cells (CD3+/CD25+) sustained through the eighth week, confirming a chronic inflammation. Established bioactive HAp coatings significantly suppressed adaptive immune activation, promoting a decisive phenotypic shift toward reparative M2 macrophages (CD163+) and facilitating early woven bone formation by week 4. A distinct immunogenic failure mode was observed in the hybrid alumina-titanium coating group (TSPTC), where mechanical instability led to the release of coating particles, triggering specific B-cell (CD45R+) infiltration, indicative of a pathological humoral reaction rather than physiological myelointegration. Impact assessed by correlative analysis revealed no significant association between surface roughness and immune cell infiltration, whereas an increasing bioactivity rank correlated negatively with adaptive immune cell densities, indicating the dominant role of surface chemistry over topography in resolving inflammation. Characterized by regularities in immune crosstalk, the data showed that T-cell density positively correlated with activation markers, while the HAp layer acted as an immunological buffer, effectively masking the titanium substrate to prevent autocrine amplification of inflammation. Our study underscores the critical importance of stable functional protective coatings in tuning the peri-implant immune environment. Specifically, these coatings play a pivotal role in overriding chronic adaptive immune signals and promoting M2 macrophage polarization, thereby establishing the pro-reparative microenvironment necessary for long-term osseointegration.


  • Open Access

    Systemic effect of alumina-coated titanium implants: histopathological analysis in rats

    by O. O. Bondarenko, A. H. Bozhko, S. A. Kalmykova, I. O. Maltsev, I. S. Shponka, O. Ye. Loskutov

    The systemic biocompatibility of implant materials is crucial for ensuring their safety, since materials such as titanium (Ti), hydroxyapatite (HAp) and, in particular, alumina (Al2O3) can affect vital organs beyond the site of implantation. While alumina-based coatings are valued for their mechanical stability, experimental studies suggest that aluminium ion release can cause toxicity to the liver and immune system. The aim of the study is to evaluate the organ-specific toxicity of Ti bone implants, both with and without functional-protective coatings, by conducting a histopathological analysis of the liver, kidney and spleen in an experimental model. Materials and methods. Cylindrical Ti pins, either uncoated, alumina-coated (Al), or HAp-coated, were produced and characterized previously. Ninety-five female Wistar rats were divided into four groups (Ti-, Al-, HAp-groups, and sham control). Implants were inserted into the right femur following by postsurgical treatment and observation. Liver, kidney, and spleen tissues were collected at 1, 2, 4, and 8 weeks and processed for blinded histopathological evaluation using a semi-quantitative scale (based on ISO 10993-11:2017). Statistical analysis utilized Kruskal–Wallis tests, with p < 0.05 denoting significance. Results. In the first week after implantation, all groups showed hepatocellular swelling, sinusoidal congestion and moderate portal mononuclear infiltration in the liver. They also showed tubular epithelial swelling and focal lymphocytic infiltration in the kidneys and follicular hyperplasia in the spleen. By the second week, these inflammatory alterations persisted but generally decreased, showing no significant difference from the sham-operated control group. By the fourth week, hepatocyte swelling and periportal infiltration were evident primarily in the Ti-group, while the Al2O3- and HAp-coated groups showed only mild reactions. Renal infiltration remained more pronounced in the Ti-group. By the eighth week, liver morphology was almost normal in all groups, with only minimal residual periportal infiltration. The kidneys showed only slight tubular swelling. While most splenic changes had resolved, some Ti-group specimens retained follicular hyperplasia, indicating a prolonged systemic response. Conclusions. This study confirms that all tested Ti-based biomaterials are acceptable in terms of systemic biocompatibility. No necrosis or irreversible organ damage was observed, indicating an absence of toxicity induced by the materials. The initial, transient histological changes were nonspecific responses to surgical stress. Systemic responses indirectly correlated with the implant surface. HAp coatings demonstrated the most favourable systemic profile due to their robust osseointegration, whereas uncoated Ti resulted in prolonged immune activation. This highlights the importance of coatings that promote rapid and complete osseointegration in minimizing long-term systemic effects.