Fengming Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fengming Shi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Siyang Liao
Wuhan University
3 shared publications - Shaobo Yang
Research Institute of Electric Power Science, State Grid Hebei Electric Power Co., Shijiazhuang 050021, China
2 shared publications - Hao Zhou
Research Institute of Electric Power Science, State Grid Hebei Electric Power Co., Shijiazhuang 050021, China
1 shared publication - Hengrong Zhang
Electric Power Science Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication - Kailei Chen
Electric Power Science Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication - Lei Wang
State Grid Hebei Electric Power Company Electric Power Research Institute, Shijiazhuang 050021, China
1 shared publication
Latest Publications
- Open Access
Assessment Method for Dynamic Adjustable Capacity of Distribution Network Feeder Load Based on CNN-LSTM Source–Load Forecasting
In response to the demand for flexible regulation resources in distribution networks with high proportion of new energy integration, this study explores the regulation potential of feeder loads. It controls the power of feeder loads through various types of voltage regulation equipment, treating these loads as a key component of virtual power plants (VPPs) to participate in grid security and stability control, demand response, and other fields, thereby enhancing the operational flexibility of the system. This paper focuses on the research of dynamic adjustable capacity evaluation for feeder loads, aiming to provide capacity constraints for their participation in grid interaction. Firstly, a CVR coefficient model is established based on the voltage–power coupling characteristics of feeder loads to characterize their regulation properties. Secondly, an analytical expression for voltage sensitivity is derived using an improved Zbus linearized power flow model, and a system-wide node voltage prediction model is constructed by combining the source–load prediction results from the CNN-LSTM model. On this basis, the dynamic regulation boundaries of each node’s voltage are solved with the constraint of system-wide voltage security. The adjustable capacity for the next 3 h is calculated iteratively by integrating the CVR coefficients of each feeder load, realizing the dynamic evaluation of the regulation capability of feeder loads.
Open AccessAssessment Method for Dynamic Adjustable Capacity of Distribution Network Feeder Load Based on CNN-LSTM Source–Load Forecasting
In response to the demand for flexible regulation resources in distribution networks with high proportion of new energy integration, this study explores the regulation potential of feeder loads. It controls the power of feeder loads through various types of voltage regulation equipment, treating these loads as a key component of virtual power plants (VPPs) to participate in grid security and stability control, demand response, and other fields, thereby enhancing the operational flexibility of the system. This paper focuses on the research of dynamic adjustable capacity evaluation for feeder loads, aiming to provide capacity constraints for their participation in grid interaction. Firstly, a CVR coefficient model is established based on the voltage–power coupling characteristics of feeder loads to characterize their regulation properties. Secondly, an analytical expression for voltage sensitivity is derived using an improved Zbus linearized power flow model, and a system-wide node voltage prediction model is constructed by combining the source–load prediction results from the CNN-LSTM model. On this basis, the dynamic regulation boundaries of each node’s voltage are solved with the constraint of system-wide voltage security. The adjustable capacity for the next 3 h is calculated iteratively by integrating the CVR coefficients of each feeder load, realizing the dynamic evaluation of the regulation capability of feeder loads.
- Open Access
Control Strategy for Power Fluctuation Smoothing at Distribution Network Substations Considering Multiple Types of Adjustment Resources
With the proposal of the dual carbon target, the distributed photovoltaic (PV) industry has rapidly developed in recent years. However, the randomness and volatility of photovoltaic energy can be transmitted to the main grid through distribution network substations, posing challenges to the stable operation of the power system. Therefore, this paper considers tapping into the regulation potential of feeder loads on the distribution network side, as well as distributed energy storage and distributed PV resources, to enhance the grid’s control methods. A power fluctuation smoothing control strategy for substations in distribution networks, accounting for multiple types of regulation resources, is proposed. In the day-ahead stage, traditional voltage regulation devices such as the OLTC (on-load tap changer) and CB (circuit breaker) are pre-dispatched based on source–load forecasts, optimizing the fluctuation range of substation power and the number of device operations. This provides optimal substation power values for day-to-day optimization. During the intraday phase, fast regulation devices such as PV (photovoltaic), SVC (static var compensator), and energy storage systems are coordinated, and an optimization model is established with the goal of reducing power curtailment while closely tracking substation trends. This model quickly calculates the active power regulation and device operations of various adjustable resources, improving the economic efficiency of the distribution network system while achieving power fluctuation smoothing at the substation level. Finally, the feasibility and effectiveness of the power fluctuation smoothing control model are verified through simulations on an improved standard distribution system.
Open AccessControl Strategy for Power Fluctuation Smoothing at Distribution Network Substations Considering Multiple Types of Adjustment Resources
With the proposal of the dual carbon target, the distributed photovoltaic (PV) industry has rapidly developed in recent years. However, the randomness and volatility of photovoltaic energy can be transmitted to the main grid through distribution network substations, posing challenges to the stable operation of the power system. Therefore, this paper considers tapping into the regulation potential of feeder loads on the distribution network side, as well as distributed energy storage and distributed PV resources, to enhance the grid’s control methods. A power fluctuation smoothing control strategy for substations in distribution networks, accounting for multiple types of regulation resources, is proposed. In the day-ahead stage, traditional voltage regulation devices such as the OLTC (on-load tap changer) and CB (circuit breaker) are pre-dispatched based on source–load forecasts, optimizing the fluctuation range of substation power and the number of device operations. This provides optimal substation power values for day-to-day optimization. During the intraday phase, fast regulation devices such as PV (photovoltaic), SVC (static var compensator), and energy storage systems are coordinated, and an optimization model is established with the goal of reducing power curtailment while closely tracking substation trends. This model quickly calculates the active power regulation and device operations of various adjustable resources, improving the economic efficiency of the distribution network system while achieving power fluctuation smoothing at the substation level. Finally, the feasibility and effectiveness of the power fluctuation smoothing control model are verified through simulations on an improved standard distribution system.
- Open Access
Evaluation Method for Voltage Regulation Range of Medium-Voltage Substations Based on OLTC Pre-Dispatch
A new energy industry represented by photovoltaic and wind power has been developing rapidly in recent years, and its randomness and volatility will impact the stable operation of the power system. At present, it is proposed to enrich the regulation of the power grid by tapping the regulation potential of load-side resources. This paper evaluates the overall voltage regulation capability of substations under the premise of considering the impact on network voltage security and providing a theoretical basis for the participation of load-side resources of distribution networks in the regulation of the power grid. This paper proposes a Zbus linear power flow model based on Fixed-Point Power Iteration (FFPI) to enhance power flow analysis efficiency and resolve voltage sensitivity expression. Establishing the linear relationship between the voltages of PQ nodes, the voltage of the reference node, and the load power, this paper clarifies the impact of reactive power compensation devices and OLTC (on-load tap changer) tap changes on the voltages of various nodes along the feeder. It provides theoretical support for evaluating the voltage regulation range for substations. The day-ahead focus is on minimizing network losses by pre-optimizing OLTC tap positions, calculating the substation voltage regulation boundaries within the day, and simultaneously optimizing the total reactive power compensation across the entire network. By analyzing the calculated examples, it was found that a pre-scheduled OLTC (on-load tap changer) can effectively reduce network losses in the distribution grid. Compared with traditional methods, the voltage regulation range assessment method proposed in this paper can optimize the adjustment of reactive power compensation devices while ensuring the voltage safety of all nodes in the network.
Open AccessEvaluation Method for Voltage Regulation Range of Medium-Voltage Substations Based on OLTC Pre-Dispatch
A new energy industry represented by photovoltaic and wind power has been developing rapidly in recent years, and its randomness and volatility will impact the stable operation of the power system. At present, it is proposed to enrich the regulation of the power grid by tapping the regulation potential of load-side resources. This paper evaluates the overall voltage regulation capability of substations under the premise of considering the impact on network voltage security and providing a theoretical basis for the participation of load-side resources of distribution networks in the regulation of the power grid. This paper proposes a Zbus linear power flow model based on Fixed-Point Power Iteration (FFPI) to enhance power flow analysis efficiency and resolve voltage sensitivity expression. Establishing the linear relationship between the voltages of PQ nodes, the voltage of the reference node, and the load power, this paper clarifies the impact of reactive power compensation devices and OLTC (on-load tap changer) tap changes on the voltages of various nodes along the feeder. It provides theoretical support for evaluating the voltage regulation range for substations. The day-ahead focus is on minimizing network losses by pre-optimizing OLTC tap positions, calculating the substation voltage regulation boundaries within the day, and simultaneously optimizing the total reactive power compensation across the entire network. By analyzing the calculated examples, it was found that a pre-scheduled OLTC (on-load tap changer) can effectively reduce network losses in the distribution grid. Compared with traditional methods, the voltage regulation range assessment method proposed in this paper can optimize the adjustment of reactive power compensation devices while ensuring the voltage safety of all nodes in the network.