Kailei Chen
Kailei Chen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Youzhuo Zheng
Electric Power Science Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
2 shared publications - Chun Li
Electric Power Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication - Fengming Shi
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
1 shared publication - Hengrong Zhang
Electric Power Science Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication - Long Hua
Electric Power Research Institute of Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication - Nuoqing Shen
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
1 shared publication
Latest Publications
- Open Access
Assessment Method for Dynamic Adjustable Capacity of Distribution Network Feeder Load Based on CNN-LSTM Source–Load Forecasting
In response to the demand for flexible regulation resources in distribution networks with high proportion of new energy integration, this study explores the regulation potential of feeder loads. It controls the power of feeder loads through various types of voltage regulation equipment, treating these loads as a key component of virtual power plants (VPPs) to participate in grid security and stability control, demand response, and other fields, thereby enhancing the operational flexibility of the system. This paper focuses on the research of dynamic adjustable capacity evaluation for feeder loads, aiming to provide capacity constraints for their participation in grid interaction. Firstly, a CVR coefficient model is established based on the voltage–power coupling characteristics of feeder loads to characterize their regulation properties. Secondly, an analytical expression for voltage sensitivity is derived using an improved Zbus linearized power flow model, and a system-wide node voltage prediction model is constructed by combining the source–load prediction results from the CNN-LSTM model. On this basis, the dynamic regulation boundaries of each node’s voltage are solved with the constraint of system-wide voltage security. The adjustable capacity for the next 3 h is calculated iteratively by integrating the CVR coefficients of each feeder load, realizing the dynamic evaluation of the regulation capability of feeder loads.
Open AccessAssessment Method for Dynamic Adjustable Capacity of Distribution Network Feeder Load Based on CNN-LSTM Source–Load Forecasting
In response to the demand for flexible regulation resources in distribution networks with high proportion of new energy integration, this study explores the regulation potential of feeder loads. It controls the power of feeder loads through various types of voltage regulation equipment, treating these loads as a key component of virtual power plants (VPPs) to participate in grid security and stability control, demand response, and other fields, thereby enhancing the operational flexibility of the system. This paper focuses on the research of dynamic adjustable capacity evaluation for feeder loads, aiming to provide capacity constraints for their participation in grid interaction. Firstly, a CVR coefficient model is established based on the voltage–power coupling characteristics of feeder loads to characterize their regulation properties. Secondly, an analytical expression for voltage sensitivity is derived using an improved Zbus linearized power flow model, and a system-wide node voltage prediction model is constructed by combining the source–load prediction results from the CNN-LSTM model. On this basis, the dynamic regulation boundaries of each node’s voltage are solved with the constraint of system-wide voltage security. The adjustable capacity for the next 3 h is calculated iteratively by integrating the CVR coefficients of each feeder load, realizing the dynamic evaluation of the regulation capability of feeder loads.
- Open Access
Transient Stability Control Method for Droop-Controlled Photovoltaics, Based on Power Angle Deviation Feedback
Distributed photovoltaic grid-connected converters adopting droop control can provide dual support for voltage and frequency in the distribution system. However, under fault conditions, droop-controlled inverters will face the problem of transient synchronization instability, and their transient characteristics are significantly affected by fault conditions, control parameter configurations, and other factors. Nevertheless, at present, the transient operation boundaries of droop inverters, considering key sensitive parameters, are unclear, and the transient stability control mechanism is lacking, which poses a threat to the safe and stable operation of distributed photovoltaic systems. To this end, this paper fully considers the influences of control parameters and fault severity and conducts a multidimensional quantitative characterization of the transient stability boundaries of droop-controlled inverters. Furthermore, a stability enhancement control structure for droop-controlled inverters, based on power angle deviation feedforward, is proposed, and an adaptive configuration method for feedforward coefficients is put forward to ensure the safe and stable operation of droop inverters at different fault sag depths. Finally, the accuracy of the theoretical analysis and the proposed control structure is verified through simulations and experiments.
Open AccessTransient Stability Control Method for Droop-Controlled Photovoltaics, Based on Power Angle Deviation Feedback
Distributed photovoltaic grid-connected converters adopting droop control can provide dual support for voltage and frequency in the distribution system. However, under fault conditions, droop-controlled inverters will face the problem of transient synchronization instability, and their transient characteristics are significantly affected by fault conditions, control parameter configurations, and other factors. Nevertheless, at present, the transient operation boundaries of droop inverters, considering key sensitive parameters, are unclear, and the transient stability control mechanism is lacking, which poses a threat to the safe and stable operation of distributed photovoltaic systems. To this end, this paper fully considers the influences of control parameters and fault severity and conducts a multidimensional quantitative characterization of the transient stability boundaries of droop-controlled inverters. Furthermore, a stability enhancement control structure for droop-controlled inverters, based on power angle deviation feedforward, is proposed, and an adaptive configuration method for feedforward coefficients is put forward to ensure the safe and stable operation of droop inverters at different fault sag depths. Finally, the accuracy of the theoretical analysis and the proposed control structure is verified through simulations and experiments.