Tzadok Yona
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tzadok Yona has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Ron Gilat
Sports Injuries Division and Joint Preservation Center, Department of Orthopaedic Surgery, Tel Aviv Medical Center, Tel Aviv, Israel
4 shared publications Dror Lindner
School of Medicine, Tel Aviv University, Tel Aviv, Israel
2 shared publications- Yiftah Beer
Department of Orthopaedic Surgery Shamir Medical Center Tel Aviv Israel
2 shared publications - Achia Nemet
Department of Ophthalmology, Assuta Ashdod University Medical Center, Ashdod, Israel
1 shared publication Adam Daniel Mozes
Department of Orthopedics, Edith Wolfson Medical Center, Tel Aviv, Israel
1 shared publication- Adir Sommer
Department of Ophthalmology, Rambam Health Care Campus, Haifa, Israel
1 shared publication
Latest Publications
- Open Access
- 30 August 2026
- Published by Wiley in Arthroscopy
- Vol. 42 (11) , 2672-2673
Editorial Commentary : Chekhov's Unloaded Gun—The Fate of a Knee Cartilage Biopsy Taken in the First Act
Matrix‐induced autologous chondrocyte implantation is a well‐established, staged cartilage repair procedure. However, historical data suggests that most patients undergoing the initial index biopsy procedure do not proceed to definitive implantation. Although various predictors for conversion have been proposed, including body mass index, lesion size, defect grade, and surgical history, significant discrepancies persist across the literature. Accurately predicting which patients will convert is critical for 2 primary reasons: first, to minimize unnecessary iatrogenic cartilage damage from nonused biopsies, and second, to mitigate health care waste and optimize resource allocation. Currently, precisely identifying the patient cohorts most likely to undergo implantation remains a clinical challenge, underscoring the need for large‐scale consensus data to guide patient counseling and surgical decision‐making.
- 30 August 2026
- Published by Wiley in Arthroscopy
- Vol. 42 (11) , 2672-2673
Open AccessEditorial Commentary : Chekhov's Unloaded Gun—The Fate of a Knee Cartilage Biopsy Taken in the First Act
Matrix‐induced autologous chondrocyte implantation is a well‐established, staged cartilage repair procedure. However, historical data suggests that most patients undergoing the initial index biopsy procedure do not proceed to definitive implantation. Although various predictors for conversion have been proposed, including body mass index, lesion size, defect grade, and surgical history, significant discrepancies persist across the literature. Accurately predicting which patients will convert is critical for 2 primary reasons: first, to minimize unnecessary iatrogenic cartilage damage from nonused biopsies, and second, to mitigate health care waste and optimize resource allocation. Currently, precisely identifying the patient cohorts most likely to undergo implantation remains a clinical challenge, underscoring the need for large‐scale consensus data to guide patient counseling and surgical decision‐making.
- 20 August 2026
- Published by Wiley in Arthroscopy
All‐Inside Meniscus Repair Systems Failure Analysis Shows Device‐Related Adverse Events Differ by Device Design Type and Show Varied Reporting Delays by Manufacturer
Purpose: To investigate common failures of all‐inside meniscal repair devices and associated patient injuries and determine whether specific device designs show distinct patterns of adverse events. Methods: The Food and Drug Administration's Manufacturer and User Facility Device Experience database was queried for adverse events involving all‐inside meniscal repair devices from 2023 to 2024. Data collected included device problems, patient injuries, manufacturer details, and time to report incidents. Device problems were categorized into 11 groups: Detachment of Device or Device Component, Failure to Fire, Fracture, Device‐Device Incompatibility, Simultaneous Fire, Premature Activation, Physical Resistance/Sticking, Manufacturing, Packaging or Shipping Problem, Sutures Torn, Material Deformation, and Separation Failure. Statistical analyses included frequency counts, percentages, and Kruskal‐Wallis test, with significance at P < .05. Results: Three thousand fifty‐six device malfunctions were reported in 2023 to 2024. After excluding 8 nonmeniscal repair devices, 908 duplicates and 84 reports lacking sufficient information, 2056 eligible reports were analyzed. Among these, 114 associated patient injuries (5.5%). The most frequent device problems were Device Detachment (486, 20.76%), Failure to Fire (473, 20.21%), Device Fracture (362, 15.46%), and Device‐Device Incompatibility (346, 14.78%). Reporting delays varied significantly by manufacturer, ranging from a median of 13 to 33.5 days ( P < .001). Reported device problems varied significantly by design group ( P < .001). All‐suture anchors showed the highest rate of Device Fracture (101, 41.6%), whereas rigid capsular‐knot anchors were uniquely associated with Device‐Device Incompatibility (346, 34.0%). Rigid meniscal‐knot anchors predominantly failed due to deployment errors, most notably “Failure to Fire” (391, 36.2%) and “Simultaneous Fire” (215, 19.9%). Conclusions: Adverse event causes differed by system design. All‐suture anchors most frequently failed by Fracture of the device, rigid anchors with a capsular knot showed a unique susceptibility to Device‐Device Incompatibility, and rigid anchors with a meniscal knot were primarily associated with deployment‐related errors. Level of Evidence: Level IV, retrospective comparative cohort.
- 20 August 2026
- Published by Wiley in Arthroscopy
All‐Inside Meniscus Repair Systems Failure Analysis Shows Device‐Related Adverse Events Differ by Device Design Type and Show Varied Reporting Delays by Manufacturer
Purpose: To investigate common failures of all‐inside meniscal repair devices and associated patient injuries and determine whether specific device designs show distinct patterns of adverse events. Methods: The Food and Drug Administration's Manufacturer and User Facility Device Experience database was queried for adverse events involving all‐inside meniscal repair devices from 2023 to 2024. Data collected included device problems, patient injuries, manufacturer details, and time to report incidents. Device problems were categorized into 11 groups: Detachment of Device or Device Component, Failure to Fire, Fracture, Device‐Device Incompatibility, Simultaneous Fire, Premature Activation, Physical Resistance/Sticking, Manufacturing, Packaging or Shipping Problem, Sutures Torn, Material Deformation, and Separation Failure. Statistical analyses included frequency counts, percentages, and Kruskal‐Wallis test, with significance at P < .05. Results: Three thousand fifty‐six device malfunctions were reported in 2023 to 2024. After excluding 8 nonmeniscal repair devices, 908 duplicates and 84 reports lacking sufficient information, 2056 eligible reports were analyzed. Among these, 114 associated patient injuries (5.5%). The most frequent device problems were Device Detachment (486, 20.76%), Failure to Fire (473, 20.21%), Device Fracture (362, 15.46%), and Device‐Device Incompatibility (346, 14.78%). Reporting delays varied significantly by manufacturer, ranging from a median of 13 to 33.5 days ( P < .001). Reported device problems varied significantly by design group ( P < .001). All‐suture anchors showed the highest rate of Device Fracture (101, 41.6%), whereas rigid capsular‐knot anchors were uniquely associated with Device‐Device Incompatibility (346, 34.0%). Rigid meniscal‐knot anchors predominantly failed due to deployment errors, most notably “Failure to Fire” (391, 36.2%) and “Simultaneous Fire” (215, 19.9%). Conclusions: Adverse event causes differed by system design. All‐suture anchors most frequently failed by Fracture of the device, rigid anchors with a capsular knot showed a unique susceptibility to Device‐Device Incompatibility, and rigid anchors with a meniscal knot were primarily associated with deployment‐related errors. Level of Evidence: Level IV, retrospective comparative cohort.
- Open Access
- 28 May 2025
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 35 (6) , 2298-2304
Wait times in pediatric ophthalmology clinics: Insights from a tertiary university hospital
Purpose: To analyze wait time (WT) trends at Pediatric Ophthalmology and Strabismus (POS) service clinics. Methods: Retrospective observational study utilizing MDClone and electronic health records (EHRs) on 19,018 patients from POS clinics at a tertiary university-affiliated hospital in Israel, during April 2016-June 2023. Data were collected by the qFlow real-time patient tracking system. Primary outcome measures were WTs trends. Results: Data consisted of 19,018 patients, and the final cohort was 11,320 patients (49.51% female). Median age was 6 (IQR: 7) and median WT was 34.14 (IQR: 16.52–60.35) minutes. WT decreased during the pandemic (p < 0.001). WT across different eye clinics at the POS service differed (p < 0.001). Average WTs differed throughout the day: gradually decreasing from front desk opening until accepting patients, gradually increasing before noon, and followed by a gradual decrease. WTs fluctuated throughout the year with no clear pattern (31 min in May vs. 37 min in July, p < 0.001). There was a significant, weak, negative correlation between patients’ lateness and WT, suggesting late arrivals were admitted quicker (p < 0.001). Median WT was not associated with gender (p = 0.93) or religion (p = 0.11) and with age (R = 0.02, p = 0.14). Conclusion: WTs remained stable over the years. WTs at the POS service were significantly influenced by the time of day, month, type of clinic, and arrival time relative to the set appointment. WTs were significantly decreased during the COVID-19 epidemic. Personalized clinic schedules and adjusting for the complexity of needing both an orthoptist and ophthalmologist, may shorten WTs and encourage patients to avoid early arrivals.
- 28 May 2025
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 35 (6) , 2298-2304
Open AccessWait times in pediatric ophthalmology clinics: Insights from a tertiary university hospital
Purpose: To analyze wait time (WT) trends at Pediatric Ophthalmology and Strabismus (POS) service clinics. Methods: Retrospective observational study utilizing MDClone and electronic health records (EHRs) on 19,018 patients from POS clinics at a tertiary university-affiliated hospital in Israel, during April 2016-June 2023. Data were collected by the qFlow real-time patient tracking system. Primary outcome measures were WTs trends. Results: Data consisted of 19,018 patients, and the final cohort was 11,320 patients (49.51% female). Median age was 6 (IQR: 7) and median WT was 34.14 (IQR: 16.52–60.35) minutes. WT decreased during the pandemic (p < 0.001). WT across different eye clinics at the POS service differed (p < 0.001). Average WTs differed throughout the day: gradually decreasing from front desk opening until accepting patients, gradually increasing before noon, and followed by a gradual decrease. WTs fluctuated throughout the year with no clear pattern (31 min in May vs. 37 min in July, p < 0.001). There was a significant, weak, negative correlation between patients’ lateness and WT, suggesting late arrivals were admitted quicker (p < 0.001). Median WT was not associated with gender (p = 0.93) or religion (p = 0.11) and with age (R = 0.02, p = 0.14). Conclusion: WTs remained stable over the years. WTs at the POS service were significantly influenced by the time of day, month, type of clinic, and arrival time relative to the set appointment. WTs were significantly decreased during the COVID-19 epidemic. Personalized clinic schedules and adjusting for the complexity of needing both an orthoptist and ophthalmologist, may shorten WTs and encourage patients to avoid early arrivals.
- Open Access
- 22 May 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (1) , 287-295
Combined proximal humerus fractures are associated with greater mortality and morbidity compared with isolated fractures: a retrospective cohort study
- 22 May 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (1) , 287-295
Open AccessCombined proximal humerus fractures are associated with greater mortality and morbidity compared with isolated fractures: a retrospective cohort study
- 19 December 2024
- Published by SAGE Publications in Shoulder & Elbow
The effect of rotator cuff repair on sleep quality: Influencing factors and the impact of narcotic medication on postoperative sleep patterns: A systematic review and meta-analysis
Background: Impaired sleep quality often drives patients with rotator cuff tears (RCT) to seek surgical intervention. This meta-analysis reviews the impact of arthroscopic rotator cuff repair (ARCR) on sleep quality beyond six months and identifies influencing factors, primarily narcotics, on sleep quality. Methods: The search spanned PubMed, Google Scholar, Embase, and the Cochrane Central Register, targeting articles evaluating rotator cuff injury and sleep quality. Information gathered included study features, bias risk assessment, evaluation of sleep quality using sleep-specific patient-reported outcomes, and the effects of opiates on sleep outcomes. Results: Ten studies, including 445 patients who underwent ARCR were included. The preoperative mean Pittsburgh Sleep Quality Index (PSQI) varied from 6.6 to 15. Eight studies presented a mean PSQI score of 3.6–7.1 at 6 months postoperatively; two studies reported mean score of 4.2 and 5.4 at 12 months. Both were found to be statistically significant by this meta-analysis compared to preoperative scores. Three studies found narcotic use, RCT size, alcohol consumption, diabetes, and hypertension to negatively affect PSQI scores. Discussion: Arthroscopic rotator cuff repair significantly improves sleep quality at 6 and 12 months following surgery. Perioperative narcotic use, RCT size, alcohol consumption, diabetes, and hypertension may negatively impact sleep quality.
- 19 December 2024
- Published by SAGE Publications in Shoulder & Elbow
The effect of rotator cuff repair on sleep quality: Influencing factors and the impact of narcotic medication on postoperative sleep patterns: A systematic review and meta-analysis
Background: Impaired sleep quality often drives patients with rotator cuff tears (RCT) to seek surgical intervention. This meta-analysis reviews the impact of arthroscopic rotator cuff repair (ARCR) on sleep quality beyond six months and identifies influencing factors, primarily narcotics, on sleep quality. Methods: The search spanned PubMed, Google Scholar, Embase, and the Cochrane Central Register, targeting articles evaluating rotator cuff injury and sleep quality. Information gathered included study features, bias risk assessment, evaluation of sleep quality using sleep-specific patient-reported outcomes, and the effects of opiates on sleep outcomes. Results: Ten studies, including 445 patients who underwent ARCR were included. The preoperative mean Pittsburgh Sleep Quality Index (PSQI) varied from 6.6 to 15. Eight studies presented a mean PSQI score of 3.6–7.1 at 6 months postoperatively; two studies reported mean score of 4.2 and 5.4 at 12 months. Both were found to be statistically significant by this meta-analysis compared to preoperative scores. Three studies found narcotic use, RCT size, alcohol consumption, diabetes, and hypertension to negatively affect PSQI scores. Discussion: Arthroscopic rotator cuff repair significantly improves sleep quality at 6 and 12 months following surgery. Perioperative narcotic use, RCT size, alcohol consumption, diabetes, and hypertension may negatively impact sleep quality.
- 4 September 2024
- Published by Wolters Kluwer Health in Clinical Journal of Sport Medicine
- Vol. 35 (4) , 498-504
Kiteboarding Injuries: Epidemiology, Common Treatment Strategies, and Time to Return to Kiteboarding Following Injury
Objective: To evaluate the prevalence and types of injuries incurred during kiteboarding (1), along with treatment approaches (2). In addition, the time to return to kiteboarding following injury (3) and factors associated with the rate and type of injury were analyzed (4). Setting: Recreational kiteboarding. Design: Retrospective cohort. Participants: Three hundred twelve kiteboarders (280 men, 32 women, mean age 42.91 ± 13) were included in the study. Independent Variables: Age, sex, experience, and the use of protective gear. Main Outcome Measures: Kiteboarding experience, injury location, type, incidence, nonsurgical and surgical treatment modalities, and return-to-kiteboarding data. Results: The number of injuries calculated per 1000 sessions was a mean of 7.82 (4.83-10.81). Patients with less than 2 years of kiteboarding experience were at a greater risk of injury than more experienced kiters (P < 0.001). The knee (24.1%), ankle and foot (18.9%), ribs (12.7%), and shoulder (10.2%) were the body parts most frequently injured. Overall, 14.4% of kiters underwent surgical intervention, with knee surgery being the most common site of operation (41.9%) and the most frequently performed procedure being anterior cruciate ligament reconstruction. Conclusions: The pattern of reported injury was found to be different from that previously reported in the scientific literature among freeriding kiters, with knees, ribs, and shoulders being most frequently involved. Participants with <2 years of experience had a significantly greater risk of injury; therefore, proper technical and physical training is advisable.
- 4 September 2024
- Published by Wolters Kluwer Health in Clinical Journal of Sport Medicine
- Vol. 35 (4) , 498-504
Kiteboarding Injuries: Epidemiology, Common Treatment Strategies, and Time to Return to Kiteboarding Following Injury
Objective: To evaluate the prevalence and types of injuries incurred during kiteboarding (1), along with treatment approaches (2). In addition, the time to return to kiteboarding following injury (3) and factors associated with the rate and type of injury were analyzed (4). Setting: Recreational kiteboarding. Design: Retrospective cohort. Participants: Three hundred twelve kiteboarders (280 men, 32 women, mean age 42.91 ± 13) were included in the study. Independent Variables: Age, sex, experience, and the use of protective gear. Main Outcome Measures: Kiteboarding experience, injury location, type, incidence, nonsurgical and surgical treatment modalities, and return-to-kiteboarding data. Results: The number of injuries calculated per 1000 sessions was a mean of 7.82 (4.83-10.81). Patients with less than 2 years of kiteboarding experience were at a greater risk of injury than more experienced kiters (P < 0.001). The knee (24.1%), ankle and foot (18.9%), ribs (12.7%), and shoulder (10.2%) were the body parts most frequently injured. Overall, 14.4% of kiters underwent surgical intervention, with knee surgery being the most common site of operation (41.9%) and the most frequently performed procedure being anterior cruciate ligament reconstruction. Conclusions: The pattern of reported injury was found to be different from that previously reported in the scientific literature among freeriding kiters, with knees, ribs, and shoulders being most frequently involved. Participants with <2 years of experience had a significantly greater risk of injury; therefore, proper technical and physical training is advisable.