Wenjing Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenjing Zhu has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Xuetao Shi
Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
4 shared publications - Lei Wang
Institute of Medical Research, Northwestern Polytechnical University, Xian, China
3 shared publications - Zhenyu Ji
Faculty of Biomedical Engineering, Fourth Military Medical University, Xian, China
3 shared publications - Junyao Li
Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Deterction and Intelligent Perception, Air Force Medical University, Xi’an, China
2 shared publications - Mingxu Zhu
Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Deterction and Intelligent Perception, Air Force Medical University, Xi’an, China
2 shared publications - Ruteng Song
Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Deterction and Intelligent Perception, Air Force Medical University, Xi’an, China
2 shared publications
Latest Publications
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 4008214
EEG–EIT Synchronous Acquisition System: Development and Preliminary Application in Epileptic Seizure Detection
To address the need for precise localization of refractory epileptic foci, this study developed a synchronous EEG-EIT detection system and validated the feasibility and accuracy of using electrical impedance tomography (EIT) for epileptogenic zone localizing. The system utilizes a single set of electrodes to achieve co-located, simultaneous, and same-channel acquisition of impedance and EEG signals. Cross-interference between devices was eliminated through a dual-domain cooperative strategy combining "hardware low-pass" and "software comb" filtering, ensuring the precision of signal acquisition. System performance was systematically evaluated using a kainic acid (KA)-induced epilepsy model in ten adult male Sprague-Dawley rats. Signals were acquired under three conditions: independent acquisition (reference baseline), synchronous acquisition without filtering (interference state), and synchronous acquisition with filtering (post-interference suppression). After filtering, the impedance difference between synchronous and independent EIT recordings was only 0.15% under normal conditions and 0.71% during seizures. The reconstructed EIT images achieved a structural similarity index (SSIM) of 0.97 and a Dice coefficient of 0.80. The filtered EEG signals exhibited high similarity to independently recorded signals, with cosine similarity and correlation coefficients both exceeding 0.80 under both normal and epileptic conditions. Spatial consistency analysis revealed that the average deviation between the centroid of the epileptogenic zone localized by EIT and that derived from EEG topography was only 0.13 mm, with a mean relative error of 6.37%. Histological examination confirmed that the regions identified by EIT corresponded to areas exhibiting characteristic epileptic neuronal damage. In 80% of seizures, a sustained impedance decrease (7.48% ± 5.339%) was observed in the focal region, and the area of decreased impedance gradually expanded during seizure progression. These results demonstrate that the system can reliably acquire multimodal signals, accurately localize epileptic foci, and monitor dynamic impedance changes during seizure activity. This study provides a foundational platform for future research on multimodal fusion-based epilepsy diagnosis and the development of portable neural monitoring devices.
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 4008214
EEG–EIT Synchronous Acquisition System: Development and Preliminary Application in Epileptic Seizure Detection
To address the need for precise localization of refractory epileptic foci, this study developed a synchronous EEG-EIT detection system and validated the feasibility and accuracy of using electrical impedance tomography (EIT) for epileptogenic zone localizing. The system utilizes a single set of electrodes to achieve co-located, simultaneous, and same-channel acquisition of impedance and EEG signals. Cross-interference between devices was eliminated through a dual-domain cooperative strategy combining "hardware low-pass" and "software comb" filtering, ensuring the precision of signal acquisition. System performance was systematically evaluated using a kainic acid (KA)-induced epilepsy model in ten adult male Sprague-Dawley rats. Signals were acquired under three conditions: independent acquisition (reference baseline), synchronous acquisition without filtering (interference state), and synchronous acquisition with filtering (post-interference suppression). After filtering, the impedance difference between synchronous and independent EIT recordings was only 0.15% under normal conditions and 0.71% during seizures. The reconstructed EIT images achieved a structural similarity index (SSIM) of 0.97 and a Dice coefficient of 0.80. The filtered EEG signals exhibited high similarity to independently recorded signals, with cosine similarity and correlation coefficients both exceeding 0.80 under both normal and epileptic conditions. Spatial consistency analysis revealed that the average deviation between the centroid of the epileptogenic zone localized by EIT and that derived from EEG topography was only 0.13 mm, with a mean relative error of 6.37%. Histological examination confirmed that the regions identified by EIT corresponded to areas exhibiting characteristic epileptic neuronal damage. In 80% of seizures, a sustained impedance decrease (7.48% ± 5.339%) was observed in the focal region, and the area of decreased impedance gradually expanded during seizure progression. These results demonstrate that the system can reliably acquire multimodal signals, accurately localize epileptic foci, and monitor dynamic impedance changes during seizure activity. This study provides a foundational platform for future research on multimodal fusion-based epilepsy diagnosis and the development of portable neural monitoring devices.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Noninvasive Electrical Impedance Tomography for the Monitoring and the Quantification of Tissue Temperature During Liver Cancer Hyperthermia
Accurate non-invasive temperature monitoring during liver tumor hyperthermia remains a significant clinical challenge. This study evaluates the use of electrical impedance tomography (EIT) for quantitative temperature mapping in hepatic thermal therapy by incorporating tissue-specific electrophysiological properties. Based on prior characterization of temperature-dependent electrical conductivity (30–90°C, 1 Hz–1 MHz) in murine hepatocellular carcinoma (HCC) models, computational simulations were developed to demonstrate EIT reconstructed value-temperature correlations. In vivo validation was conducted using orthotopic HCC mice subjected to infrared laser heating (n=6) and radiofrequency ablation (RFA) (n=4), with thermal changes monitored via a custom 16-electrode EIT system operating at 10 kHz. A novel 3D-printed scaffold ensured stable electrode placement on the abdominal surface. Region-of-interest analysis defined tumor, heat affected liver, and distal liver zones. Results revealed strong linear correlations (R²=0.88– 0.93, p<0.0001) between EIT-reconstructed values and thermocouple measured temperatures through tissue-specific temperature-dependent impedance functions. EIT accurately localized thermal lesions and visualized the spatiotemporal evolution of temperature during ablation, with quantification errors of ≤2.8°C (tumor tissue), ≤3.6°C (heated liver tissue), and ≤4.5°C (distal liver tissue), as histologically confirmed. We believe that the technology holds significant potential for improving treatment efficacy in HCC hyperthermia protocols through non-invasive temperature quantification.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Noninvasive Electrical Impedance Tomography for the Monitoring and the Quantification of Tissue Temperature During Liver Cancer Hyperthermia
Accurate non-invasive temperature monitoring during liver tumor hyperthermia remains a significant clinical challenge. This study evaluates the use of electrical impedance tomography (EIT) for quantitative temperature mapping in hepatic thermal therapy by incorporating tissue-specific electrophysiological properties. Based on prior characterization of temperature-dependent electrical conductivity (30–90°C, 1 Hz–1 MHz) in murine hepatocellular carcinoma (HCC) models, computational simulations were developed to demonstrate EIT reconstructed value-temperature correlations. In vivo validation was conducted using orthotopic HCC mice subjected to infrared laser heating (n=6) and radiofrequency ablation (RFA) (n=4), with thermal changes monitored via a custom 16-electrode EIT system operating at 10 kHz. A novel 3D-printed scaffold ensured stable electrode placement on the abdominal surface. Region-of-interest analysis defined tumor, heat affected liver, and distal liver zones. Results revealed strong linear correlations (R²=0.88– 0.93, p<0.0001) between EIT-reconstructed values and thermocouple measured temperatures through tissue-specific temperature-dependent impedance functions. EIT accurately localized thermal lesions and visualized the spatiotemporal evolution of temperature during ablation, with quantification errors of ≤2.8°C (tumor tissue), ≤3.6°C (heated liver tissue), and ≤4.5°C (distal liver tissue), as histologically confirmed. We believe that the technology holds significant potential for improving treatment efficacy in HCC hyperthermia protocols through non-invasive temperature quantification.
- 12 May 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (22) , 225401
Determination of blood dielectric properties based on frequency and blood gas indicators
Blood is a vital component of the human body, and alterations in its dielectric properties can result in changes to the dielectric properties of vital organs and even the entire body. This, in turn, affects the accuracy of bioelectromagnetic techniques such as thoracic electrical bioimpedance, electrical impedance tomography (EIT) and the body composition analysis and body fluid management based on biological impedance measurement. To detect brain damage signals by EIT during cardiopulmonary bypass, where significant alterations in blood composition are observed, it is first necessary to investigate the change of blood dielectric parameters. Accordingly, the purpose of this study is to elucidate the blood dielectric parameters of patients through blood gas indicators and frequency. A correlation analysis was used to ascertain the blood gas indicators that exert a significant influence on the blood dielectric parameters within 10 Hz–100 MHz. Based on these findings, a series of regression models were constructed to determine the dielectric parameters. This study is the first to demonstrate that pH, partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), K+, and Ca2+ concentrations significantly influence blood dielectric properties. The results of the cross-validation and statistical analysis demonstrated that the Gaussian process regression is an effective method for accurately determining the blood dielectric parameters based on blood gas indicators and frequency, with good generalization performance. This finding has the potential to facilitate the effective extraction of brain damage signals by EIT, while also advancing the field of biophysics, biosensors, bioelectromagnetic technology, and electromagnetic modeling of the human body.
- 12 May 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (22) , 225401
Determination of blood dielectric properties based on frequency and blood gas indicators
Blood is a vital component of the human body, and alterations in its dielectric properties can result in changes to the dielectric properties of vital organs and even the entire body. This, in turn, affects the accuracy of bioelectromagnetic techniques such as thoracic electrical bioimpedance, electrical impedance tomography (EIT) and the body composition analysis and body fluid management based on biological impedance measurement. To detect brain damage signals by EIT during cardiopulmonary bypass, where significant alterations in blood composition are observed, it is first necessary to investigate the change of blood dielectric parameters. Accordingly, the purpose of this study is to elucidate the blood dielectric parameters of patients through blood gas indicators and frequency. A correlation analysis was used to ascertain the blood gas indicators that exert a significant influence on the blood dielectric parameters within 10 Hz–100 MHz. Based on these findings, a series of regression models were constructed to determine the dielectric parameters. This study is the first to demonstrate that pH, partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), K+, and Ca2+ concentrations significantly influence blood dielectric properties. The results of the cross-validation and statistical analysis demonstrated that the Gaussian process regression is an effective method for accurately determining the blood dielectric parameters based on blood gas indicators and frequency, with good generalization performance. This finding has the potential to facilitate the effective extraction of brain damage signals by EIT, while also advancing the field of biophysics, biosensors, bioelectromagnetic technology, and electromagnetic modeling of the human body.
- Open Access
- 1 September 2024
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 41 (1) , 2396122
In vivo electrical properties of the healthy liver and the hepatic tumor in a mouse model between 1 Hz and 1 MHz during a thermal treatment
Objective: Understansding the changing patterns of in vivo electrical properties for the target tissue is crucial for the accurate temperature monitoring and the treatment efficacy in thermal therapy. Our research aims to investigate the changing patterns and the reversibility of in vivo electrical properties for both healthy livers and liver tumors in a mouse model over a frequency range of 1 Hz to 1 MHz at temperatures between 30 °C to 90 °C. Methods and materials: The mice were anesthetized and the target organ was exposed. An 808-nm near-infrared laser was employed as the heating source to heat the organ in vivo. The four-needle electrode, connected to an impedance analyzer, was utilized to obtain the impedance at varying temperatures, which were monitored by a thermocouple. Results: The findings indicated a gradual decline in impedance with an increase in temperature. Furthermore, the impedance was normalized to that at 30 °C, and the real part of the normalized impedance was defined as the k-values, which range from 0 to 1. The results demonstrated a linear correlation between k-values and temperatures (R2 > 0.9 for livers and R2 > 0.8 for tumors). Significant differences were observed between livers and tumors at 1, 10 and 50 kHz (p < 0.05). Additionally, it was demonstrated that the electrical properties could be reversed when the temperature was below or equal to 45 °C. Conclusion: We believe that these results will contribute to the advancement of radiofrequency ablation systems and the development of techniques for temperature monitoring during liver thermal treatment.
- 1 September 2024
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 41 (1) , 2396122
Open AccessIn vivo electrical properties of the healthy liver and the hepatic tumor in a mouse model between 1 Hz and 1 MHz during a thermal treatment
Objective: Understansding the changing patterns of in vivo electrical properties for the target tissue is crucial for the accurate temperature monitoring and the treatment efficacy in thermal therapy. Our research aims to investigate the changing patterns and the reversibility of in vivo electrical properties for both healthy livers and liver tumors in a mouse model over a frequency range of 1 Hz to 1 MHz at temperatures between 30 °C to 90 °C. Methods and materials: The mice were anesthetized and the target organ was exposed. An 808-nm near-infrared laser was employed as the heating source to heat the organ in vivo. The four-needle electrode, connected to an impedance analyzer, was utilized to obtain the impedance at varying temperatures, which were monitored by a thermocouple. Results: The findings indicated a gradual decline in impedance with an increase in temperature. Furthermore, the impedance was normalized to that at 30 °C, and the real part of the normalized impedance was defined as the k-values, which range from 0 to 1. The results demonstrated a linear correlation between k-values and temperatures (R2 > 0.9 for livers and R2 > 0.8 for tumors). Significant differences were observed between livers and tumors at 1, 10 and 50 kHz (p < 0.05). Additionally, it was demonstrated that the electrical properties could be reversed when the temperature was below or equal to 45 °C. Conclusion: We believe that these results will contribute to the advancement of radiofrequency ablation systems and the development of techniques for temperature monitoring during liver thermal treatment.
- 1 January 2023
- Published by Clinical Laboratory Publications in Clinical Laboratory
- Vol. 69 (08/2023) , 1715-1721
Effect of Night Shift Work in Clinical Laboratories on Pediatric Complete Blood Count Results
There has been much research into the impact of shift systems on clinicians and nurses, but little research into quality control in clinical laboratories. This topic focuses on assessing the impact of shift systems on clinical laboratory scientists. A total of 34,955 CBCs from pediatric patients who visited the hospital during night-time hours over a period of three years were selected for analysis. The quality of routine blood tests was evaluated using four indica-tors: red blood cell count, white blood cell count, platelet count, and hemoglobin levels. The effects of gender, years of experience, and length of the night shift on test results were evaluated separately for each clinical laboratory scientist. The results showed that the gender and years of experience of the clinical laboratory scientists did not affect the CBC results. However, a significant impact was observed as the number of hours worked on night shifts increased. The findings of this study suggest that the night shift schedule of clinical laboratory scientists can have an impact on the accuracy of pediatric CBCs. It is essential for healthcare institutions to consider the length of night shifts for clinical laboratory scientists and implement measures to minimize the impact on test results.
- 1 January 2023
- Published by Clinical Laboratory Publications in Clinical Laboratory
- Vol. 69 (08/2023) , 1715-1721
Effect of Night Shift Work in Clinical Laboratories on Pediatric Complete Blood Count Results
There has been much research into the impact of shift systems on clinicians and nurses, but little research into quality control in clinical laboratories. This topic focuses on assessing the impact of shift systems on clinical laboratory scientists. A total of 34,955 CBCs from pediatric patients who visited the hospital during night-time hours over a period of three years were selected for analysis. The quality of routine blood tests was evaluated using four indica-tors: red blood cell count, white blood cell count, platelet count, and hemoglobin levels. The effects of gender, years of experience, and length of the night shift on test results were evaluated separately for each clinical laboratory scientist. The results showed that the gender and years of experience of the clinical laboratory scientists did not affect the CBC results. However, a significant impact was observed as the number of hours worked on night shifts increased. The findings of this study suggest that the night shift schedule of clinical laboratory scientists can have an impact on the accuracy of pediatric CBCs. It is essential for healthcare institutions to consider the length of night shifts for clinical laboratory scientists and implement measures to minimize the impact on test results.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Suppressing Interferences of EIT on Synchronous Recording EEG Based on Comb Filter for Seizure Detection
Background and Objective: The purpose of this study was to eliminate the interferences of electrical impedance tomography (EIT) on synchronous recording electroencephalography (EEG) for seizure detection.Methods: The simulated EIT signal generated by COMSOL Multiphysics was superimposed on the clinical EEG signal obtained from the CHB-MIT Scalp EEG Database, and then the spectrum features of superimposed mixed signals were analyzed. According to the spectrum analysis, in addition to high-frequency interference at 51.2 kHz related to the drive current, there was also low-frequency interference caused by switching of electrode pairs, which were used to inject drive current. A low pass filter and a comb filter were used to suppress the high-frequency interference and low-frequency interference, respectively. Simulation results suggested the low-pass filter and comb filter working together effectively filtered out the interference of EIT on EEG in the process of synchronous monitoring.Results: As a result, the normal EEG and epileptic EEG could be recognized effectively. Pearson correlation analysis further confirmed the interference of EIT on EEG was effectively suppressed.Conclusions: The design of the comb filter can be determined by the acquisition frame rate of EIT, without the need to establish the noise template in advance, thus avoiding differences between the template and actual artefact waveforms, which is practical to clinical application. Moreover, this method is robust for different drive patterns and acquisition frame rates of EIT. This study provides a simple and effective interference suppression method for the synchronous monitoring of EIT and EEG, and serves as a reference for the synchronous monitoring of EEG and other medical electromagnetic devices.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessSuppressing Interferences of EIT on Synchronous Recording EEG Based on Comb Filter for Seizure Detection
Background and Objective: The purpose of this study was to eliminate the interferences of electrical impedance tomography (EIT) on synchronous recording electroencephalography (EEG) for seizure detection.Methods: The simulated EIT signal generated by COMSOL Multiphysics was superimposed on the clinical EEG signal obtained from the CHB-MIT Scalp EEG Database, and then the spectrum features of superimposed mixed signals were analyzed. According to the spectrum analysis, in addition to high-frequency interference at 51.2 kHz related to the drive current, there was also low-frequency interference caused by switching of electrode pairs, which were used to inject drive current. A low pass filter and a comb filter were used to suppress the high-frequency interference and low-frequency interference, respectively. Simulation results suggested the low-pass filter and comb filter working together effectively filtered out the interference of EIT on EEG in the process of synchronous monitoring.Results: As a result, the normal EEG and epileptic EEG could be recognized effectively. Pearson correlation analysis further confirmed the interference of EIT on EEG was effectively suppressed.Conclusions: The design of the comb filter can be determined by the acquisition frame rate of EIT, without the need to establish the noise template in advance, thus avoiding differences between the template and actual artefact waveforms, which is practical to clinical application. Moreover, this method is robust for different drive patterns and acquisition frame rates of EIT. This study provides a simple and effective interference suppression method for the synchronous monitoring of EIT and EEG, and serves as a reference for the synchronous monitoring of EEG and other medical electromagnetic devices.