Ruteng Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ruteng Song has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Junyao Li
Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Deterction and Intelligent Perception, Air Force Medical University, Xi’an, China
2 shared publications - Mingxu Zhu
Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Deterction and Intelligent Perception, Air Force Medical University, Xi’an, China
2 shared publications - Wenjing Zhu
School of Life Science and Technology, Northwestern Polytechnical University, Xian, China
2 shared publications - Xuetao Shi
Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
2 shared publications - Yitong Guo
Department of Ultrasound Diagnosis, 3D Printing Research Center, Tangdu Hospital, Air Force Medical University, Xian, China
2 shared publications - Zhenyu Ji
Faculty of Biomedical Engineering, Fourth Military Medical University, Xian, China
2 shared publications
Latest Publications
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Noninvasive Electrical Impedance Tomography for the Monitoring and the Quantification of Tissue Temperature During Liver Cancer Hyperthermia
Accurate non-invasive temperature monitoring during liver tumor hyperthermia remains a significant clinical challenge. This study evaluates the use of electrical impedance tomography (EIT) for quantitative temperature mapping in hepatic thermal therapy by incorporating tissue-specific electrophysiological properties. Based on prior characterization of temperature-dependent electrical conductivity (30–90°C, 1 Hz–1 MHz) in murine hepatocellular carcinoma (HCC) models, computational simulations were developed to demonstrate EIT reconstructed value-temperature correlations. In vivo validation was conducted using orthotopic HCC mice subjected to infrared laser heating (n=6) and radiofrequency ablation (RFA) (n=4), with thermal changes monitored via a custom 16-electrode EIT system operating at 10 kHz. A novel 3D-printed scaffold ensured stable electrode placement on the abdominal surface. Region-of-interest analysis defined tumor, heat affected liver, and distal liver zones. Results revealed strong linear correlations (R²=0.88– 0.93, p<0.0001) between EIT-reconstructed values and thermocouple measured temperatures through tissue-specific temperature-dependent impedance functions. EIT accurately localized thermal lesions and visualized the spatiotemporal evolution of temperature during ablation, with quantification errors of ≤2.8°C (tumor tissue), ≤3.6°C (heated liver tissue), and ≤4.5°C (distal liver tissue), as histologically confirmed. We believe that the technology holds significant potential for improving treatment efficacy in HCC hyperthermia protocols through non-invasive temperature quantification.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Noninvasive Electrical Impedance Tomography for the Monitoring and the Quantification of Tissue Temperature During Liver Cancer Hyperthermia
Accurate non-invasive temperature monitoring during liver tumor hyperthermia remains a significant clinical challenge. This study evaluates the use of electrical impedance tomography (EIT) for quantitative temperature mapping in hepatic thermal therapy by incorporating tissue-specific electrophysiological properties. Based on prior characterization of temperature-dependent electrical conductivity (30–90°C, 1 Hz–1 MHz) in murine hepatocellular carcinoma (HCC) models, computational simulations were developed to demonstrate EIT reconstructed value-temperature correlations. In vivo validation was conducted using orthotopic HCC mice subjected to infrared laser heating (n=6) and radiofrequency ablation (RFA) (n=4), with thermal changes monitored via a custom 16-electrode EIT system operating at 10 kHz. A novel 3D-printed scaffold ensured stable electrode placement on the abdominal surface. Region-of-interest analysis defined tumor, heat affected liver, and distal liver zones. Results revealed strong linear correlations (R²=0.88– 0.93, p<0.0001) between EIT-reconstructed values and thermocouple measured temperatures through tissue-specific temperature-dependent impedance functions. EIT accurately localized thermal lesions and visualized the spatiotemporal evolution of temperature during ablation, with quantification errors of ≤2.8°C (tumor tissue), ≤3.6°C (heated liver tissue), and ≤4.5°C (distal liver tissue), as histologically confirmed. We believe that the technology holds significant potential for improving treatment efficacy in HCC hyperthermia protocols through non-invasive temperature quantification.
- Top Cited Papers
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
A Sparse Bayesian Learning Method for Moving Target Detection and Reconstruction
Moving target detection in the disturbing environment has been significantly active and challenging for underwater acoustic array signal processing. One of the most effective approaches is based on low-rank matrix estimation, which divides the reconstructed imaging frames into low-rank and sparse matrix components, with the low-rank structure representing the interference and the sparse component corresponding to the moving target. However, the array model has not been well explored, taking the reconstruction and moving target separation as independent steps. In this paper, the sparse Bayesian learning (SBL) approach is employed to recover the stable interference and the moving target simultaneously and separately, retaining the high reconstruction quality pertaining to SBL. Specifically, in each frame, a shared prior distribution is assigned to the stable interference, while the time-varying component (the moving target) is modeled with a unique prior distribution. The hierarchical model is solved by the variational Bayesian inference. The superior performance of the proposed algorithm is validated by simulation and experimental data in an underwater acoustic test tank and Songhua Lake in China, compared with state-of-the-art low-rank matrix estimation algorithms.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Top Cited PapersA Sparse Bayesian Learning Method for Moving Target Detection and Reconstruction
Moving target detection in the disturbing environment has been significantly active and challenging for underwater acoustic array signal processing. One of the most effective approaches is based on low-rank matrix estimation, which divides the reconstructed imaging frames into low-rank and sparse matrix components, with the low-rank structure representing the interference and the sparse component corresponding to the moving target. However, the array model has not been well explored, taking the reconstruction and moving target separation as independent steps. In this paper, the sparse Bayesian learning (SBL) approach is employed to recover the stable interference and the moving target simultaneously and separately, retaining the high reconstruction quality pertaining to SBL. Specifically, in each frame, a shared prior distribution is assigned to the stable interference, while the time-varying component (the moving target) is modeled with a unique prior distribution. The hierarchical model is solved by the variational Bayesian inference. The superior performance of the proposed algorithm is validated by simulation and experimental data in an underwater acoustic test tank and Songhua Lake in China, compared with state-of-the-art low-rank matrix estimation algorithms.
- Open Access
- 1 September 2024
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 41 (1) , 2396122
In vivo electrical properties of the healthy liver and the hepatic tumor in a mouse model between 1 Hz and 1 MHz during a thermal treatment
Objective: Understansding the changing patterns of in vivo electrical properties for the target tissue is crucial for the accurate temperature monitoring and the treatment efficacy in thermal therapy. Our research aims to investigate the changing patterns and the reversibility of in vivo electrical properties for both healthy livers and liver tumors in a mouse model over a frequency range of 1 Hz to 1 MHz at temperatures between 30 °C to 90 °C. Methods and materials: The mice were anesthetized and the target organ was exposed. An 808-nm near-infrared laser was employed as the heating source to heat the organ in vivo. The four-needle electrode, connected to an impedance analyzer, was utilized to obtain the impedance at varying temperatures, which were monitored by a thermocouple. Results: The findings indicated a gradual decline in impedance with an increase in temperature. Furthermore, the impedance was normalized to that at 30 °C, and the real part of the normalized impedance was defined as the k-values, which range from 0 to 1. The results demonstrated a linear correlation between k-values and temperatures (R2 > 0.9 for livers and R2 > 0.8 for tumors). Significant differences were observed between livers and tumors at 1, 10 and 50 kHz (p < 0.05). Additionally, it was demonstrated that the electrical properties could be reversed when the temperature was below or equal to 45 °C. Conclusion: We believe that these results will contribute to the advancement of radiofrequency ablation systems and the development of techniques for temperature monitoring during liver thermal treatment.
- 1 September 2024
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 41 (1) , 2396122
Open AccessIn vivo electrical properties of the healthy liver and the hepatic tumor in a mouse model between 1 Hz and 1 MHz during a thermal treatment
Objective: Understansding the changing patterns of in vivo electrical properties for the target tissue is crucial for the accurate temperature monitoring and the treatment efficacy in thermal therapy. Our research aims to investigate the changing patterns and the reversibility of in vivo electrical properties for both healthy livers and liver tumors in a mouse model over a frequency range of 1 Hz to 1 MHz at temperatures between 30 °C to 90 °C. Methods and materials: The mice were anesthetized and the target organ was exposed. An 808-nm near-infrared laser was employed as the heating source to heat the organ in vivo. The four-needle electrode, connected to an impedance analyzer, was utilized to obtain the impedance at varying temperatures, which were monitored by a thermocouple. Results: The findings indicated a gradual decline in impedance with an increase in temperature. Furthermore, the impedance was normalized to that at 30 °C, and the real part of the normalized impedance was defined as the k-values, which range from 0 to 1. The results demonstrated a linear correlation between k-values and temperatures (R2 > 0.9 for livers and R2 > 0.8 for tumors). Significant differences were observed between livers and tumors at 1, 10 and 50 kHz (p < 0.05). Additionally, it was demonstrated that the electrical properties could be reversed when the temperature was below or equal to 45 °C. Conclusion: We believe that these results will contribute to the advancement of radiofrequency ablation systems and the development of techniques for temperature monitoring during liver thermal treatment.