Changzeng Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Changzeng Hu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Lihua Li
College of Mechanical and Electrical Engineering, Hebei Agricultural University, Baoding 071001, China
1 shared publication - Limin Huo
College of Mechanical and Electrical Engineering, Hebei Agricultural University, Baoding 071000, China; Key Laboratory of Broiler/Layer Breeding Facilities Engineering, Ministry of Agriculture and Rural Affairs, Baoding 071000, China; Hebei Provincial Key Laboratory of Livestock and Poultry Breeding Intelligent Equipment and New Energy Utilization, Baoding 071000, China
1 shared publication - Yao Yu
College of Mechanical and Electrical Engineering, Hebei Agricultural University, Baoding 071000, China
1 shared publication - Yuchen Jia
Hebei Agricultural University
1 shared publication - Zongkui Xie
College of Mechanical and Electrical Engineering, Hebei Agricultural University, Baoding 071000, China
1 shared publication
Latest Publications
- Open Access
CFD Investigation on Combined Ventilation System for Multilayer-Caged-Laying Hen Houses
Mechanical ventilation is an important means of environmental control in multitier laying hen cages. The mainstream ventilation mode currently in use, negative-pressure ventilation (NPV), has the drawbacks of a large temperature difference before and after adjustment and uneven air velocity distribution. To solve these problems, this study designed and analyzed a combined positive and negative-pressure ventilation system for laying hen cages. According to the principle of the conservation of mass to increase the inlet flow in the negative-pressure ventilation system on the basis of the addition of the pressure-wind body-built positive-and-negative-pressure-combined ventilation (PNCV) system, further, computational fluid dynamics (CFD) simulation was performed to analyze the distribution of environmental parameters in the chicken cage zone (CZ) with inlet angles of positive-pressure fans set at 45°, 90°, and 30°. Simulation results showed that the PNCV system increased the average air velocity in the CZ from 0.94 m/s to 1.04 m/s, 1.28 m/s, and 0.99 m/s by actively blowing air into the cage. The maximum temperature difference in the CZ with the PNCV system was 2.91 °C, 1.80 °C, and 3.78 °C, which were all lower than 4.46 °C, the maximum temperature difference in the CZ with the NPV system. Moreover, the relative humidity remained below 80% for the PNCV system and between 80% and 85% for the NPV system. Compared with the NPV system, the PNCV system increased the vertical airflow movement, causing significant cooling and dehumidifying effects. Hence, the proposed system provides an effective new ventilation mode for achieving efficient and accurate environmental control in laying hen cages.
Open AccessCFD Investigation on Combined Ventilation System for Multilayer-Caged-Laying Hen Houses
Mechanical ventilation is an important means of environmental control in multitier laying hen cages. The mainstream ventilation mode currently in use, negative-pressure ventilation (NPV), has the drawbacks of a large temperature difference before and after adjustment and uneven air velocity distribution. To solve these problems, this study designed and analyzed a combined positive and negative-pressure ventilation system for laying hen cages. According to the principle of the conservation of mass to increase the inlet flow in the negative-pressure ventilation system on the basis of the addition of the pressure-wind body-built positive-and-negative-pressure-combined ventilation (PNCV) system, further, computational fluid dynamics (CFD) simulation was performed to analyze the distribution of environmental parameters in the chicken cage zone (CZ) with inlet angles of positive-pressure fans set at 45°, 90°, and 30°. Simulation results showed that the PNCV system increased the average air velocity in the CZ from 0.94 m/s to 1.04 m/s, 1.28 m/s, and 0.99 m/s by actively blowing air into the cage. The maximum temperature difference in the CZ with the PNCV system was 2.91 °C, 1.80 °C, and 3.78 °C, which were all lower than 4.46 °C, the maximum temperature difference in the CZ with the NPV system. Moreover, the relative humidity remained below 80% for the PNCV system and between 80% and 85% for the NPV system. Compared with the NPV system, the PNCV system increased the vertical airflow movement, causing significant cooling and dehumidifying effects. Hence, the proposed system provides an effective new ventilation mode for achieving efficient and accurate environmental control in laying hen cages.