Zhuoyang Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhuoyang Han has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Yinping Miao
School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin, China
3 shared publications - Xuanyi Chen
Tianjin Key Laboratory of Film Electronic and Communication Device, School of Integrated Circuit Science and Engineering, Tianjin University of Technology , Tianjin 300384
2 shared publications - Yangyuan Zhang
Tianjin Key Laboratory of Film Electronic and Communication Device, School of Integrated Circuit Science and Engineering, Tianjin University of Technology 1 , Tianjin 300384, China
2 shared publications - Changping Xu
Tianjin Key Laboratory of Film Electronic and Communication Device, School of Integrated Circuit Science and Engineering, Tianjin University of Technology , Tianjin 300384
1 shared publication Jianquan Yao
College of Precision Instrument and Optoelectronics Engineering, Institute of Laser and Opto-Electronics, Tianjin University 2 , Tianjin 300072, China
1 shared publicationShouchuan Guo
Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin, China
1 shared publication
Latest Publications
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (5) , 6785-6791
Polymer-Integrated Fiber Parallel Fabry–Perot Cavity Sensor Based on Ti 3 C 2 T x MXene-Enhanced Photothermal Effect for Myoglobin Detection
Acute myocardial infarction (AMI) is one of the leading causes of death in most developing and developed countries worldwide. As an important biomarker for the early diagnosis of AMI, myoglobin (Mb) renders the development of rapid and accurate detection technologies for it of great research signifi-cance. This paper proposes a parallel optical fiber Fabry-Perot (FP) cavity biosensor using polydimethylsiloxane (PDMS) as the functional cavity and Ti3C2Tx MXene as the sensitizing material. PDMS has an extremely high thermal expansion coefficient, enabling it to convert the thermal signal generated by Mb under 405 nm laser irradiation into a change in cavity length. Ti3C2Tx MXene can enhance the adsorption capacity of the sensing tip for Mb molecules. Paralleling two FP cavities with similar structures but different cavity lengths creates a Vernier effect, which can amplify spectral drift. Experimental results show that the sensor achieves a sensitivity of 4.515 nm/(mg/L) in the concentration range of 0.0001–10 mg/L, with a limit of detection (LOD) of 4.429 ng/ml. The proposed sensor features high sensitivity, a wide detection range, and strong robustness, with a detection time as short as 15 seconds. It holds potential application value in the field of early and rapid diagnosis of acute myocardial infarction.
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (5) , 6785-6791
Polymer-Integrated Fiber Parallel Fabry–Perot Cavity Sensor Based on Ti 3 C 2 T x MXene-Enhanced Photothermal Effect for Myoglobin Detection
Acute myocardial infarction (AMI) is one of the leading causes of death in most developing and developed countries worldwide. As an important biomarker for the early diagnosis of AMI, myoglobin (Mb) renders the development of rapid and accurate detection technologies for it of great research signifi-cance. This paper proposes a parallel optical fiber Fabry-Perot (FP) cavity biosensor using polydimethylsiloxane (PDMS) as the functional cavity and Ti3C2Tx MXene as the sensitizing material. PDMS has an extremely high thermal expansion coefficient, enabling it to convert the thermal signal generated by Mb under 405 nm laser irradiation into a change in cavity length. Ti3C2Tx MXene can enhance the adsorption capacity of the sensing tip for Mb molecules. Paralleling two FP cavities with similar structures but different cavity lengths creates a Vernier effect, which can amplify spectral drift. Experimental results show that the sensor achieves a sensitivity of 4.515 nm/(mg/L) in the concentration range of 0.0001–10 mg/L, with a limit of detection (LOD) of 4.429 ng/ml. The proposed sensor features high sensitivity, a wide detection range, and strong robustness, with a detection time as short as 15 seconds. It holds potential application value in the field of early and rapid diagnosis of acute myocardial infarction.
- 24 February 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (8)
Polymer-integrated optical fiber Fabry–Pérot interferometer with Vernier effect for the detection of myoglobin
Acute myocardial infarction (AMI) is the most severe manifestation of coronary artery disease and one of the leading causes of morbidity and mortality worldwide. The concentration of myoglobin (Mb) in serum has been regarded as an essential indicator for the early diagnosis of AMI. Developing a rapid, sensitive, and accurate Mb detection method is very important for the early diagnosis of AMI. This study reports a fiber optic biosensor based on polymer and Vernier effect composite sensitization for real-time detection of serum Mb concentration. The sensor is made of a Fabry–Pérot interferometer cascade tapered microfiber filled with photothermal material polydimethylsiloxane. Two interference structures with similar but unequal free spectral range are combined, and the superposition spectrum produces periodic interference fringes, forming a fiber sensor with a Vernier effect. By detecting the photothermal signal generated by the absorption of light by Mb, marker-free, specific detection can be achieved. The sensing device attained a sensitivity of 5.235 nm/(mg/L) in the 0.0001–10 mg/L concentration range. The linearity reached 0.9978, with a limit of detection of 3.82 ng/ml, which meets the sensitivity requirements for detecting Mb concentration in serum, and the detection time was less than 40 s, which has potential in the early diagnosis of related diseases.
- 24 February 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (8)
Polymer-integrated optical fiber Fabry–Pérot interferometer with Vernier effect for the detection of myoglobin
Acute myocardial infarction (AMI) is the most severe manifestation of coronary artery disease and one of the leading causes of morbidity and mortality worldwide. The concentration of myoglobin (Mb) in serum has been regarded as an essential indicator for the early diagnosis of AMI. Developing a rapid, sensitive, and accurate Mb detection method is very important for the early diagnosis of AMI. This study reports a fiber optic biosensor based on polymer and Vernier effect composite sensitization for real-time detection of serum Mb concentration. The sensor is made of a Fabry–Pérot interferometer cascade tapered microfiber filled with photothermal material polydimethylsiloxane. Two interference structures with similar but unequal free spectral range are combined, and the superposition spectrum produces periodic interference fringes, forming a fiber sensor with a Vernier effect. By detecting the photothermal signal generated by the absorption of light by Mb, marker-free, specific detection can be achieved. The sensing device attained a sensitivity of 5.235 nm/(mg/L) in the 0.0001–10 mg/L concentration range. The linearity reached 0.9978, with a limit of detection of 3.82 ng/ml, which meets the sensitivity requirements for detecting Mb concentration in serum, and the detection time was less than 40 s, which has potential in the early diagnosis of related diseases.
- 9 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (11)
Low detection limit of uric acid based on Prussian blue-enhanced photothermal effect with microfiber knot resonator
The human serum uric acid (UA) level is a crucial indicator for diagnosing dementia in middle-aged and elderly individuals, with decreased levels being expressed in patients. Therefore, developing a high-performance sensor for online uric acid detection is of significant research interest. Herein, a microfiber knot resonator (MKR) sensor for quantitative detection of UA levels is reported. Combining polydimethylsiloxane (PDMS) with an adiabatic MKR, the specificity of UA detection in serum is improved using the photothermal effect of Prussian blue-enhanced uricase reaction. During the sensor operation, UA generates the photothermal effect under 650 nm laser irradiation, causing the PDMS film to expand with heat absorption, thereby shifting the resonance spectrum of the PDMS-MKR sensor. Experimental results demonstrate a sensitivity of 0.0559 nm/(μmol/L) within a UA concentration range of 40–120 μmol/L and a detection limit as low as 0.3578 μmol/L. The proposed sensor shows potential applications in clinical point-of-care early diagnosis and prognosis of dementia due to its specificity, fast detection speed, robustness, and high integration.
- 9 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (11)
Low detection limit of uric acid based on Prussian blue-enhanced photothermal effect with microfiber knot resonator
The human serum uric acid (UA) level is a crucial indicator for diagnosing dementia in middle-aged and elderly individuals, with decreased levels being expressed in patients. Therefore, developing a high-performance sensor for online uric acid detection is of significant research interest. Herein, a microfiber knot resonator (MKR) sensor for quantitative detection of UA levels is reported. Combining polydimethylsiloxane (PDMS) with an adiabatic MKR, the specificity of UA detection in serum is improved using the photothermal effect of Prussian blue-enhanced uricase reaction. During the sensor operation, UA generates the photothermal effect under 650 nm laser irradiation, causing the PDMS film to expand with heat absorption, thereby shifting the resonance spectrum of the PDMS-MKR sensor. Experimental results demonstrate a sensitivity of 0.0559 nm/(μmol/L) within a UA concentration range of 40–120 μmol/L and a detection limit as low as 0.3578 μmol/L. The proposed sensor shows potential applications in clinical point-of-care early diagnosis and prognosis of dementia due to its specificity, fast detection speed, robustness, and high integration.