Amr Anos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Amr Anos has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Christina Botrous
Department of Cardiology, Bristol Heart Institute, University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, England
2 shared publications - Janaka Pathiraja
Gloucestershire Hospitals Foundation Trust, Cheltenham General Hospital, Sandford Road, Cheltenham GL53 7AN, UK
2 shared publications - Kai Hogrefe
Kettering General Hospitals, Rothwell Road, Kettering NN16 8UZ, UK
2 shared publications - Mina Ibrahim
Bristol Royal Infirmary, Upper Maudlin Street, Bristol BS2 8HW, UK
2 shared publications - Nancy Zaher Kelada Wassef
Gloucestershire Hospitals Foundation Trust, Cheltenham, United Kingdom
2 shared publications
Latest Publications
- Open Access
- 5 November 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (22) , 2465
Dual Chamber Pacemaker Implant in Coronary Sinus Leading to Several Complications
Permanent pacemaker implantation is a low-risk procedure. However, complications may occur at a rate of around 4–8%. We present a case where initial implantation resulted in complications that could have been avoided by meticulous assessment of lead position in different projections and early post-procedure X-ray that would have delineated other serious complications. We present a case where the right ventricular lead was placed in the coronary sinus, which resulted in the loss of pacing capture with further syncope after the pacemaker implant. This was apparent in the post-procedure electrocardiogram (ECG) with right bundle branch pacing and the lead was repositioned in the right ventricular apex the following day. Furthermore, the patient was discharged home without a chest X-ray (CXR), and she represented a week later with a haemo-pneumothorax and pericardial effusion. A chest drain was placed and was discharged after a slow recovery following several complications that could have been avoidable.
- 5 November 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (22) , 2465
Open AccessDual Chamber Pacemaker Implant in Coronary Sinus Leading to Several Complications
Permanent pacemaker implantation is a low-risk procedure. However, complications may occur at a rate of around 4–8%. We present a case where initial implantation resulted in complications that could have been avoided by meticulous assessment of lead position in different projections and early post-procedure X-ray that would have delineated other serious complications. We present a case where the right ventricular lead was placed in the coronary sinus, which resulted in the loss of pacing capture with further syncope after the pacemaker implant. This was apparent in the post-procedure electrocardiogram (ECG) with right bundle branch pacing and the lead was repositioned in the right ventricular apex the following day. Furthermore, the patient was discharged home without a chest X-ray (CXR), and she represented a week later with a haemo-pneumothorax and pericardial effusion. A chest drain was placed and was discharged after a slow recovery following several complications that could have been avoidable.
- Open Access
- 30 September 2024
- Published by MDPI AG in Preprints.org
Dual Chamber Pacemaker Implant in Coronary Sinus with Several Complications
Permanent pacemaker implantation is a low-risk procedure. However, complications may occur with a rate of around 3-8%. We present a case where initial implantation resulted in complications that could have been avoided by meticulous assessment of lead position in different projections and early post procedure X-ray that would have delineated other serious complications. An eighty-seven-year-old female patient presented with syncope and documented high grade atrioventricular block. She had a dual chamber pacemaker implant, after which she had another episode of syncope with loss of pacing capture. This was rectified by ventricular lead repositioning that resulted in consistent ventricular pacing. A week later, she was re-admitted with worsening dyspnoea and fatigue. Chest X-ray (CXR) and CT revealed haemopericardium and haemothorax and she was treated with a chest drain and conservatively managed for pericardial effusion. She had a slow recovery and was discharged home after treatment with no further symptoms during follow up in pacing clinic. This case emphasises the importance of meticulous assessment during and after pacemaker implantation.
- 30 September 2024
- Published by MDPI AG in Preprints.org
Open AccessDual Chamber Pacemaker Implant in Coronary Sinus with Several Complications
Permanent pacemaker implantation is a low-risk procedure. However, complications may occur with a rate of around 3-8%. We present a case where initial implantation resulted in complications that could have been avoided by meticulous assessment of lead position in different projections and early post procedure X-ray that would have delineated other serious complications. An eighty-seven-year-old female patient presented with syncope and documented high grade atrioventricular block. She had a dual chamber pacemaker implant, after which she had another episode of syncope with loss of pacing capture. This was rectified by ventricular lead repositioning that resulted in consistent ventricular pacing. A week later, she was re-admitted with worsening dyspnoea and fatigue. Chest X-ray (CXR) and CT revealed haemopericardium and haemothorax and she was treated with a chest drain and conservatively managed for pericardial effusion. She had a slow recovery and was discharged home after treatment with no further symptoms during follow up in pacing clinic. This case emphasises the importance of meticulous assessment during and after pacemaker implantation.