B. I. Buschmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
B. I. Buschmann has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Maria Gatu Johnson
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
13 shared publications - Johan A. Frenje
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
10 shared publications - Justin Haruaki Kunimune
Massachusetts Institute of Technology 3 , Cambridge, Massachusetts 02139
10 shared publications - B. C. Foo
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
9 shared publications - Christopher Wink
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
9 shared publications - Joseph Vargas
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
9 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Evaluation of the high-performance TechnoTrak CR-39 for detection of 1–9 MeV fusion protons
In this paper, the MeV-proton response of a high-sensitivity, low-noise CR-39 nuclear track detector, TechnoTrak, produced by the Chiyoda Technol Corporation, is evaluated. Plastic CR-39 nuclear track detectors are commonly used for precise time-integrated measurement of charged particles. Such measurements are crucial for diagnosing inertial confinement fusion (ICF) and high energy density (HED) experiments at the Omega Laser Facility, the Z Pulsed Power Facility, and the National Ignition Facility. The response of TechnoTrak CR-39 detectors was tested with protons produced from DD and D3He fusion reactions at the MIT linear ion accelerator. The results indicate that TechnoTrak CR-39 detectors exhibit high detection efficiency over a wide proton energy range (∼1−5 MeV), remain sensitive to protons up to ∼9 MeV, and have lower intrinsic noise than widely used TASTRAKTM CR-39 produced by Track Analysis Systems Ltd. This wide detectable energy range and low noise floor may benefit future HED and ICF experiments requiring low background levels and broad proton energy sensitivity.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessEvaluation of the high-performance TechnoTrak CR-39 for detection of 1–9 MeV fusion protons
In this paper, the MeV-proton response of a high-sensitivity, low-noise CR-39 nuclear track detector, TechnoTrak, produced by the Chiyoda Technol Corporation, is evaluated. Plastic CR-39 nuclear track detectors are commonly used for precise time-integrated measurement of charged particles. Such measurements are crucial for diagnosing inertial confinement fusion (ICF) and high energy density (HED) experiments at the Omega Laser Facility, the Z Pulsed Power Facility, and the National Ignition Facility. The response of TechnoTrak CR-39 detectors was tested with protons produced from DD and D3He fusion reactions at the MIT linear ion accelerator. The results indicate that TechnoTrak CR-39 detectors exhibit high detection efficiency over a wide proton energy range (∼1−5 MeV), remain sensitive to protons up to ∼9 MeV, and have lower intrinsic noise than widely used TASTRAKTM CR-39 produced by Track Analysis Systems Ltd. This wide detectable energy range and low noise floor may benefit future HED and ICF experiments requiring low background levels and broad proton energy sensitivity.
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Impact of instrumental effects and target thickness on the SPARC magnetic proton recoil spectrometer response function
The SPARC tokamak aims to demonstrate net fusion power gain in tokamaks (Q-fus > 1). To measure neutron emission, a neutron spectrometer based on the magnetic proton recoil technique is being developed. This diagnostic operates by converting collimated neutrons into recoil protons through elastic scattering on a polyethylene target. The recoiled protons are then separated based on their momentum by a magnetic field and subsequently detected by a hodoscope composed of plastic scintillation detectors coupled to photomultiplier tubes. This allows neutron energies in the 2–20 MeV range to be discriminated, though only neutrons in a narrower energy window (±25% around the selected central energy) can be measured. The instrument will contribute to the determination of the total fusion power and provide information on plasma parameters such as ion temperature and the presence of non-thermal fuel ions. In this study, the design rationale of the hodoscope is presented and the main instrumental effects that govern proton collection are characterized. The hodoscope is divided into three regions with different channel widths, depths, and lengths, jointly optimized to satisfy three coupled physical requirements: sufficient energy resolution at the 14.1 MeV DT peak, full proton containment up to 18.75 MeV, and limitation of the background through minimization of the detector volume. Three correction factors are evaluated through dedicated simulations: the vertical signal loss due to protons falling outside the scintillator rod length, the cross-talk between adjacent channels, and the background contribution per channel. A correction scheme combining all three factors is presented.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessImpact of instrumental effects and target thickness on the SPARC magnetic proton recoil spectrometer response function
The SPARC tokamak aims to demonstrate net fusion power gain in tokamaks (Q-fus > 1). To measure neutron emission, a neutron spectrometer based on the magnetic proton recoil technique is being developed. This diagnostic operates by converting collimated neutrons into recoil protons through elastic scattering on a polyethylene target. The recoiled protons are then separated based on their momentum by a magnetic field and subsequently detected by a hodoscope composed of plastic scintillation detectors coupled to photomultiplier tubes. This allows neutron energies in the 2–20 MeV range to be discriminated, though only neutrons in a narrower energy window (±25% around the selected central energy) can be measured. The instrument will contribute to the determination of the total fusion power and provide information on plasma parameters such as ion temperature and the presence of non-thermal fuel ions. In this study, the design rationale of the hodoscope is presented and the main instrumental effects that govern proton collection are characterized. The hodoscope is divided into three regions with different channel widths, depths, and lengths, jointly optimized to satisfy three coupled physical requirements: sufficient energy resolution at the 14.1 MeV DT peak, full proton containment up to 18.75 MeV, and limitation of the background through minimization of the detector volume. Three correction factors are evaluated through dedicated simulations: the vertical signal loss due to protons falling outside the scintillator rod length, the cross-talk between adjacent channels, and the background contribution per channel. A correction scheme combining all three factors is presented.
- Open Access
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
The next-generation magnetic recoil spectrometer for measurements of the absolute neutron spectrum at Pacific Fusion’s demonstration system
The MAgnetic Recoil Spectrometer (MARS) will be used to diagnose neutron spectra from deuterium–tritium fusion experiments at Pacific Fusion’s demonstration system, providing time-integrated measurements of yield (13–15 MeV), ion temperature, fuel and liner areal density, and alpha heating. Two design advances distinguish MARS from prior magnetic recoil spectrometers. First, redesigned ion optics reduce the focal-plane length to a size compatible with a silicon strip detector, making MARS the first inertial confinement fusion magnetic recoil neutron spectrometer with an electronic readout, enabling real-time data analysis and per-channel time-gating. Second, a dual-foil geometry (half CH2, half CD2) enables simultaneous spectral measurements of recoil protons and deuterons in a single shot, expanding neutron energy coverage to ∼6–20 MeV. The conceptual design of the instrument, synthetic modeling framework, and shielding strategy are described. Monte Carlo transport and ion optics simulations show signal-to-background ≫10 across the spectrum except for the alpha knock-on tail, with per-channel electronic time-gating providing additional background suppression. The open-source simulation framework additionally serves as a synthetic diagnostic for forward fits of parametric plasma models, showing good agreement with the true parameters.
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Open AccessThe next-generation magnetic recoil spectrometer for measurements of the absolute neutron spectrum at Pacific Fusion’s demonstration system
The MAgnetic Recoil Spectrometer (MARS) will be used to diagnose neutron spectra from deuterium–tritium fusion experiments at Pacific Fusion’s demonstration system, providing time-integrated measurements of yield (13–15 MeV), ion temperature, fuel and liner areal density, and alpha heating. Two design advances distinguish MARS from prior magnetic recoil spectrometers. First, redesigned ion optics reduce the focal-plane length to a size compatible with a silicon strip detector, making MARS the first inertial confinement fusion magnetic recoil neutron spectrometer with an electronic readout, enabling real-time data analysis and per-channel time-gating. Second, a dual-foil geometry (half CH2, half CD2) enables simultaneous spectral measurements of recoil protons and deuterons in a single shot, expanding neutron energy coverage to ∼6–20 MeV. The conceptual design of the instrument, synthetic modeling framework, and shielding strategy are described. Monte Carlo transport and ion optics simulations show signal-to-background ≫10 across the spectrum except for the alpha knock-on tail, with per-channel electronic time-gating providing additional background suppression. The open-source simulation framework additionally serves as a synthetic diagnostic for forward fits of parametric plasma models, showing good agreement with the true parameters.
- 14 August 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 232
Characterization of a prototype parallel-plate 238U fission chamber with DD and DT fusion neutron sources
- 14 August 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 232
Characterization of a prototype parallel-plate 238U fission chamber with DD and DT fusion neutron sources
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Design of an in-vacuum manipulator for nuclear diagnostics development at the MIT linear electrostatic ion accelerator
An ultrahigh vacuum compatible manipulator known as the Diagnostic Manipulating Element (DiME) has been developed for the MIT Linear Electrostatic Ion Accelerator (LEIA) facility. The system was designed to reduce the resources dedicated toward the calibration process for step-range filters CR-39 based proton spectrometers used in inertial confinement fusion experiments at the Lawrence Livermore National Ignition Facility and the University of Rochester’s OMEGA Laser Facility. To accurately account for variations in nominal filter thicknesses when analyzing experimental data, the spectrometers are calibrated at the MIT LEIA facility prior to use at other facilities. The system supports rapid prototyping and can reduce the time necessary for spectrometer calibration by 50%. The modular design of the DiME is described in this article to facilitate the implementation of similar design methods at other facilities focused on the development of nuclear fusion technologies.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Design of an in-vacuum manipulator for nuclear diagnostics development at the MIT linear electrostatic ion accelerator
An ultrahigh vacuum compatible manipulator known as the Diagnostic Manipulating Element (DiME) has been developed for the MIT Linear Electrostatic Ion Accelerator (LEIA) facility. The system was designed to reduce the resources dedicated toward the calibration process for step-range filters CR-39 based proton spectrometers used in inertial confinement fusion experiments at the Lawrence Livermore National Ignition Facility and the University of Rochester’s OMEGA Laser Facility. To accurately account for variations in nominal filter thicknesses when analyzing experimental data, the spectrometers are calibrated at the MIT LEIA facility prior to use at other facilities. The system supports rapid prototyping and can reduce the time necessary for spectrometer calibration by 50%. The modular design of the DiME is described in this article to facilitate the implementation of similar design methods at other facilities focused on the development of nuclear fusion technologies.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Impact of x rays on the sensitivity of CR-39 detectors to 2.4-MeV protons
Solid-state nuclear track detectors, such as CR-39, lose sensitivity when subjected to doses of x rays on the order of 1 Gy in nuclear-fusion relevant experiments. As a result, the formed tracks have, in general, smaller maximum radii and shallower maximum depths. Presented here are experiments using atomic force microscopy to measure the CR-39 sensitivity parameter Vt/Vb, the ratio of track to bulk etch rates, for ∼2.4 MeV protons. The measurements revealed that absorbed x-ray doses of the order of 1 Gy reduced the CR-39 track diameters by a factor of 3 from ∼1200 to ∼400 nm and reduced the track depths by an order of magnitude from ∼550 to ∼50 nm. The corresponding change in the sensitivity parameter was inferred and found to have substantially decreased from ∼1.1 to ≲1.01. Doses in excess of 0.5 Gy reduced the track diameter, at an etch time of 2 h, below the 1.0 μm limit typical of optical microscopy methods used when scanning large, i.e., ≳25 cm2, samples of CR-39. The findings suggest that the mechanism of sensitivity loss is driven by x-ray induced cross-linking of the bulk CR-39. The enhanced cross-linking reduces the solubility of the material along charged-particle trajectories compared with that of the bulk material. Representative absorbed doses of between 0.01 and 1 Gy in CR-39 on OMEGA and NIF in typical experimental configurations are then compared with the results.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Impact of x rays on the sensitivity of CR-39 detectors to 2.4-MeV protons
Solid-state nuclear track detectors, such as CR-39, lose sensitivity when subjected to doses of x rays on the order of 1 Gy in nuclear-fusion relevant experiments. As a result, the formed tracks have, in general, smaller maximum radii and shallower maximum depths. Presented here are experiments using atomic force microscopy to measure the CR-39 sensitivity parameter Vt/Vb, the ratio of track to bulk etch rates, for ∼2.4 MeV protons. The measurements revealed that absorbed x-ray doses of the order of 1 Gy reduced the CR-39 track diameters by a factor of 3 from ∼1200 to ∼400 nm and reduced the track depths by an order of magnitude from ∼550 to ∼50 nm. The corresponding change in the sensitivity parameter was inferred and found to have substantially decreased from ∼1.1 to ≲1.01. Doses in excess of 0.5 Gy reduced the track diameter, at an etch time of 2 h, below the 1.0 μm limit typical of optical microscopy methods used when scanning large, i.e., ≳25 cm2, samples of CR-39. The findings suggest that the mechanism of sensitivity loss is driven by x-ray induced cross-linking of the bulk CR-39. The enhanced cross-linking reduces the solubility of the material along charged-particle trajectories compared with that of the bulk material. Representative absorbed doses of between 0.01 and 1 Gy in CR-39 on OMEGA and NIF in typical experimental configurations are then compared with the results.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Errors in the field reconstruction using CR-39 proton radiographs with high fluence variation
CR-39 proton radiography is an experimental charged-particle backlighter platform fielded and used at OMEGA and the NIF to image electric and magnetic fields in a subject plasma. Processing a piece of CR-39 involves etching it in hot NaOH, and the etch time can greatly impact the background-to-signal ratio (BSR) in low-fluence (≲4 × 104 cm−2) regions and detection efficiency in high-fluence regions (≳7 × 105 cm−2). For CR-39 data with high fluence variation, these effects mean that any single etch time will result in ≳15% error in the measured signal in either the high- or low-fluence regions. This study aims to quantify the impact of the etch time on the BSR and efficiency losses and how these affect the field reconstruction. Experiments at the MIT Linear Electrostatic Ion Accelerator provided empirical values of the BSR and efficiency losses as a function of the fluence and etch time for fluences ranging from 3 × 103 to 7 × 105 cm−2. Synthetic radiographs were generated with known fields and modulated based on empirical values of BSR and efficiency losses. The fields were reconstructed using a Monge–Ampère code with the modulated radiographs as input. The results indicate that combining short and long etches allows for more accurate analysis of radiographs with high fluence variation, with the mean squared error of the reconstructed fields decreasing by factors of 1.2–7 compared to the reconstructions using only one etch time.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessErrors in the field reconstruction using CR-39 proton radiographs with high fluence variation
CR-39 proton radiography is an experimental charged-particle backlighter platform fielded and used at OMEGA and the NIF to image electric and magnetic fields in a subject plasma. Processing a piece of CR-39 involves etching it in hot NaOH, and the etch time can greatly impact the background-to-signal ratio (BSR) in low-fluence (≲4 × 104 cm−2) regions and detection efficiency in high-fluence regions (≳7 × 105 cm−2). For CR-39 data with high fluence variation, these effects mean that any single etch time will result in ≳15% error in the measured signal in either the high- or low-fluence regions. This study aims to quantify the impact of the etch time on the BSR and efficiency losses and how these affect the field reconstruction. Experiments at the MIT Linear Electrostatic Ion Accelerator provided empirical values of the BSR and efficiency losses as a function of the fluence and etch time for fluences ranging from 3 × 103 to 7 × 105 cm−2. Synthetic radiographs were generated with known fields and modulated based on empirical values of BSR and efficiency losses. The fields were reconstructed using a Monge–Ampère code with the modulated radiographs as input. The results indicate that combining short and long etches allows for more accurate analysis of radiographs with high fluence variation, with the mean squared error of the reconstructed fields decreasing by factors of 1.2–7 compared to the reconstructions using only one etch time.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Quantifying the effects of neutron fluence on proton signal retention in CR-39
This paper reports on investigations on the impact of higher neutron fluences on the detection efficiency of protons with CR-39, a charged particle track detector. CR-39 is widely used as a diagnostic for inertial fusion applications and is an integral component of numerous particle diagnostics at the OMEGA laser facility and National Ignition Facility. As experiments continue to produce higher and higher yields, existing diagnostics are impacted by higher particle fluences than they were originally designed for. This paper presents data from experiments measuring proton signal on pieces of CR-39 with different levels of neutron fluence with two different etch times. The experiments show a decrease in signal recovery with increased neutron fluence, which is exacerbated at longer etch times. At 3 h etch time, data suggest a 17% ± 7% signal loss at 1.3 × 105 neutron-induced tracks per cm2 and a 67% ± 21% loss at 6 h etch time. Careful signal isolation techniques can recover most of the proton tracks even with moderate neutron fluence.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessQuantifying the effects of neutron fluence on proton signal retention in CR-39
This paper reports on investigations on the impact of higher neutron fluences on the detection efficiency of protons with CR-39, a charged particle track detector. CR-39 is widely used as a diagnostic for inertial fusion applications and is an integral component of numerous particle diagnostics at the OMEGA laser facility and National Ignition Facility. As experiments continue to produce higher and higher yields, existing diagnostics are impacted by higher particle fluences than they were originally designed for. This paper presents data from experiments measuring proton signal on pieces of CR-39 with different levels of neutron fluence with two different etch times. The experiments show a decrease in signal recovery with increased neutron fluence, which is exacerbated at longer etch times. At 3 h etch time, data suggest a 17% ± 7% signal loss at 1.3 × 105 neutron-induced tracks per cm2 and a 67% ± 21% loss at 6 h etch time. Careful signal isolation techniques can recover most of the proton tracks even with moderate neutron fluence.
- Open Access
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Image plate multi-scan response to fusion protons in the range of 1–14 MeV
Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Open AccessImage plate multi-scan response to fusion protons in the range of 1–14 MeV
Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.