SPS. Portero

S. Portero

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


S. Portero has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Below 100 ps CTR using FastIC+, an ASIC including on-chip digitization for ToF-PET and beyond

    by D. Mazzanti, S. Gómez, J. Mauricio, J. Alozy, F. Bandi, M. Campbell, R. Dolenec, G. El Fakhri, J. M. Fernández-Tenllado, A. Gola, et al.

    This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This ASIC, manufactured in 65 nm CMOS technology, can readout positive or negative polarity sensors and provides a digitized measurement of the arrival time and energy of the detected events with a power consumption of 12.5 mW per channel. On-chip digitization is executed by a Time-to-Digital Converter (TDC) based on a Phase-Locked Loop (PLL) generating 16 phases at 1.28 GHz. The internal TDC introduces a jitter contribution of 31.3 ps FWHM, with minimal impact on timing measurements. When evaluating FastIC+ to readout 3×3 mm2 silicon photomultipliers (SiPMs) with a pulsed laser, we achieved a single-photon time resolution (SPTR) of (98 ± 1) ps FWHM.We also performed time-of-flight positron emission tomography (ToF-PET) experiments using scintillator crystals of different sizes and materials. With LYSO:Ce,Ca crystals of 2.8×2.8×20 mm3 we obtained a coincidence time resolution (CTR) of (130 ± 1) ps FWHM. With LGSO crystals of 2×2×3 mm3, a CTR of (85 ± 1) ps FWHM. To the best of our knowledge, this is the first time that a CTR below 100 ps using on-chip digitization is reported.


  • Open Access

    Below 100 ps CTR using FastIC+, an ASIC including on-chip digitization for ToF-PET and beyond

    by D. Mazzanti, S. Gomez, J. Mauricio, J. Alozy, F. Bandi, M. Campbell, R. Dolenec, G. El Fakhri, J. M. Fernandez-Tenllado, A. Gola, et al.

    This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This ASIC, manufactured in 65 nm CMOS technology, can readout positive or negative polarity sensors and provides a digitized measurement of the arrival time and energy of the detected events with a power consumption of 12.5 mW per channel. On-chip digitization is executed by a Time-to-Digital Converter (TDC) based on a Phase-Locked Loop (PLL) generating 16 phases at 1.28 GHz. The internal TDC introduces a jitter contribution of 31.3 ps FWHM, with minimal impact on timing measurements. When evaluating FastIC+ to readout 3$\times$3 mm$^2$ silicon photomultipliers (SiPMs) with a pulsed laser, we achieved a single-photon time resolution (SPTR) of (98 $\pm$ 1) ps FWHM. We also performed time-of-flight positron emission tomography (ToF-PET) experiments using scintillator crystals of different sizes and materials. With LYSO:Ce,Ca crystals of 2.8$\times$2.8$\times$20 mm$^3$ we obtained a coincidence time resolution (CTR) of (130 $\pm$ 1) ps FWHM. With LGSO crystals of 2$\times$2$\times$3 mm$^3$, a CTR of (85 $\pm$ 1) ps FWHM. To the best of our knowledge, this is the first time that a CTR below 100 ps using on-chip digitization is reported.

  • Open Access

    Toward Sub-100 ps TOF-PET Systems Employing the FastIC ASIC With Analog SiPMs

    by A. Mariscal-Castilla, S. Gómez, R. Manera, J. M. Fernández-Tenllado, J. Mauricio, N. Kratochwil, J. Alozy, M. Piller, S. Portero, A. Sanuy, et al.

    Time-of-flight positron emission tomography (TOF-PET) scanners demand electronics that are power-efficient, low-noise, cost-effective, and possess a large bandwidth. Recent developments have demonstrated sub-100 ps time resolution with elevated power consumption per channel, rendering this unfeasible to build a scanner. In this work, we evaluate the performance for TOF-PET of the FastIC front-end using different scintillators and silicon photomultipliers (SiPMs). FastIC is an 8-channel ASIC developed in CMOS 65 nm capable of measuring the energy and the arrival time of a detected pulse with 12 mW per channel. Using Hamamatsu SiPMs (S13360-3050PE) coupled to LSO:Ce:0.2%Ca crystals of 2 × 2 × 3 mm and LYSO:Ce:0.2%Ca of 3.13 × 3.13 × 20 mm, we measured a CTR of (95 ± 3) ps and 156 ± 4) ps FWHM, respectively. With FBK NUV-HD LF2 M0 SiPMs coupled to the same crystals, we obtained a CTR of (76 ± 2) ps and (127 ± 3) ps FWHM. We employed FastIC with a TlCl pure Cherenkov emitter, demonstrating time resolutions comparable to those achieved with high-power-consuming electronics. These findings shows that FastIC represents a cost-effective alternative that can significantly enhance the time resolution of current TOF-PET systems while maintaining low power consumption.