JZJieyu Zhu

Jieyu Zhu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jieyu Zhu has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and implementation of an evaluation system for SAMPA ASIC

    by Xin Sun, XiaoLin Xia, Jieyu Zhu, Yangzhou Su, HaoJie Chen, Bianbian Cui, XiangWei Peng, Hao Quan, Longjie Wang, Xiaoyang Niu, et al.

    The transition radiation detector (TRD), a crucial subsystem of the High Energy Cosmic Radiation Detection (HERD) facility, is designed to calibrate the electromagnetic calorimeter at TeV-range energies and to perform X-ray observations as part of all-sky surveys. Multiple SAMPA application-specific integrated circuits (ASICs) are employed in the TRD front-end electronics (FEE). Since the SAMPA is an industrial-grade ASIC, its suitability for aerospace applications remains uncertain, especially concerning its long-term stability and low-noise performance in the space environment. To address this uncertainty, a dedicated evaluation system was developed, consisting of a SAMPA evaluation board and corresponding host computer software. The board integrates two SAMPA test sockets, a Kintex-7 FPGA from AMD, and several communication interfaces. The FPGA provides clock and trigger signals to the SAMPA via differential signal, receives data from the chips through eleven scalable low-voltage signaling (SLVS) high-speed serial links, processes the data, and transmits it to the host computer software. The host computer software enables system control, facilitates real-time and online analysis, and supports the evaluation of critical performance indicators, such as noise and linearity.

  • Development of radiation test system for HERD-TRD COTS chips

    by Xiangwei Peng, Haibo Yang, Huijun Hu, Xin Sun, Chengcheng Liu, Jieyu Zhu, Xiaolin Xia, Junhua Feng, Xiwen Liu, Xushuang Zhang, et al.

    The High Energy Cosmic Radiation Detector (HERD) is scheduled for deployment on the China Space Station in 2029. As a key payload subsystem of HERD, the transition radiation detector (TRD) is designed to support high-precision energy calibration and observations in the TeV energy range. However, the reliability of lower-grade commercial off-the-shelf (COTS) chips used in the TRD has not been fully validated in the space radiation environment, in which single-event effects (SEE) may occur. To address this issue, we propose a modular radiation-hardness evaluation system consisting of a main control board, multiple device-under-test (DUT) boards, and a host computer. Separation between the main control board and the DUT boards enables flexible configuration and rapid evaluation across chip types, while the host computer provides real-time data visualization, remote control of SEE tests, and automatic data archiving for subsequent analysis. This system was used to conduct heavy-ion irradiation tests on key COTS chips used in the TRD. Under a tantalum (Ta) ion beam with LET 75 MeV·cm 2 /mg, no SEE were observed in any tested chip. Based on Poisson statistics, we derived an upper bound on the SEE cross section for the considered chips, σ SEE < 3 × 10 -7 cm 2 /chip @ 95% C.L., supporting the conclusion that these chips exhibit low susceptibility to SEE.The experimental results demonstrate the radiation robustness of the selected TRD chips and validate the reliability of the proposed test system for SEE evaluation in space applications.

  • Performance characterization of the SAMPA ASIC for gaseous detector front-end applications

    by Jieyu Zhu, Haibo Yang, Yangzhou Su, Xiaolin Xia, Bianbian Cui, Chengxin Zhao

    The SAMPA chip is a front-end readout ASIC designed for the Time Projection Chamber (TPC) and Muon Chamber (MCH) in the ALICE experiment. SAMPA features a fast response time, along with excellent time and energy resolution. It offers flexible polarity switching, time shaping, and gain adjustment through configuration, enabling it to meet the requirements of various gas detectors. However, the manual currently recommends only three fixed support configuration modes, while other modes remain unverified. This paper describes the front-end readout electronics of a gas detector designed using the SAMPA chip, with calibration performed for the unverified modes. The system utilizes four SAMPA chips, allowing for 128 channels of detector data acquisition. Test results demonstrate that the system meets the dynamic range requirements across different scenarios, enabling online gain switching for enhanced flexibility in dynamic range and improved energy resolution.

  • Front-End Electronics Design for the Transition Radiation Detector Prototype in the HERD

    by Jieyu Zhu, Haibo Yang, Yangzhou Su, Xiwen Liu, Ran Chen, Hui Wang, Ping Wei, Cong Dai, Haoqing Xie, Hongbang Liu, et al.

    The High Energy Cosmic Radiation Detection Facility (HERD) is a part of the Chinese Cosmic Lighthouse Program in the China Space Station, which has been planned to be launched in 2027. The HERD is expected to operate for ten years in orbit, and it will be able to indirectly detect dark matter, measure cosmic rays, and observe high-energy gamma rays. As a sub-detector of the HERD, a transition radiation detector (TRD) has the main scientific goal of calibrating the electromagnetic calorimeter (CALO) at the TeV energy range, improving the measurement accuracy of the CALO, and detecting astronomical phenomena of high-energy gamma rays. In this work, we designed the front-end electronics (FEE) as a standard readout unit for the TRD prototype in the HERD. The FEE uses four SAMPA ASICs for 128 detector signal readouts, realizing a high-speed, low-power, and high-reliability data acquisition system. The FEE receives trigger signals and serial commands from the back-end electronics (BEE) using the universal asynchronous receiver transmitter (UART) protocol via an RS-422 bus and replies to the BEE, providing appropriate remote environmental and FPGA status parameters. In addition, the FEE sends detector scientific data and clock signals via a low-voltage differential signaling (LVDS) bus at 80 Mbps with a dual-channel hot backup. According to the results of the electrical tests on the electronics, the channel’s Root Mean Square (RMS) noise is less than 1.7 fC, and the linearity is better than 0.2%. In addition, a beam test is performed on the SPS and PS terminals of the CERN to verify the electronic performance of the proposed system. The results show that the proposed FEE can meet the readout requirements of the TRD prototype and can accurately obtain the energy spectrum of muons and electrons.


  • Design of a Common High-Performance Data Acquisition System for Physics Experiments at HIAF

    by Honglin Zhang, Haibo Yang, Chengcheng Liu, Wenchao Sun, Shun Liao, Xianqin Li, Jieyu Zhu, Hu Ran, Chengxin Zhao

    In this paper, a common high-performance data acquisition (DAQ) system for High Intensity heavy-ion Accelerator Facility (HIAF) centered with a new Common Data Aquation Unit (CDAU), is introduced. The system includes eight fiber optic transmission channels connected to front-end electronics, delivering data bandwidth up to 10 Gbps per channel, along with highly scalable Flexible Mezzanine Cards (FMC) and General-Purpose Input/Output (GPlO) interfaces. Moreover, a PCI Express 2.0 ×8 protocol (bandwidth up to 40 Gbps) is implemented to facilitate data exchange with data center. Laboratory characterization revealed that the Bit Error Rate (BER) of the fiber optic transmission channel is relatively low, at 5.8 × 10 −16 at a 10 Gbps transmission rate. Additionally, the read/write rates of the PCIe interface demonstrated stability, with the read speed consistently maintained at 3400 MB/s and an error rate as low as 2.09 × 10 −15 , while the write speed is stable at 3420 MB/s, with an error rate reaching 2.14 × 10 −15 . Subsequent experiments involved measuring 137 Cs radiation source and cosmic ray spectra using various scintillator detectors, achieving the energy resolution of 1.12% and 21.34%. Overall, the data acquisition system proved robust and stable in practical scenarios in HIAF. This paper examines the data acquisition system’s design and performance.


  • Design of the Data Acquisition System for the HERD Transition Radiation Detector Prototype

    by Hui Wang, Dong Wang, Ran Chen, Kai Chen, Muxian Li, Jieyu Zhu, Xiwen Liu, Cong Dai, Fan Jiang, Yangzhou Su, et al.

    The Transition Radiation Detector (TRD) of the High Energy Cosmic Radiation Detection facility (HERD) utilizes the relationship between high-energy charged particle transition radiation and the Lorentz factor to calibrate the energy of TeV-band protons in HERD calorimeters. It can also independently conduct X-ray observation and monitor Gamma-Ray Bursts. The TRD consists of detector units, front-end electronics (FEE), and a data acquisition (DAQ) system. The DAQ system is responsible for the overall power management of the TRD, communication and triggering between the TRD and HERD, data processing of the detector units, control of multiple modules within the TRD, and in-orbit operation of the whole TRD. Here we report a DAQ system of the TRD prototype, which connects six front-end circuit boards, six high-voltage circuit boards, a turntable device, a HERD trigger system, and HERD electronics. It adopts a structure with separate data and electrical components. The power sections of the front-end electronics, high-voltage, turntable device, and DAQ system are designed as a power circuit board, while the FEE data transmission and telemetry, triggering, main controller, storage, and communication are designed as a data circuit board. We tested the DAQ system at the European Organization for Nuclear Research, and the results show that the system can meet the requirements of the TRD prototype in terms of power, communication, data processing, and overall control. Additionally, we demonstrate that the DAQ system has been redundantly designed to enhance adaptability.


  • Prototype Design of Readout Electronics for the Multiple Sampling Ionization Chamber at HIAF-HFRS

    by Haibo Yang, Chengcheng Liu, Shuwen Tang, Fenhua Lu, Shun Liao, Xianqin Li, Jieyu Zhu, Yangzhou Su, Honglin Zhang, Haoqing Xie, et al.

    Nuclear physics using radioactive beams has been the most dynamic research area in nuclear science. A High Intensity Heavy-Ion Accelerator Facility (HIAF) is currently under construction, which includes the installation of a cuttingedge High Energy Fragment Separator (HFRS) with high energy and intensity capabilities. The HFRS uses the magnetic-rigidity-time-of-flight-energy-loss (Bρ-TOF-ΔE) method, which has been commonly used in nuclear fragmentation secondary beam devices to achieve high magnetic rigidity, large ion-optical acceptance, and excellent particle identification. The energy loss (ΔE) detector plays a crucial role in particle identification. The energy loss detector is designed using the multiple sampling ionization chamber (MUSIC) detector. It can significantly improve the energy resolution of the gas ionization chamber through multiple samplings. The prototype of the readout electronics of one MUSIC consists of eight charge-sensitive preamplifiers (CSPs) modules and one readout control electronics (RCE) module. The CSPs placed inside the MUSIC read the MUSIC charge signals. A RCE has eight signal input channels. The RCE receives voltage signal pulses from the CSPs, amplifies, filters, and digitizes the signal. The measured data is packed and transferred to the data acquisition (DAQ) system via a 10-Gb ethernet protocol. The readout electronics have been tested. The test results indicate that the noise performance is better than 0.22 mV (i.e., the root mean square (RMS) error), and the nonlinearity of the entire readout electronics is less than 0.17%. The joint test results of the MUSIC detector show that it has an excellent performance in measuring the radioactive source and heavy-ion beams. This paper will discuss the design and performance of the readout electronics.