Xiaolin Xia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaolin Xia has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Haibo Yang
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
5 shared publications - Bianbian Cui
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
3 shared publications - Jieyu Zhu
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
3 shared publications - Xiangwei Peng
Guangxi Key Laboratory for Relativistic Astrophysics, School of Physical Science and Technology, Guangxi University, Nanning 530004, China
3 shared publications - Xin Sun
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
3 shared publications - Chengxin Zhao
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
2 shared publications
Latest Publications
- Open Access
- 1 February 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (02) , T02007
A low-power front-end readout ASIC for VLAST silicon microstrip detectors
In this paper, we report the development of a low-power, 16-channel front-end readout application-specific integrated circuit (ASIC), named SiReadout-S, designed for the silicon microstrip detectors of the Very Large Area Gamma-ray Space Telescope (VLAST). Each readout channel measures the charge collected by the detector and provides trigger information. Each channel comprises a charge-sensitive amplifier, a leakage current compensation circuit, a polarity selection circuit, a CR-RC shaper, a multiple-feedback (MFB) filter, a sample-and-hold circuit, a discriminator, a time-sequence control circuit, and an output buffer. The SiReadout-S is implemented in a 180 nm mixed-signal CMOS process, and the prototype die measures 3.22 mm × 2.23 mm. For a typical positive charge input configuration, the electrical performance was characterized by an overall gain exceeding 6 mV/fC per channel, a core circuit power consumption of 298 μW per channel, a linearity error of less than 3%, a dynamic range of 220 fC, and a maximum channel-to-channel variation of 6.03%. The equivalent noise charge (ENC) for a typical channel is 671 e - at 0 pF plus 2.8 e - /pF. In integrated tests with a 16-channel silicon microstrip detector, the SiReadout-S test system achieved an energy resolution of 3.86% at the 5.486 MeV energy of 241 Am source.
- 1 February 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (02) , T02007
Open AccessA low-power front-end readout ASIC for VLAST silicon microstrip detectors
In this paper, we report the development of a low-power, 16-channel front-end readout application-specific integrated circuit (ASIC), named SiReadout-S, designed for the silicon microstrip detectors of the Very Large Area Gamma-ray Space Telescope (VLAST). Each readout channel measures the charge collected by the detector and provides trigger information. Each channel comprises a charge-sensitive amplifier, a leakage current compensation circuit, a polarity selection circuit, a CR-RC shaper, a multiple-feedback (MFB) filter, a sample-and-hold circuit, a discriminator, a time-sequence control circuit, and an output buffer. The SiReadout-S is implemented in a 180 nm mixed-signal CMOS process, and the prototype die measures 3.22 mm × 2.23 mm. For a typical positive charge input configuration, the electrical performance was characterized by an overall gain exceeding 6 mV/fC per channel, a core circuit power consumption of 298 μW per channel, a linearity error of less than 3%, a dynamic range of 220 fC, and a maximum channel-to-channel variation of 6.03%. The equivalent noise charge (ENC) for a typical channel is 671 e - at 0 pF plus 2.8 e - /pF. In integrated tests with a 16-channel silicon microstrip detector, the SiReadout-S test system achieved an energy resolution of 3.86% at the 5.486 MeV energy of 241 Am source.
- Open Access
- 1 December 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (12) , P12011
Design and implementation of an evaluation system for SAMPA ASIC
The transition radiation detector (TRD), a crucial subsystem of the High Energy Cosmic Radiation Detection (HERD) facility, is designed to calibrate the electromagnetic calorimeter at TeV-range energies and to perform X-ray observations as part of all-sky surveys. Multiple SAMPA application-specific integrated circuits (ASICs) are employed in the TRD front-end electronics (FEE). Since the SAMPA is an industrial-grade ASIC, its suitability for aerospace applications remains uncertain, especially concerning its long-term stability and low-noise performance in the space environment. To address this uncertainty, a dedicated evaluation system was developed, consisting of a SAMPA evaluation board and corresponding host computer software. The board integrates two SAMPA test sockets, a Kintex-7 FPGA from AMD, and several communication interfaces. The FPGA provides clock and trigger signals to the SAMPA via differential signal, receives data from the chips through eleven scalable low-voltage signaling (SLVS) high-speed serial links, processes the data, and transmits it to the host computer software. The host computer software enables system control, facilitates real-time and online analysis, and supports the evaluation of critical performance indicators, such as noise and linearity.
- 1 December 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (12) , P12011
Open AccessDesign and implementation of an evaluation system for SAMPA ASIC
The transition radiation detector (TRD), a crucial subsystem of the High Energy Cosmic Radiation Detection (HERD) facility, is designed to calibrate the electromagnetic calorimeter at TeV-range energies and to perform X-ray observations as part of all-sky surveys. Multiple SAMPA application-specific integrated circuits (ASICs) are employed in the TRD front-end electronics (FEE). Since the SAMPA is an industrial-grade ASIC, its suitability for aerospace applications remains uncertain, especially concerning its long-term stability and low-noise performance in the space environment. To address this uncertainty, a dedicated evaluation system was developed, consisting of a SAMPA evaluation board and corresponding host computer software. The board integrates two SAMPA test sockets, a Kintex-7 FPGA from AMD, and several communication interfaces. The FPGA provides clock and trigger signals to the SAMPA via differential signal, receives data from the chips through eleven scalable low-voltage signaling (SLVS) high-speed serial links, processes the data, and transmits it to the host computer software. The host computer software enables system control, facilitates real-time and online analysis, and supports the evaluation of critical performance indicators, such as noise and linearity.
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , P11020
Development of radiation test system for HERD-TRD COTS chips
The High Energy Cosmic Radiation Detector (HERD) is scheduled for deployment on the China Space Station in 2029. As a key payload subsystem of HERD, the transition radiation detector (TRD) is designed to support high-precision energy calibration and observations in the TeV energy range. However, the reliability of lower-grade commercial off-the-shelf (COTS) chips used in the TRD has not been fully validated in the space radiation environment, in which single-event effects (SEE) may occur. To address this issue, we propose a modular radiation-hardness evaluation system consisting of a main control board, multiple device-under-test (DUT) boards, and a host computer. Separation between the main control board and the DUT boards enables flexible configuration and rapid evaluation across chip types, while the host computer provides real-time data visualization, remote control of SEE tests, and automatic data archiving for subsequent analysis. This system was used to conduct heavy-ion irradiation tests on key COTS chips used in the TRD. Under a tantalum (Ta) ion beam with LET 75 MeV·cm 2 /mg, no SEE were observed in any tested chip. Based on Poisson statistics, we derived an upper bound on the SEE cross section for the considered chips, σ SEE < 3 × 10 -7 cm 2 /chip @ 95% C.L., supporting the conclusion that these chips exhibit low susceptibility to SEE.The experimental results demonstrate the radiation robustness of the selected TRD chips and validate the reliability of the proposed test system for SEE evaluation in space applications.
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , P11020
Development of radiation test system for HERD-TRD COTS chips
The High Energy Cosmic Radiation Detector (HERD) is scheduled for deployment on the China Space Station in 2029. As a key payload subsystem of HERD, the transition radiation detector (TRD) is designed to support high-precision energy calibration and observations in the TeV energy range. However, the reliability of lower-grade commercial off-the-shelf (COTS) chips used in the TRD has not been fully validated in the space radiation environment, in which single-event effects (SEE) may occur. To address this issue, we propose a modular radiation-hardness evaluation system consisting of a main control board, multiple device-under-test (DUT) boards, and a host computer. Separation between the main control board and the DUT boards enables flexible configuration and rapid evaluation across chip types, while the host computer provides real-time data visualization, remote control of SEE tests, and automatic data archiving for subsequent analysis. This system was used to conduct heavy-ion irradiation tests on key COTS chips used in the TRD. Under a tantalum (Ta) ion beam with LET 75 MeV·cm 2 /mg, no SEE were observed in any tested chip. Based on Poisson statistics, we derived an upper bound on the SEE cross section for the considered chips, σ SEE < 3 × 10 -7 cm 2 /chip @ 95% C.L., supporting the conclusion that these chips exhibit low susceptibility to SEE.The experimental results demonstrate the radiation robustness of the selected TRD chips and validate the reliability of the proposed test system for SEE evaluation in space applications.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , C05012
Performance characterization of the SAMPA ASIC for gaseous detector front-end applications
The SAMPA chip is a front-end readout ASIC designed for the Time Projection Chamber (TPC) and Muon Chamber (MCH) in the ALICE experiment. SAMPA features a fast response time, along with excellent time and energy resolution. It offers flexible polarity switching, time shaping, and gain adjustment through configuration, enabling it to meet the requirements of various gas detectors. However, the manual currently recommends only three fixed support configuration modes, while other modes remain unverified. This paper describes the front-end readout electronics of a gas detector designed using the SAMPA chip, with calibration performed for the unverified modes. The system utilizes four SAMPA chips, allowing for 128 channels of detector data acquisition. Test results demonstrate that the system meets the dynamic range requirements across different scenarios, enabling online gain switching for enhanced flexibility in dynamic range and improved energy resolution.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , C05012
Performance characterization of the SAMPA ASIC for gaseous detector front-end applications
The SAMPA chip is a front-end readout ASIC designed for the Time Projection Chamber (TPC) and Muon Chamber (MCH) in the ALICE experiment. SAMPA features a fast response time, along with excellent time and energy resolution. It offers flexible polarity switching, time shaping, and gain adjustment through configuration, enabling it to meet the requirements of various gas detectors. However, the manual currently recommends only three fixed support configuration modes, while other modes remain unverified. This paper describes the front-end readout electronics of a gas detector designed using the SAMPA chip, with calibration performed for the unverified modes. The system utilizes four SAMPA chips, allowing for 128 channels of detector data acquisition. Test results demonstrate that the system meets the dynamic range requirements across different scenarios, enabling online gain switching for enhanced flexibility in dynamic range and improved energy resolution.