BCByunghoon Chung

Byunghoon Chung

*This is an algorithmically generated author record based on publicly available information.

Byunghoon Chung has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Decentration measurements using Placido corneal tangential curvature topography and Scheimpflug tomography pachymetry difference maps after small-incision lenticule extraction

    by Byunghoon Chung, Hun Lee, Cynthia J. Roberts, David Sung Yong Kang, Dan Z. Reinstein, Seung Ki Jean, Eung Kweon Kim, Kyoung Yul Seo, Tae-Im Kim

    To assess the agreement of decentration measurements between tangential curvature topography and tomography pachymetry difference maps after a small-incision lenticule extraction (SMILE) procedure. Yonsei University College of Medicine and Eyereum Eye Clinic, Seoul, South Korea. Retrospective case series. Decentrations and pupillary offset (angle κ) were analyzed and compared using two different methods. A difference map of the tangential curvature was generated with a Placido corneal topographer (Keratron Scout) and a pachymetry difference map was generated with a Scheimpflug tomographer (Pentacam) for each eye, using preoperative and 3-month postoperative scans. Decentrations were also compared using a vector difference plot for the two maps. The study comprised 155 eyes (155 patients). The magnitude of decentration was 0.27 mm ± 0.17 (SD) (range 0.02 to 0.88 mm) with the tangential curvature difference maps and 0.26 ± 0.20 mm (range 0.00 to 0.91 mm) with the pachymetry difference maps, showing no significant difference in the arithmetic values of decentration (P = .124). However, the vector difference in pupillary offset between preoperative and postoperative measurements from the pachymetry difference map significantly correlated with the magnitude of vector differences of decentration between the two maps (P = .007). The vector difference plot also showed a wide distribution spread to all 4 quadrants, demonstrating a lack of agreement. Although there was no significant difference between the scalar magnitude of decentration with the tangential topography difference maps and tomography pachymetry difference maps, the vector differences did not agree and increasing error was present with increasing differences in pupillary offset in the pachymetry difference maps.


  • Anti–Vascular Endothelial Growth Factor with Gas for Submacular Hemorrhage

    by Joo Youn Shin, Hun Jin Choi, Byunghoon Chung, Moonjung Choi, Jonghyun Lee, Suk Ho Byeon

    Purpose: To investigate the treatment outcome of pneumatic displacement and intravitreal anti–vascular endothelial growth factor (VEGF) for submacular hemorrhage (SMH) from exudative age‐related macular degeneration (AMD). Methods: Best‐corrected visual acuity (BCVA) and central foveal thickness (CFT) were measured at baseline and at 1, 3, and 6 months after initial treatment in 72 eyes of 72 patients treated with a combination of pneumatic displacement and anti‐VEGF injection for SMH from exudative AMD. Results: Best‐corrected visual acuity and CFT showed significant improvement from baseline during the 6‐month follow‐up period (logarithm of the minimum angle of resolution BCVA from 1.80 to 1.00, CFT from 886 to 383 μm, p < 0.001, respectively). The decrease in subretinal hemorrhage was greater than that in subretinal pigment epithelial hemorrhage at 1 month after initial treatment (p < 0.001). In eyes with symptoms for less than 30 days, higher reflectivity of hemorrhage on optical coherence tomography and higher CFT were associated with lower BCVA after 6 months of treatment (reflectivity B = 0.335, p = 0.007; CFT B = 0.001, p = 0.003). Conclusions: The combination of pneumatic displacement and intravitreal anti‐VEGF is a useful treatment option for SMH secondary to AMD. Higher baseline CFT and higher reflectivity of hemorrhage were associated with lower BCVA 6 months after initial treatment.


  • Comparison of Measurements and Clinical Outcomes After Wavefront-Guided LASEK Between iDesign and WaveScan

    by Ji Won Jung, Byung Hoon Chung, Sun Hyup Han, Eung Kweon Kim, Kyoung Yul Seo, Tae-Im Kim

    Original Article Ji Won Jung, MD; Byung Hoon Chung, MD; Sun Hyup Han, BA; Eung Kweon Kim, MD, PhD; Kyoung Yul Seo, MD, PhD; Tae-im Kim, MD, PhD To compare the measurements of refractive errors and ocular aberrations obtained using iDesign and WaveScan (Abbott Medical Optics, Inc., Santa Ana, CA), and to compare surgical outcomes of wavefront-guided LASEK using ablation profiles based on both aberrometers. Ninety myopic eyes of 45 normal patients were evaluated using both the iDesign and WaveScan to measure spherical and cylindrical errors, spherical equivalents, and Zernike coefficients of ocular aberrations. Wavefront-guided LASEK was performed in a different group of 59 eyes of 30 patients divided into two groups, the iDesign and Wavescan groups. The clinical outcomes between the two groups including uncorrected visual acuity, refractive errors, contrast sensitivity, and ocular aberration were compared at 1, 3, and 6 months postoperatively. The iDesign produced significantly higher myopic values for refractive errors than the WaveScan, as well as significantly lower levels of total higher order, third, fourth, and fifth order root mean square values and Zernike coefficients of vertical coma and spherical aberration. At postoperative 1, 3, and 6 months, there were no statistically significant differences between the two groups in terms of uncorrected visual acuity and remaining refractive errors. The percentages of patients with spherical equivalents within ±1.00 and ±0.50 diopters of emmetropia were 100% (29 eyes) and 75.9% (22 eyes), respectively, in the iDesign group and 96.7% (29 eyes) and 70.0% (21 eyes), respectively, in the WaveScan group. Mesopic contrast sensitivity values were significantly higher, and the change in root mean square values for spherical aberration was significantly lower in the iDesign group. There were significant differences between the iDesign and the WaveScan in the measurements of refraction and ocular aberrations. Wavefront-guided LASEK based on an ablation profile from the iDesign demonstrated comparable refractive predictability with the WaveScan group, resulting in minimal physician adjustment and superior postoperative visual quality. [J Refract Surg. 2015;31(6):398–405.] From the Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea (JWJ, BHC, SHH, EKK, KYS, TIK); the Department of Ophthalmology and Inha Vision Science Laboratory, Inha University School of Medicine, Incheon, South Korea (JWJ); and the Corneal Dystrophy Research Institute, Severance Biomedical Science Institute, and Brain Korea 21 Plus Project for Medical Science, Yonsei University College of Medicine, Seoul, South Korea (EKK). The authors have no financial or proprietary interest in the materials presented herein. Supported in part by a grant from the Korean Health Technology R & D Project, Ministry of Health & Welfare, Republic of Korea (HI14C2044) and the Basic Science Research Program through the National Research Foundation of Korea funded by the Ministry of Education, Science, and Technology (2013R1A1A2058907). AUTHOR CONTRIBUTIONS Study concept and design (JWJ, TIK); data collection (JWJ, BHC); analysis and interpretation of data (JWJ, EKK, KYS, TIK); writing the manuscript (JWJ, TIK); critical revision of the manuscript (JWJ, EKK, KYS, TIK); statistical expertise (JWJ); administrative, technical, or material support (SHH); supervision (TIK) Correspondence: Tae-im Kim, MD, PhD, Department of Ophthalmology, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, South Korea, 120-752. E-mail: tikim@yuhs.ac To compare the measurements of refractive errors and ocular aberrations obtained using iDesign and WaveScan (Abbott Medical Optics, Inc., Santa Ana, CA), and to compare surgical outcomes of wavefront-guided LASEK using ablation profiles based on both aberrometers. Ninety myopic eyes of 45 normal patients were evaluated using both the iDesign and WaveScan to measure spherical and cylindrical errors, spherical equivalents, and Zernike coefficients of ocular aberrations. Wavefront-guided LASEK was performed in a different group of 59 eyes of 30 patients divided into two groups, the iDesign and Wavescan groups. The clinical outcomes between the two groups including uncorrected visual acuity, refractive errors, contrast sensitivity, and ocular aberration were compared at 1, 3, and 6 months postoperatively. The iDesign produced significantly higher myopic values for refractive errors than the WaveScan, as well as significantly lower levels of total higher order, third, fourth, and fifth order root mean square values and Zernike coefficients of vertical coma and spherical aberration. At postoperative 1, 3, and 6 months, there were no statistically significant differences between the two groups in terms of uncorrected visual acuity and remaining refractive errors. The percentages of patients with spherical equivalents within ±1.00 and ±0.50 diopters of emmetropia were 100% (29 eyes) and 75.9% (22 eyes), respectively, in the iDesign group and 96.7% (29 eyes) and 70.0% (21 eyes), respectively, in the WaveScan group. Mesopic contrast sensitivity values were significantly higher, and the change in root mean square values for spherical aberration was significantly lower in the iDesign group. There were significant differences between the iDesign and the WaveScan in the measurements of refraction and ocular aberrations. Wavefront-guided LASEK based on an ablation profile from the iDesign demonstrated comparable refractive predictability with the WaveScan group, resulting in minimal physician adjustment and superior postoperative visual quality. [J Refract Surg. 2015;31(6):398–405.] From the Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea (JWJ, BHC, SHH, EKK, KYS, TIK); the Department of Ophthalmology and Inha Vision Science Laboratory, Inha University School of Medicine, Incheon, South Korea (JWJ); and the Corneal Dystrophy Research Institute, Severance Biomedical Science Institute, and Brain Korea 21 Plus Project for Medical Science, Yonsei University College of Medicine, Seoul, South Korea (EKK). The authors have no financial or proprietary interest in the materials presented herein. Supported in part by a grant from the Korean Health Technology R & D Project, Ministry of Health & Welfare, Republic of Korea (HI14C2044) and the Basic Science Research Program through the National Research Foundation of Korea funded by the Ministry of Education, Science, and Technology (2013R1A1A2058907). AUTHOR CONTRIBUTIONS Study concept and design (JWJ, TIK); data collection (JWJ, BHC); analysis and interpretation of data (JWJ, EKK, KYS, TIK); writing the manuscript (JWJ, TIK); critical revision of the manuscript (JWJ, EKK, KYS, TIK); statistical expertise (JWJ); administrative, technical, or material support (SHH); supervision (TIK) Correspondence: Tae-im Kim, MD, PhD, Department of Ophthalmology, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, South Korea, 120-752. E-mail: tikim@yuhs.ac 10.3928/1081597X-20150521-06


  • Pigment epithelial tears after ranibizumab injection in polypoidal choroidal vasculopathy and typical age-related macular degeneration

    by Joo Youn Shin, Moonjung Choi, Byunghoon Chung, Suk Ho Byeon

    The purpose of the study was to compare the rates and characteristics of retinal pigment epithelial (RPE) tears between typical exudative age-related macular degeneration (tAMD) and polypoidal choroidal vasculopathy (PCV) after injection of intravitreal ranibizumab (IVR). In total, 836 eyes from 784 patients with exudative AMD treated with IVR were analyzed. The presence, type, size, and height of pigment epithelial detachment (PED) in OCT before injection were evaluated, and the occurrence rate of RPE tears within three months of injection between tAMD and PCV was compared. In total, 515 eyes (61.6 %) had tAMD and 321 eyes (38.4 %) were diagnosed as PCV. RPE tears developed in 18 eyes (3.5 %) in the tAMD group, while only two eyes (0.62 %) were associated with PCV (p = 0.009, Chi-square test). Eleven of the eighteen eyes with RPE tears in tAMD had fibrovascular PED with contractile neovascular tissue under the surface of the RPE and a cleft at baseline. Two eyes with RPE tears in PCV showed large hemorrhagic PED before presenting with an RPE tear. RPE tears after IVR were significantly less common in PCV than in tAMD. The different characteristics of RPE tears between the two disease entities suggest differences in the pathogenesis underlying the event.