TLThe Khanh Lai

The Khanh Lai

*This is an algorithmically generated author record based on publicly available information.

The Khanh Lai has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Ich Long Ngo

    School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam

    3 shared publications
  • Minh Duc Nguyen

    School of Mechanical Engineering, HUST 1 , No. 01, Dai Co Viet, Hai Ba Trung, Hanoi, Vietnam

    1 shared publication
  • Thi Anh Nguyen

    \(^3\) chool of Electrical and Electronic Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet, Hanoi, Vietnam

    1 shared publication
  • Toan Dinh

    School of Engineering University of Southern Queensland Springfield Central Queensland Australia

    1 shared publication
  • Toan Thang Vu

    \(^1\) School of Mechanical Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet, Hanoi, Vietnam

    1 shared publication
  • Van Tran Do

    \(^1\) School of Mechanical Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet, Hanoi, Vietnam \(^2\) Faculty of Mechanical Engineering, University of Transport and Communications, No. 3 Cau Giay, Hanoi, Vietnam

    1 shared publication

Latest Publications

  • A Comprehensive Study on Improving the Electrohydrodynamic Performance of Electroconjugate Fluid Micropumps Using Hydrodynamic-Shaped Electrodes

    by The Khanh Lai, Ich Long Ngo

    A novel design of an electroconjugate fluid (ECF) micropump with hydrodynamic-shaped electrodes was proposed in this study. The finite element method was employed to comprehensively investigate the dynamic behavior of ECF flow in this micropump under various conditions, including electrode types, applied voltage (Ve), the anode–cathode distance (Lc*), the slit width (Ws*), and the cathode width (Wn*). Consequently, the ECF micropump's operating range and efficiency are significantly improved using a hydrodynamic-shaped electrode compared to conventional electrodes. Furthermore, this study first proposes a generalized correlation to effectively predict the maximum pressure difference, revealing that it obeys the quadratic law of Ve. The performance curves of the novel ECF micropump under the effects of various designed parameters are elaborately constructed. Based on an extensive study, the optimum range of these parameters is proposed as 2.85 ≤ Lc* ≤ 3.15, 1.71 ≤ Ws* ≤ 1.89, and 3.33 ≤ Wn* ≤ 3.68. Particularly, the remarkable efficiency is up to 30%. This significant improvement addresses the historically low efficiency of the ECF micropump, opening up new possibilities for its application in industries demanding high performance and efficient fluid control systems.

  • Open Access

    Numerical investigation of electro-conjugate fluid micro-pump under the effects of downstream angle and the negative electrode width

    by Van Tran Do, The Khanh Lai, Toan Thang Vu, Thi Anh Nguyen, Ich Long Ngo

    This paper describes a numerical study of the electro-hydrodynamic behaviors of the fluid flow in an electro-conjugate fluid (ECF) micro-pump under the effects of the collector electrode width (Lc) and its downstream angle (α2). The finite element method was used to examine the characteristics of the ECF micro-pump with the applied voltage ranging from 2 kV to 8 kV, Lc ranging from 0.0 to 4.0, and α2 ranging from 30º to 90º. Consequently, the numerical results indicated that the ECF flow characteristics and the operating ranges of this ECF micro-pump are affected significantly by α2 and Lc of the negative electrode. Indeed, the operating range of the ECF micro-pump can be further extended by reducing α2, particularly at higher flow rates. Moreover, the operating ranges of both pressure difference (∆p) and flow rate of the ECF micro-pump can be extended when Lc varies in the optimum range, i.e., from 0.5 to 2.0. The maximum efficiency of such an ECF micro-pump was 7.4% at φ0 = 8 kV and Lc = 2.0. These results play a critical role in understanding the electro-hydrodynamic behaviors of the fluid flow in an ECF micro-pump, and they can be applied in mechanical and biomedical engineering fields.

  • A new design of electro-conjugate fluid micropumps with Venturi and teardrop-shaped electrodes

    by The Khanh Lai, Toan Dinh, Minh Duc Nguyen, Ich Long Ngo

    This paper presents a newly designed non-mechanical electro-conjugate fluid (ECF) micropump with a Venturi-shaped collector and teardrop-shaped emitter (VD-ECF micropump). The numerical model using the finite element method was thoroughly validated by comparing it with both experimental data and numerical results. Consequently, the characteristic curves of the VD-ECF micropump are significantly affected by both the emitter angle (θ1) and the collector angle (θ2). The effects of these angles on the flow behaviors in a VD-ECF micropump were first explained. Furthermore, the performance characteristic curves were elaborately constructed for various operating conditions. The operating ranges of pressure difference and flow rate of the VD-ECF micropump are extended, and they peak at θ2 approximately from 25° to 30°. Additionally, the maximum efficiency reaches up to 10%, which is the highest figure recorded to date. The obtained results for the new VD-ECF micropump would significantly contribute to the development of ECF micropumps with precise control. Our work also gives valuable guidelines for designing and manufacturing processes of this type of micropump, which has potential applications in microelectronic cooling systems, micro-actuators, and drug transport mechanisms in medical and biomedical fields.