Qin Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qin Gao has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Huanhuan Yang
Dispatching Control Center, China Southern Power Grid, Guangzhou 501699, China
2 shared publications - Jianxin Zhang
Dispatching Control Center, China Southern Power Grid, Guangzhou 501699, China
2 shared publications - Chunxiao Liu
China Southern Power Dispatching and Control Center, Guangzhou 510663, China
1 shared publication - Guanghu Xu
The Power Dispatching and Control Center, China Southern Power Grid, Guangzhou 510623, China
1 shared publication - Jian Qiu
Power Dispatching Control Center, China Southern Power Grid, Guangzhou 510663, China
1 shared publication Jun An
Northeast Electric Power University
1 shared publication
Latest Publications
- 6 January 2026
- Published by Springer Nature
- p. 25-32
Evaluation Method of Stable Response Effectiveness of Control System for Wind Power Frequency Regulation
- 6 January 2026
- Published by Springer Nature
- p. 25-32
Evaluation Method of Stable Response Effectiveness of Control System for Wind Power Frequency Regulation
- Open Access
Coordinated Control of Transient Voltage Support in Doubly Fed Induction Generators
The large-scale integration of wind power significantly alters the voltage dynamic characteristics of power systems. Wind turbines have a weak ability to withstand grid disturbances and have difficulty in providing effective reactive power support during transient periods. The sensitivity of wind turbines to the grid voltage significantly increases the probability of large-scale, cascading off-grid events. This paper proposes a coordinated control strategy to enhance the transient reactive power support capability of doubly fed wind farms. The additional stator current demagnetization control reduces the risk of a crowbar protection action after a fault and ensures that the unit power is controllable. Based on the voltage–reactive power coupling relationship, each unit can produce reactive power according to the voltage–reactive power sensitivity matrix during the transient period. After the reactive power output of the unit reaches the limit, transient active and reactive combined control is further adopted to reduce the active power output of the unit to a certain extent and improve the reactive power support capability. Finally, two cases are built in the PSCAD to verify the effectiveness of the proposed control strategy. The results show that the proposed control strategy can enable the wind farm to output more reactive power to the grid during the transient period, effectively supporting the system voltage during the transient process and avoiding further deterioration of the fault.
Open AccessCoordinated Control of Transient Voltage Support in Doubly Fed Induction Generators
The large-scale integration of wind power significantly alters the voltage dynamic characteristics of power systems. Wind turbines have a weak ability to withstand grid disturbances and have difficulty in providing effective reactive power support during transient periods. The sensitivity of wind turbines to the grid voltage significantly increases the probability of large-scale, cascading off-grid events. This paper proposes a coordinated control strategy to enhance the transient reactive power support capability of doubly fed wind farms. The additional stator current demagnetization control reduces the risk of a crowbar protection action after a fault and ensures that the unit power is controllable. Based on the voltage–reactive power coupling relationship, each unit can produce reactive power according to the voltage–reactive power sensitivity matrix during the transient period. After the reactive power output of the unit reaches the limit, transient active and reactive combined control is further adopted to reduce the active power output of the unit to a certain extent and improve the reactive power support capability. Finally, two cases are built in the PSCAD to verify the effectiveness of the proposed control strategy. The results show that the proposed control strategy can enable the wind farm to output more reactive power to the grid during the transient period, effectively supporting the system voltage during the transient process and avoiding further deterioration of the fault.