Juan Jose Bonaparte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Juan Jose Bonaparte has a total of 159 co-authors. Here are the top co-authors by number of shared publications:
- Matias Rolf Hampel
Instituto de Tecnologías en Detección y Astropartículas (CNEA, CONICET, UNSAM), Buenos Aires
4 shared publications - Nahuel Müller
Instituto de Tecnologas en Deteccin y Astropartculas (ITeDA), Buenos Aires, Argentina
4 shared publications - Sebastian Kempf
Karlsruher Institut fr Technologie, Karlsruhe, Germany
4 shared publications - Alan Fuster
Instituto de Tecnologías en Detección y Astropartículas (CNEA, CONICET, UNSAM), Buenos Aires, Argentina
3 shared publications - J. D. Bonilla Neira
Instituto de Tecnologas en Deteccin y Astropartculas (ITeDA), Buenos Aires, Argentina
3 shared publications - Luciano Ferreyro
Instituto de Tecnologas en Deteccin y Astropartculas (ITeDA), Buenos Aires, Argentina
3 shared publications
Latest Publications
- 20 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 2300306
Toward a Superconducting Magnetic Thermal Modulator for Bolometric Detectors
We present the preliminary development and characterization of a superconducting thermal switch designed to modulate the thermal response of cryogenic bolometers. The device uses an aluminum thermal link whose conductance is modulated by a niobium control coil. Initial measurements confirm the feasibility of the switching principle and demonstrate dynamic operation at least up to 50 kHz. These early results indicate that this approach can shift the signal spectrum away from 1/f noise, with ongoing efforts focused on integration with bolometric sensors and optimizing device geometry.
- 20 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 2300306
Toward a Superconducting Magnetic Thermal Modulator for Bolometric Detectors
We present the preliminary development and characterization of a superconducting thermal switch designed to modulate the thermal response of cryogenic bolometers. The device uses an aluminum thermal link whose conductance is modulated by a niobium control coil. Initial measurements confirm the feasibility of the switching principle and demonstrate dynamic operation at least up to 50 kHz. These early results indicate that this approach can shift the signal spectrum away from 1/f noise, with ongoing efforts focused on integration with bolometric sensors and optimizing device geometry.
- 25 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
Josephson Arbitrary Waveform Synthesizer for Flux-Ramp Modulation in Microwave SQUID Multiplexers
Microwave SQUID multiplexers (μMUX) have become a key technology for the readout of large arrays of low-temperature detectors, particularly in cosmic microwave background experiments. A critical element of this technique is the flux-ramp modulation signal, whose noise, especially at low frequencies, directly limits the readout performance. This work proposes and experimentally demonstrates the use of a Josephson Arbitrary Waveform Synthesizer (JAWS) as a low-noise, high precision source for generating the sawtooth-shaped flux-ramp signal required in μMUX readout systems. The JAWS, based on the AC Josephson effect, provides intrinsically quantized and spectrally pure waveforms with excellent signal-to-noise ratio. The operation of a 9000-junction JAWS array is characterized and integrated with a cryogenic μMUX device and a custom SDR-based readout system. With this setup, the noise floor level around the harmonic typically used for phase demodulation of the SQUID signal to recover the detector signal was −104dBc/Hz, and the signal-to-noise ratio of this harmonic was 73dB. These results demonstrate the feasibility of using JAWS-based waveform synthesis for μMUX flux-ramp generation.
- 25 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
Josephson Arbitrary Waveform Synthesizer for Flux-Ramp Modulation in Microwave SQUID Multiplexers
Microwave SQUID multiplexers (μMUX) have become a key technology for the readout of large arrays of low-temperature detectors, particularly in cosmic microwave background experiments. A critical element of this technique is the flux-ramp modulation signal, whose noise, especially at low frequencies, directly limits the readout performance. This work proposes and experimentally demonstrates the use of a Josephson Arbitrary Waveform Synthesizer (JAWS) as a low-noise, high precision source for generating the sawtooth-shaped flux-ramp signal required in μMUX readout systems. The JAWS, based on the AC Josephson effect, provides intrinsically quantized and spectrally pure waveforms with excellent signal-to-noise ratio. The operation of a 9000-junction JAWS array is characterized and integrated with a cryogenic μMUX device and a custom SDR-based readout system. With this setup, the noise floor level around the harmonic typically used for phase demodulation of the SQUID signal to recover the detector signal was −104dBc/Hz, and the signal-to-noise ratio of this harmonic was 73dB. These results demonstrate the feasibility of using JAWS-based waveform synthesis for μMUX flux-ramp generation.
- Open Access
- 19 September 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 136 (11)
Optimal demodulation domain for microwave SQUID multiplexers in presence of readout system noise
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of low-temperature detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold- and warm-readout electronic systems used to read it out, as well as the demodulation domain and parameters chosen. In order to understand the impact of the readout systems in the overall detection system noise performance, first, we extended the available μMUX simulation frameworks, including additive and multiplicative noise sources in the probing tones (i.e., phase and amplitude noise), along with the capability of demodulating the scientific data, either in the resonator’s phase or the scattering amplitude. Then, considering the additive noise as a dominant noise source, the optimum readout parameters to achieve minimum system noise were found for both open-loop and flux-ramp demodulation schemes in the aforementioned domains. Later, we evaluated the system noise sensitivity to multiplicative noise sources under the optimum readout parameters. Finally, as a case study, we evaluated the optimal demodulation domain and the expected system noise level for a typical software-defined radio readout system. This work leads to an improved system performance prediction and noise engineering based on the available readout electronics and the selected demodulation domain.
- 19 September 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 136 (11)
Open AccessOptimal demodulation domain for microwave SQUID multiplexers in presence of readout system noise
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of low-temperature detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold- and warm-readout electronic systems used to read it out, as well as the demodulation domain and parameters chosen. In order to understand the impact of the readout systems in the overall detection system noise performance, first, we extended the available μMUX simulation frameworks, including additive and multiplicative noise sources in the probing tones (i.e., phase and amplitude noise), along with the capability of demodulating the scientific data, either in the resonator’s phase or the scattering amplitude. Then, considering the additive noise as a dominant noise source, the optimum readout parameters to achieve minimum system noise were found for both open-loop and flux-ramp demodulation schemes in the aforementioned domains. Later, we evaluated the system noise sensitivity to multiplicative noise sources under the optimum readout parameters. Finally, as a case study, we evaluated the optimal demodulation domain and the expected system noise level for a typical software-defined radio readout system. This work leads to an improved system performance prediction and noise engineering based on the available readout electronics and the selected demodulation domain.
- Open Access
Suitability of Magnetic Microbolometers based on Paramagnetic Temperature Sensors for CMB Polarization Measurements
High resolution maps of polarization anisotropies of the Cosmic Microwave Background (CMB) are in high demand, since the discovery of primordial B-Modes in the polarization patterns would confirm the inflationary phase of the Universe that would have taken place before the last scattering of the CMB at the recombination epoch. Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) are the predominant detector technologies of cryogenic detector array based CMB instruments that search for primordial B-Modes. In this paper we propose another type of cryogenic detector to be used for CMB survey: A magnetic microbolometer (MMB) that is based on a paramagnetic temperature sensor. It is an adaption of state-of-the-art metallic magnetic calorimeters (MMCs) that are meanwhile a key technology for high resolution $\alpha$, $\beta$, $\gamma$ and X-ray spectroscopy as well as the study of neutrino mass. The effort to adapt MMCs for CMB surveys is triggered by their lack of Johnson noise associated with the detector readout, the possibility of straightforward calibration and higher dynamic range given it possesses a broad and smooth responsivity dependence with temperature and the absence of Joule dissipation which simplifies the thermal design. A brief proof of concept case study is analyzed, taking into account typical constraints in CMB measurements and reliable microfabrication processes. The results show that MMBs provide a promising technology for CMB polarization survey as their sensitivity can be tuned for background limited detection of the sky while simultaneously maintaining a low time response to avoid distortion of the point-source response of the telescope. As the sensor technology and its fabrication techniques are compatible with TES based bolometric detector arrays, a change of detector technology would even come with very low cost.Open AccessSuitability of Magnetic Microbolometers based on Paramagnetic Temperature Sensors for CMB Polarization Measurements
High resolution maps of polarization anisotropies of the Cosmic Microwave Background (CMB) are in high demand, since the discovery of primordial B-Modes in the polarization patterns would confirm the inflationary phase of the Universe that would have taken place before the last scattering of the CMB at the recombination epoch. Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) are the predominant detector technologies of cryogenic detector array based CMB instruments that search for primordial B-Modes. In this paper we propose another type of cryogenic detector to be used for CMB survey: A magnetic microbolometer (MMB) that is based on a paramagnetic temperature sensor. It is an adaption of state-of-the-art metallic magnetic calorimeters (MMCs) that are meanwhile a key technology for high resolution $\alpha$, $\beta$, $\gamma$ and X-ray spectroscopy as well as the study of neutrino mass. The effort to adapt MMCs for CMB surveys is triggered by their lack of Johnson noise associated with the detector readout, the possibility of straightforward calibration and higher dynamic range given it possesses a broad and smooth responsivity dependence with temperature and the absence of Joule dissipation which simplifies the thermal design. A brief proof of concept case study is analyzed, taking into account typical constraints in CMB measurements and reliable microfabrication processes. The results show that MMBs provide a promising technology for CMB polarization survey as their sensitivity can be tuned for background limited detection of the sky while simultaneously maintaining a low time response to avoid distortion of the point-source response of the telescope. As the sensor technology and its fabrication techniques are compatible with TES based bolometric detector arrays, a change of detector technology would even come with very low cost. - Open Access
- 9 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10708, 107083V-130
Thermal architecture for the QUBIC cryogenic receiver
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
- 9 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10708, 107083V-130
Open AccessThermal architecture for the QUBIC cryogenic receiver
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.