Mohammad Javad Nasiri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mohammad Javad Nasiri has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Michał Jasiński
Wrocaw University of Science and Technology,Wrocaw,Poland
2 shared publications - Omid Homaee
Department of Electrical Engineering Fundamentals, Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
2 shared publications - Zbigniew Leonowicz
Department of Electrical Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
2 shared publications Ahmad Gholami
Department of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran
1 shared publication- Arsalan Najafi
Department of Electrical Engineering Fundamentals, Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
1 shared publication
Latest Publications
- 11 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (5) , 7303-7313
Lightning Transients in Wind Turbines: A Study on How to Segmentize the Tower, Blades, and Grounding Rods
Segmenting Wind Turbine's (WT) tower and blades has been widely used to increase the accuracy of lightning transient simulations. However, the impact of segmentation on precision and the optimal number of segments required for a specific accuracy level have not been thoroughly investigated. In this paper, at first, a formulation for calculating the characteristic impedance of blades' down conductors is analytically derived and verified based on the experimental data. Then, the electrical parameters of the WT's blades, as nonuniform transmission lines, are accurately calculated. A comprehensive analysis is then performed to examine how the number of segments in WT's blades, tower, and grounding systems affects transient voltages and currents created by lightning strikes. The investigation focuses on assessing the effects of the number of segments in terms of the generated overvoltage across various components, the Ground Potential Rise (GPR) values, and the energy absorbed by Surge Arresters (SA). The numerical studies reveal that the quantity of segments for each component significantly influences the outcomes of the lightning strike. For instance, the number of tower's segments mostly affects the overvoltage at the generator's terminal, while the number of ground's horizontal rod segments has the most impact on GPR. This study provides valuable insights into tailoring segmentation strategies for WT components, paving the way for more effective lightning protection simulation and design.
- 11 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (5) , 7303-7313
Lightning Transients in Wind Turbines: A Study on How to Segmentize the Tower, Blades, and Grounding Rods
Segmenting Wind Turbine's (WT) tower and blades has been widely used to increase the accuracy of lightning transient simulations. However, the impact of segmentation on precision and the optimal number of segments required for a specific accuracy level have not been thoroughly investigated. In this paper, at first, a formulation for calculating the characteristic impedance of blades' down conductors is analytically derived and verified based on the experimental data. Then, the electrical parameters of the WT's blades, as nonuniform transmission lines, are accurately calculated. A comprehensive analysis is then performed to examine how the number of segments in WT's blades, tower, and grounding systems affects transient voltages and currents created by lightning strikes. The investigation focuses on assessing the effects of the number of segments in terms of the generated overvoltage across various components, the Ground Potential Rise (GPR) values, and the energy absorbed by Surge Arresters (SA). The numerical studies reveal that the quantity of segments for each component significantly influences the outcomes of the lightning strike. For instance, the number of tower's segments mostly affects the overvoltage at the generator's terminal, while the number of ground's horizontal rod segments has the most impact on GPR. This study provides valuable insights into tailoring segmentation strategies for WT components, paving the way for more effective lightning protection simulation and design.
- 25 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5352-5362
Analyzing the Effect of Lightning Channel Impedance on the Lightning Overvoltages in Wind Turbines
Lightning is a natural phenomenon that can cause serious damage to power systems including wind farms. Wind Turbines (WTs) are tall structures and are often installed in areas with high lightning activity levels which makes them exposed to direct strikes. One of the parameters affecting the performance of the lightning protection system is the impedance of the lightning channel. In this paper, the effects of this impedance on the lightning overvoltages in wind turbines, and the energy absorbed by Surge Arresters (SAs), as the main lightning protection device, are investigated. The case study is carried out on a WT with 2 MVA of rated power where a direct lightning strike with a maximum current magnitude of 50 kA is struck to one of the WT's blades. Accurate models, designed for transient studies, are used for modeling different parts of the WT. The results of different scenarios are compared, and it is shown that as the value of lightning channel impedance gets higher, the overvoltage caused by the corresponding lightning strike, with the same current magnitude, increases too. In addition, it is shown that the higher the lightning channel impedance, the higher the absorbed energy by the arrester. This shows the importance of the lightning channel impedance's effect on high-voltage studies of WTs, as it can help in selecting proper lightning protection devices.
- 25 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5352-5362
Analyzing the Effect of Lightning Channel Impedance on the Lightning Overvoltages in Wind Turbines
Lightning is a natural phenomenon that can cause serious damage to power systems including wind farms. Wind Turbines (WTs) are tall structures and are often installed in areas with high lightning activity levels which makes them exposed to direct strikes. One of the parameters affecting the performance of the lightning protection system is the impedance of the lightning channel. In this paper, the effects of this impedance on the lightning overvoltages in wind turbines, and the energy absorbed by Surge Arresters (SAs), as the main lightning protection device, are investigated. The case study is carried out on a WT with 2 MVA of rated power where a direct lightning strike with a maximum current magnitude of 50 kA is struck to one of the WT's blades. Accurate models, designed for transient studies, are used for modeling different parts of the WT. The results of different scenarios are compared, and it is shown that as the value of lightning channel impedance gets higher, the overvoltage caused by the corresponding lightning strike, with the same current magnitude, increases too. In addition, it is shown that the higher the lightning channel impedance, the higher the absorbed energy by the arrester. This shows the importance of the lightning channel impedance's effect on high-voltage studies of WTs, as it can help in selecting proper lightning protection devices.